{"id":"BATCH2-006-S00526","document_id":"BATCH2-006","ordinal":526,"source_page":511,"title":"10 - 111","words":895,"text":"10 - 111 \nPlease note that every winding starts by passing over the toroid, proceeds in a counter-clockwise direction, and \nfinishes by passing under the toroid.  Every winding is created in this way and the quality of workmanship is very \nimportant indeed when making these windings.  Each winding needs to be tight and positioned exactly with turns \ntouching each other in the centre of the toroid and positioned on the outer edge with exactly equal spaces \nbetween each turn.  Your construction work has to be better than that of a commercial supplier and needs to \nreach the quality demanded by the military, which would cost thousands of dollars for each toroid if it were to be \nmade up for you by professionals. \n\nThe three primaries need to be wound on top of the tape wrapping which covers the secondary winding.  These \nthree windings are spaced out equally around the toroid, that is, at 120 degree centres.  The leads of the \nsecondary winding exit through the gap between two of the primary windings.  The primary windings are held in \nplace with beeswax, and then tightly taped.  The primaries may need more than a single layer, and they are \nwound with the same direction of winds as the secondary, and the same care for even winding spacing as the \nsecondary needed.  Tape the entire core well with tightly-stretched PVC electrical tape after winding, to ensure \nthat the primary windings do not move and then add an outer layer of winding tape.  Bob uses the 1P802YE type \non 3\" rolls, both the 1\" and 2\" widths from: \nhttp://www.lodestonepacific.com/distrib/pdfs/tape/1p802.pdf \n\nThis is where the generic information ends.  The exact details of the primary windings must be determined from \nthe operational characteristics of the cells.  This means that you must build, cleanse and condition your cells prior \nto making the operational measurements.  This is done as follows:  After full plate cleansing as described earlier, \ncondition the plates until the cell stack reaches at least 150% but ideally 200% or more of Faraday’s maximum \npower efficiency (2.34 Watt-Hours per Litre per Hour).  Then, allow the cell stack to cool to room temperature.  \nThe cell stack is then powered up with a variable-voltage power supply and the voltage adjusted until the cell \ncurrent is exactly 2 amps.  Write down the voltage needed to give this 2 amp current flow, and do it promptly \nbefore the cell starts to warm up again. \n\nThe objective here is to have the complex waveform generated by the electronics, produce voltages of about 25% \nof this measured voltage, so divide your measured voltage by four.  The output from the electronics board is about \n12.5 volts, so divide again by 12.5 to get the turns-ratio for the toroidal transformer.  This is normally in the range \nof 3.0 to 3.5 and that means that the secondary winding needs to have that times as many turns in it as each \nprimary winding does.  \n\nFor example, (and example only) say your measured voltage happens to be 155 volts.  Then the turns ratio would \nbe 155 divided by 4 which is 38.75, and then divide that by 12.5 which gives 3.1 which is the turns ratio.  If your \nsecondary winding has, say, 134 turns in it, then the number of turns in each of the three primary windings would \nbe 134 / 3.1 which is 43.23 turns.  Round this upwards to give 44 turns. \n\nIf the number of turns which you use is off by one turn, then the tuning of the electronics board can compensate \nfor it.  If the number of primary turns is off by two turns, then it is possible that you might just be able to \ncompensate for the error by tuning the board, but it is unlikely that you will.  If the number of turns is three or more \naway from the optimum number calculated, then the impedance of the primary windings will be too far out for the \nboard to tune it. \n\nNormally, the diameter of the wire used in the primaries will be greater than that of the secondary because it will \nbe driven by a much lower voltage and so will need a much higher current, but that is not the case here.  Now that \nyou have cleansed and conditioned the plates in your electrolyser, power up your inverter with your vehicle engine \nrunning at 2000 rpm or so, and measure the DC current taken by the inverter.  This is the level of current which \nthe primary windings have to carry, so the wire size can be selected from this measurement.   Each primary \nwinding is pulsed, so it is not carrying current all of the time, also, the final primary current is the sum of the three \npulsing signals, so a reduction can be allowed for that.  While the wire diameter for the primary windings of each \ntoroidal transformer need to be calculated separately, a common diameter turns out to be AWG #20 (21 SWG).  \nThe wire length for the primaries will be greater per turn as the turns are now being made over the secondary \nwinding.  Forty-eight turns of #20 wire are likely to require at least thirty-five feet and that is for each of the three \nwindings, assuming that all turns can be laid flat side-by-side.  