{"id":"BATCH2-006-S00514","document_id":"BATCH2-006","ordinal":514,"source_page":499,"title":"10 - 99","words":842,"text":"10 - 99 \nover” it will contain the spillage.  Add only a small amount of KOH at a time, stirring continuously, and if you stop \nstirring for any reason, put the lids back on all containers. \n\nIf, in spite of all precautions, you get some KOH solution on your skin, wash it off with plenty of running cold water \nand apply some vinegar to the skin.  Vinegar is acidic, and will help balance out the alkalinity of the KOH. You can \nuse lemon juice if you don't have vinegar to hand - but it is always recommended to keep a bottle of vinegar \nhandy. \n\nPlate Cleansing:   \nPlate cleansing is always done with NaOH.  Prepare a 5% to 10% (by weight) NaOH solution and let it cool down.  \nA 5% solution ‘by weight’ is 50 grams of NaOH in 950 cc of water.   A 10% solution ‘by weight’ is 100 grams of \nNaOH in 900 cc of water.  As mentioned before, never handle the plates with your bare hands, but always use \nclean rubber gloves.  Put the sanded and rinsed plates into the slots in the electrolyser case, keeping them all the \nsame way round so that they remain magnetically matched.  Fill the electrolyser with the NaOH solution until the \nplates are just covered. \n\nA voltage is now applied across the whole set of plates by attaching the leads to the outermost two plates.  This \nvoltage should be at least 2 volts per cell, but it should not exceed 2.5 volts per cell.  Maintain this voltage across \nthe set of plates for several hours at a time.  The current is likely to be 4 amps or more.  As this process \ncontinues, the boiling action will loosen particles from the pores and surfaces of the metal.  This process produces \nhydroxy gas, so it is very important that the gas is not allowed to collect anywhere indoors (such as on ceilings). \n\nAfter several hours, disconnect the electrical supply and pour the electrolyte solution into a container.   Rinse out \nthe cells thoroughly with distilled water.  Filter the dilute NaOH solution through paper towels or coffee filters to \nremove the particles.   Pour the dilute solution back into the electrolyser and repeat this cleaning process.  You \nmay have to repeat the electrolysis and rinsing process many times before the plates stop putting out particles \ninto the solution.  If you wish, you can use a new NaOH solution each time you cleanse, but you can go through a \nlot of solution just in this cleaning stage if you choose to do it that way.  When cleansing is finished (typically, after \nthree days), do a final rinse with clean distilled water.  It is very important that during cleansing, during \nconditioning and during use, that the polarity of the electrical power is always the same.  In other words, don’t \nswap the battery connections over as that destroys all the preparation work and requires the cleansing and \nconditioning processes to be carried out all over again. \n\nPlate Conditioning: \nUsing the same concentration of solution as in cleansing, fill the electrolyser with dilute solution up to 1/2\" below \nthe tops of the plates.  Do not overfill the cells.  Apply about 2 volts per cell and allow the unit to run.  Remember \nthat very good ventilation is essential during this process.  The cells may overflow, but this is ok for now.  As water \nis consumed, the levels will drop.  Once the cells stabilise with the liquid level at the plate tops or just below, \nmonitor the current draw.   If the current draw is fairly stable, continue with this conditioning phase continuously \nfor two to three days, adding just enough distilled water to replace what is consumed.  If the solution changes \ncolour or develops a layer of crud on the surface of the electrolyte, then the cell stack needs more cleansing \nstages. Do not allow the cells to overfill and overflow at this point.  After two to three days of run time, pour out the \ndilute NaOH solution and rinse out the electrolyser thoroughly with distilled water. \n\nCell Operation: \nMix up a full-strength solution of potassium hydroxide (280 grams of KOH added to 720 cc of water).  The filling of \nthe electrolyser depends on whether straight DC electrolysis is to be used, or resonant electrolysis is to be used.   \n\nFor straight DC electrolysis, fill the electrolyser to about one inch below the tops of the plates.  The DC voltage \napplied to the electrolyser will be about 2 volts per cell or a little less, so this 100-cell electrolyser will have 180 to \n200 volts applied to it.  This voltage will be generated with an inverter. \n\nFor resonant operation, fill the electrolyser to only half the plate height because the hydroxy gas production is so \nrapid that room has to be left for the gas leaving the plates.  With resonant operation, about 1.5 volts per cell is \nused. \n\nTroubleshooting:  \n1. Abnormally low current is caused by improper plate preparation or severe contamination.  