{"id":"BATCH2-006-S00513","document_id":"BATCH2-006","ordinal":513,"source_page":498,"title":"10 - 98","words":699,"text":"10 - 98 \nAny particles created by the sanding process should now be washed off the plates.  This can be done with clean \ntap water (not city water though, due to all the chlorine and other chemicals added), but only use distilled water for \nthe final rinse. \n\nA point which is often missed by people constructing electrolysers is the fact that electrolysis is not just an \nelectrical process, but it is also a magnetic process.  It is important for maximum operating efficiency that the \nplates are aligned magnetically.  This will not be the case when the plates arrive from the supplier as each plate \nwill have random magnetic characteristics.  In theory, stainless steel is not magnetic, in practice that is not always \nthe case.  The easiest way to deal with this situation is to give the plates a mild magnetic orientation.  This can be \ndone quite simply by wrapping a few turns of wire around the stack of plates and passing some brief pulses of DC \ncurrent through the wire.  If your plates are perfect and non-magnetic, then this process will have no effect, but it \nhas been reported that some people have gained improved performance by doing this very simple process \n\nObviously, the plates need to be kept in the same direction when being slotted into the case.  The next step in the \npreparation process is to make up a weak solution of sodium hydroxide.  This is done by adding small amounts of \nthe sodium hydroxide to water held in a container.  The container must not be glass as most glass containers are \nmade from glass of insufficient quality to allow mixing of electrolyte in them. \n\nPotassium hydroxide, also called KOH or “Caustic Potash”, can be bought in small quantities from soap making \nsupply outlets.  One suitable outlet is Summer Bee Meadow at www.meadow.com in their “Soapmaking Supplies” \nsection.  Another provider who supplies small quantities at reasonable cost is \nhttps://www.saltcitysoapworks.com/newshop/product_info.php?cPath=25&products_id=106&osCsid=07d7dba060\n277e6c8a157be165490541   Sodium hydroxide (NaOH - Lowes store: Roebic ‘Heavy Duty’ Crystal Drain Opener) \nis also a good catalyst and it is always used for plate cleansing while KOH is 20% more efficient as the working \nelectrolyte, so cleanse the plates with NaOH and use KOH, which is 20% more electrically efficient, when \noperating the electrolyser. \n\nWhile both Potassium Hydroxide (KOH) and Sodium Hydroxide (NaOH) are excellent materials, they both need to \nbe treated with care.  In the following section, the mixing of KOH is described, and the precautions apply equally \nwell when mixing NaOH.  So when preparing a solution of KOH: \n\nAlways store it in a sturdy air-tight container which is clearly labelled \"DANGER! - Potassium Hydroxide\".   Keep \nthe container in a safe place, where it can’t be reached by children, pets or people who won't take any notice of \nthe label.  If your supply of KOH is delivered in a strong plastic bag, then once you open the bag, you should \ntransfer all its contents to sturdy, air-tight, plastic storage containers, which you can open and close without \nrisking spilling the contents.  Hardware stores sell large plastic buckets with air tight lids that can be used for this \npurpose. \n\nWhen working with dry KOH flakes or granules, wear safety goggles, rubber gloves, a long sleeved shirt, socks \nand long trousers. Also, don’t wear your favourite clothes when handling KOH solution as it is not the best thing to \nget on clothes.  It is also good practice to wear a face mask which covers your mouth and nose.  If you are mixing \nsolid KOH with water, always add the KOH to the water, and not the other way round, and use a plastic container \nfor the mixing, preferably one which has double the capacity of the finished mixture.  The mixing should be done \nin a well-ventilated area which is not draughty as air currents can blow the dry KOH around. \n\nWhen mixing the electrolyte, never use warm water.  The water should be cool because the chemical reaction \nbetween the water and the KOH generates a good deal of heat.  If possible, place the mixing container in a larger \ncontainer filled with cold water, as that will help to keep the temperature down, and if your mixture should “boil","notes":[],"attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","human_url":"https://yogababe.online/reading/BATCH2-006/513","reading_context":{"source_metadata":{"id":"BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly","category":"science","source_sha256":"fed8c4e9335b4315832f75096e6a6d89b7052d51ed7bc7e456985917054dc4bd","source_pages":1875,"published_sections":1965,"published_words":742091,"published_source_pages":1842,"withheld_pages":[{"page":221,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":278,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":384,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":478,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":629,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":697,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":732,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":738,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":821,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":825,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":828,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":831,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":832,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":833,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":837,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":841,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":842,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":843,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1512,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1594,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1598,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1673,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1711,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1736,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1740,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1741,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1743,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1744,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1745,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1747,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1765,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1773,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1778,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"}],"redaction_log":[{"page":50,"changes":[{"kind":"email","count":1}]},{"page":97,"changes":[{"kind":"email","count":1}]},{"page":121,"changes":[{"kind":"email","count":1}]},{"page":143,"changes":[{"kind":"email","count":1}]},{"page":192,"changes":[{"kind":"email","count":1}]},{"page":217,"changes":[{"kind":"email","count":1}]},{"page":226,"changes":[{"kind":"email","count":1}]},{"page":349,"changes":[{"kind":"email","count":1}]},{"page":400,"changes":[{"kind":"email","count":1}]},{"page":436,"changes":[{"kind":"email","count":1}]},{"page":532,"changes":[{"kind":"street_address","count":1}]},{"page":573,"changes":[{"kind":"email","count":1}]},{"page":635,"changes":[{"kind":"email","count":1}]},{"page":698,"changes":[{"kind":"email","count":1}]},{"page":740,"changes":[{"kind":"email","count":1}]},{"page":762,"changes":[{"kind":"email","count":8},{"kind":"phone","count":13}]},{"page":772,"changes":[{"kind":"phone","count":1}]},{"page":776,"changes":[{"kind":"phone","count":1}]},{"page":786,"changes":[{"kind":"phone","count":3}]},{"page":788,"changes":[{"kind":"phone","count":2}]}],"status":"attributed reading edition with marked omissions","hold_reason":null,"source_attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","editorial_note":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. Full publishable extracted text is retained in source order; extraction may lose layout. Page-level omissions are listed.","claims_notice":"No clinical efficacy, guilt, covert coordination or sovereign recognition is established by inclusion.","date_published":"2026-11-28","text_method":"PDF text extraction","references":[],"isbn_status":null,"layout_url":"/pdf/BATCH2-006","viewer_url":"/pdf/BATCH2-006"},"overview":{"synopsis":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","executive_summary":[{"topic":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. "}],"coverage":{"source_pages":1875,"published_sections":1965,"status":"attributed reading edition with marked omissions"},"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation."},"editorial_commentary":{"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.","guides":[{"id":"P-BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. ","url":"/packet/P-BATCH2-006"}],"interpretation":"The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding."},"category_notice_html":"<aside class=\"packet-summary\"><strong>Attributed source text—not an independently verified finding.</strong><p>This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. <a href=\"/articles/reading-evidence\">How to read an allegation</a> · <a href=\"/terms\">Editorial standards and corrections</a></p></aside>","editorial_standards":"/terms","interpretation":"Attributed source text, not an independently verified finding. Preserve allegations, limitations, redaction notes and source attribution.","opsec_context":null}}