If it is necessary to make each a two-layer winding, \nthen the wire length will increase further. ","notes":[],"attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","human_url":"https://yogababe.online/reading/BATCH2-006/526","reading_context":{"source_metadata":{"id":"BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly","category":"science","source_sha256":"fed8c4e9335b4315832f75096e6a6d89b7052d51ed7bc7e456985917054dc4bd","source_pages":1875,"published_sections":1965,"published_words":742091,"published_source_pages":1842,"withheld_pages":[{"page":221,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":278,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":384,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":478,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":629,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":697,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":732,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":738,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":821,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":825,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":828,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":831,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":832,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":833,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":837,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":841,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":842,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":843,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1512,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1594,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1598,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1673,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1711,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1736,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1740,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1741,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1743,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1744,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1745,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1747,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1765,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1773,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1778,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"}],"redaction_log":[{"page":50,"changes":[{"kind":"email","count":1}]},{"page":97,"changes":[{"kind":"email","count":1}]},{"page":121,"changes":[{"kind":"email","count":1}]},{"page":143,"changes":[{"kind":"email","count":1}]},{"page":192,"changes":[{"kind":"email","count":1}]},{"page":217,"changes":[{"kind":"email","count":1}]},{"page":226,"changes":[{"kind":"email","count":1}]},{"page":349,"changes":[{"kind":"email","count":1}]},{"page":400,"changes":[{"kind":"email","count":1}]},{"page":436,"changes":[{"kind":"email","count":1}]},{"page":532,"changes":[{"kind":"street_address","count":1}]},{"page":573,"changes":[{"kind":"email","count":1}]},{"page":635,"changes":[{"kind":"email","count":1}]},{"page":698,"changes":[{"kind":"email","count":1}]},{"page":740,"changes":[{"kind":"email","count":1}]},{"page":762,"changes":[{"kind":"email","count":8},{"kind":"phone","count":13}]},{"page":772,"changes":[{"kind":"phone","count":1}]},{"page":776,"changes":[{"kind":"phone","count":1}]},{"page":786,"changes":[{"kind":"phone","count":3}]},{"page":788,"changes":[{"kind":"phone","count":2}]}],"status":"attributed reading edition with marked omissions","hold_reason":null,"source_attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","editorial_note":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. Full publishable extracted text is retained in source order; extraction may lose layout. Page-level omissions are listed.","claims_notice":"No clinical efficacy, guilt, covert coordination or sovereign recognition is established by inclusion.","date_published":"2026-11-28","text_method":"PDF text extraction","references":[],"isbn_status":null,"layout_url":"/pdf/BATCH2-006","viewer_url":"/pdf/BATCH2-006"},"overview":{"synopsis":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","executive_summary":[{"topic":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. "}],"coverage":{"source_pages":1875,"published_sections":1965,"status":"attributed reading edition with marked omissions"},"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation."},"editorial_commentary":{"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.","guides":[{"id":"P-BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. ","url":"/packet/P-BATCH2-006"}],"interpretation":"The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding."},"category_notice_html":"<aside class=\"packet-summary\"><strong>Attributed source text—not an independently verified finding.</strong><p>This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. <a href=\"/articles/reading-evidence\">How to read an allegation</a> · <a href=\"/terms\">Editorial standards and corrections</a></p></aside>","editorial_standards":"/terms","interpretation":"Attributed source text, not an independently verified finding. Preserve allegations, limitations, redaction notes and source attribution.","opsec_context":null}}