Take the plates out \nof the electrolyser and start over again from plate preparation.","notes":[],"attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","human_url":"https://yogababe.online/reading/BATCH2-006/514","reading_context":{"source_metadata":{"id":"BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly","category":"science","source_sha256":"fed8c4e9335b4315832f75096e6a6d89b7052d51ed7bc7e456985917054dc4bd","source_pages":1875,"published_sections":1965,"published_words":742091,"published_source_pages":1842,"withheld_pages":[{"page":221,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":278,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":384,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":478,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":629,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":697,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":732,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":738,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":821,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":825,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":828,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":831,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":832,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":833,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":837,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":841,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":842,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":843,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1512,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1594,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1598,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1673,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1711,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1736,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1740,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1741,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1743,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1744,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1745,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1747,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1765,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1773,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1778,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"}],"redaction_log":[{"page":50,"changes":[{"kind":"email","count":1}]},{"page":97,"changes":[{"kind":"email","count":1}]},{"page":121,"changes":[{"kind":"email","count":1}]},{"page":143,"changes":[{"kind":"email","count":1}]},{"page":192,"changes":[{"kind":"email","count":1}]},{"page":217,"changes":[{"kind":"email","count":1}]},{"page":226,"changes":[{"kind":"email","count":1}]},{"page":349,"changes":[{"kind":"email","count":1}]},{"page":400,"changes":[{"kind":"email","count":1}]},{"page":436,"changes":[{"kind":"email","count":1}]},{"page":532,"changes":[{"kind":"street_address","count":1}]},{"page":573,"changes":[{"kind":"email","count":1}]},{"page":635,"changes":[{"kind":"email","count":1}]},{"page":698,"changes":[{"kind":"email","count":1}]},{"page":740,"changes":[{"kind":"email","count":1}]},{"page":762,"changes":[{"kind":"email","count":8},{"kind":"phone","count":13}]},{"page":772,"changes":[{"kind":"phone","count":1}]},{"page":776,"changes":[{"kind":"phone","count":1}]},{"page":786,"changes":[{"kind":"phone","count":3}]},{"page":788,"changes":[{"kind":"phone","count":2}]}],"status":"attributed reading edition with marked omissions","hold_reason":null,"source_attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","editorial_note":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. Full publishable extracted text is retained in source order; extraction may lose layout. Page-level omissions are listed.","claims_notice":"No clinical efficacy, guilt, covert coordination or sovereign recognition is established by inclusion.","date_published":"2026-11-28","text_method":"PDF text extraction","references":[],"isbn_status":null,"layout_url":"/pdf/BATCH2-006","viewer_url":"/pdf/BATCH2-006"},"overview":{"synopsis":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","executive_summary":[{"topic":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. "}],"coverage":{"source_pages":1875,"published_sections":1965,"status":"attributed reading edition with marked omissions"},"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation."},"editorial_commentary":{"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.","guides":[{"id":"P-BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. ","url":"/packet/P-BATCH2-006"}],"interpretation":"The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding."},"category_notice_html":"<aside class=\"packet-summary\"><strong>Attributed source text—not an independently verified finding.</strong><p>This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. <a href=\"/articles/reading-evidence\">How to read an allegation</a> · <a href=\"/terms\">Editorial standards and corrections</a></p></aside>","editorial_standards":"/terms","interpretation":"Attributed source text, not an independently verified finding. Preserve allegations, limitations, redaction notes and source attribution.","opsec_context":null}}