{"id":"BATCH2-006-S00516","document_id":"BATCH2-006","ordinal":516,"source_page":501,"title":"10 - 101","words":656,"text":"10 - 101 \nWhen he tried separate flooded cells connected in series, he was not able to get anything more than a marginal \nrise in performance over a broader range.  He felt that this was due to each cell in the set having a slightly \ndifferent resonant point which did not match very well with the other cells.  Bob had to go to the series plate \ndesign with accurate spacing and tight tolerance on slots and plates in order to get the resonant responses to line \nup on all cells.  Also, he found that some choices of electrolyte would not produce resonance at any frequency, \nthough he is not sure why.  Some worked well while others worked marginally, so Bob stuck with what worked the \nbest for him - sodium hydroxide (NaOH) and potassium hydroxide (KOH).  Potassium hydroxide is 20% more \nelectrically efficient during electrolysis than sodium hydroxide is. \n\nIt needs to be stressed here, that every electrolyser build is slightly different from all others, even though they may \nhave been meant to be exactly the same.  There will be small differences between the plates in one electrolyser \nand the plates in other electrolysers.  The electrolyte concentration will be slightly different, the plate preparation \nwill be slightly different and the overall magnetic characteristics will be unique to each actual build.  For that \nreason, the tuning of the completed electronics board and the construction of the best possible transformer to \nmatch the electronics to the electrolyser, is always different for each electrolyser built. \n\nThe first step is to build the electronics control board.  The methods for doing this are shown clearly in Bob’s \ndocument entitled “Boyce Electrolyser Project.pdf” which is in the “Files” section of the WorkingWatercar Yahoo \nforum.  Bob has designed a printed circuit board to simplify the construction of the electronic drive circuitry.  To \nsee Bob’s design and to order one of these boards, you need to download and install the free “ExpressPCB” \nsoftware which is located at http://www.expresspcb.com/ExpressPCBHtm/Download.htm and which can display \nhis design files.  The download is just over nine megabytes in size and contains two programs: “ExpressPCB” and \n“ExpressSCH”.  Only the ExpressPCB program needs to be installed for you to be able to place an order for a \nboard. \n\nThe design files needed for you to be able to order the printed circuit board, are located in the “Bob Boyce \nProject” folder in the “Files” section of the WorkingWatercar forum.  If you are not already a member of this Yahoo \nGroup, then you need to join at http://tech.groups.yahoo.com/group/WorkingWatercar/ which is a good idea \nanyway as the forum members are always willing to give helpful advice.  The “Bob Boyce Project” folder contains \nthe “Boyce Electrolyser Project.pdf” document describing the construction of the electronics. \n\nYou need to use the ExpressPCB program to access the “PWM3G.pcb” file which is in the “Bob Boyce Project” \nfolder, as this small 50 Kb file contains the design and construction information needed by the manufacturer to \nconstruct the board for you.  Download the PWM3G.pcb file on to your computer and double-click on it to open it \nwith your newly installed ExpressPCB program.  When the file has loaded, click on the “Layout” option at the top \nof the screen and then click on Click the \"Compute Board Cost\", enter your location, select the Two-layer Board \noption, then pick “MiniBoard”.  Alternatively, you can get the board from The Hydrogen Garage for just US $20 at: \nhttp://stores.homestead.com/hydrogengarage/Categories.bok?category=ELECTRICAL+%2F+CIRCUITS  \nalong with other useful items like an ammeter for checking the current flow through the electrolyser. \n\nWhen your new printed circuit board is delivered, you will need the components to be mounted on it.  Terry has \nset up a pre-filled order form for Digikey which you can use without having to key all the information yourself.  Just \nclick on this link: http://sales.digikey.com/scripts/ru.dll?action=pb_view&pb_glue=1017900 to order the 3G board \nparts which will cost about US $60 for US mainland shipping. \n\nThe completed 3G board looks like this:","notes":[],"attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","human_url":"https://yogababe.online/reading/BATCH2-006/516","reading_context":{"source_metadata":{"id":"BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly","category":"science","source_sha256":"fed8c4e9335b4315832f75096e6a6d89b7052d51ed7bc7e456985917054dc4bd","source_pages":1875,"published_sections":1965,"published_words":742091,"published_source_pages":1842,"withheld_pages":[{"page":221,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":278,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":384,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":478,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":629,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":697,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":732,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":738,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":821,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":825,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":828,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":831,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":832,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":833,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":837,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":841,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":842,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":843,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1512,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1594,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1598,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1673,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1711,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1736,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1740,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1741,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1743,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1744,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1745,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1747,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1765,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1773,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1778,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"}],"redaction_log":[{"page":50,"changes":[{"kind":"email","count":1}]},{"page":97,"changes":[{"kind":"email","count":1}]},{"page":121,"changes":[{"kind":"email","count":1}]},{"page":143,"changes":[{"kind":"email","count":1}]},{"page":192,"changes":[{"kind":"email","count":1}]},{"page":217,"changes":[{"kind":"email","count":1}]},{"page":226,"changes":[{"kind":"email","count":1}]},{"page":349,"changes":[{"kind":"email","count":1}]},{"page":400,"changes":[{"kind":"email","count":1}]},{"page":436,"changes":[{"kind":"email","count":1}]},{"page":532,"changes":[{"kind":"street_address","count":1}]},{"page":573,"changes":[{"kind":"email","count":1}]},{"page":635,"changes":[{"kind":"email","count":1}]},{"page":698,"changes":[{"kind":"email","count":1}]},{"page":740,"changes":[{"kind":"email","count":1}]},{"page":762,"changes":[{"kind":"email","count":8},{"kind":"phone","count":13}]},{"page":772,"changes":[{"kind":"phone","count":1}]},{"page":776,"changes":[{"kind":"phone","count":1}]},{"page":786,"changes":[{"kind":"phone","count":3}]},{"page":788,"changes":[{"kind":"phone","count":2}]}],"status":"attributed reading edition with marked omissions","hold_reason":null,"source_attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","editorial_note":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. Full publishable extracted text is retained in source order; extraction may lose layout. Page-level omissions are listed.","claims_notice":"No clinical efficacy, guilt, covert coordination or sovereign recognition is established by inclusion.","date_published":"2026-11-28","text_method":"PDF text extraction","references":[],"isbn_status":null,"layout_url":"/pdf/BATCH2-006","viewer_url":"/pdf/BATCH2-006"},"overview":{"synopsis":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","executive_summary":[{"topic":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. "}],"coverage":{"source_pages":1875,"published_sections":1965,"status":"attributed reading edition with marked omissions"},"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation."},"editorial_commentary":{"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.","guides":[{"id":"P-BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. ","url":"/packet/P-BATCH2-006"}],"interpretation":"The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding."},"category_notice_html":"<aside class=\"packet-summary\"><strong>Attributed source text—not an independently verified finding.</strong><p>This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. <a href=\"/articles/reading-evidence\">How to read an allegation</a> · <a href=\"/terms\">Editorial standards and corrections</a></p></aside>","editorial_standards":"/terms","interpretation":"Attributed source text, not an independently verified finding. Preserve allegations, limitations, redaction notes and source attribution.","opsec_context":null}}