{"id":"BATCH2-006-S00757","document_id":"BATCH2-006","ordinal":757,"source_page":736,"title":"13 - 38","words":587,"text":"13 - 38 \nImportant Note \nGary of G. L. Chemelec commenting on “The HydroStar” circuit which sounds to be based on the same style \nof circuitry, states that the circuit and design are riddled with serious errors, some of which are:  \n 1. The use of the 741 WILL NOT WORK! Pin 5 is a Voltage Control pin that already has its own voltage of \n2/3 of the Supply voltage so it requires a pull down resistor, not an IC to control it.  \n 2. The 2K Pulse width adjust will blow the 555 timer if adjusted all the way down. It needs an additional \nresistor to limit current to those pins on the IC.  \n 3. The output of the 555, Pin 3 is fed to the CD4059 as well as a TC4420CPA (Mosfet Driver). This driver is \na waste of money as it is not needed.  \n 4. The Output of the TC4420CPA is then fed to the IRF510 Mosfet which is now obsolete, however you can \nuse an RFP50N06 (50V, 60A).  \n 5. There is no schematic of the CD4059. They should have shown pin 1 as in, pin 23 as out, pins 3, 10, 13, \n14, and 24 connected to 12 volts and pins 2, 4, 5, 6, 7, 8, 9, 11, 12, 15, 16, 17, 18, 19, 20, 21, and 22 \nconnected to ground.   \n 6. The \"Strength Adjust\" Only Needs the variable resistor connected to Pin 5 and the Ground. The \nConnection of this control to the Supply Voltage Make Absolutely No Difference in the Output \nWaveforms, as the IC only needs a 2/3's voltage on this Pin and this is supplied internally, Within the IC.  \n 7. The \"Frequency Adjust\", Connects to Pins 6 & 7 of This 555.  Supply to the battery Will Destroy the 555. \nso another resistor is needed to prevent this from happening.  \n\nThis is just a small list of what is wrong. There is MUCH MORE and even after the thing is built it does NOT \nWORK! If you want to experiment then please do, but I would suggest you just make your own Pulse Width \nModulator.  \n\nThere are also many problems with the design of the reaction chamber and simply put, even if you did get it \nto work you would need more of these units than you could ever fit in your car to even think about running \nthe engine. Simply put, the unit will NOT create enough gas to run much of anything.  Don't get me wrong, I \ndo think that the idea is GREAT and that it can be done.  \n\nReaction chamber:   \nThe suggested reaction chamber arrangement is:  \n\nIt is suggested that you use a section of 4\" PVC waste pipe with a threaded screw-cap fitting on one end and \na standard end-cap at the other. Make sure to drill-and-epoxy or tap threads through the PVC components \nfor all fittings. Set and control the water level in the chamber so that the pipe electrodes are well covered and \nthere is still ample headroom left to build up the hydrogen/oxygen gas pressure. Use stainless steel wires \ninside the chamber or otherwise use a protective coating; use insulated wires outside. Ensure that the epoxy \nseals are perfect or alternatively, lay down a bead of water-proof silicone sufficient to hold the pressure.  \n\nThe screw fitting may require soft silicone sealant, or a gasket.  Its purpose is to maintain the pressure in the \ncylinder and yet allow periodic inspection of the electrodes. Make sure that there are no leaks and you will","notes":[],"attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","human_url":"https://yogababe.online/reading/BATCH2-006/757","reading_context":{"source_metadata":{"id":"BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly","category":"science","source_sha256":"fed8c4e9335b4315832f75096e6a6d89b7052d51ed7bc7e456985917054dc4bd","source_pages":1875,"published_sections":1965,"published_words":742091,"published_source_pages":1842,"withheld_pages":[{"page":221,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":278,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":384,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":478,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":629,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":697,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":732,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":738,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":821,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":825,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":828,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":831,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":832,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":833,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":837,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":841,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":842,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":843,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1512,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1594,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1598,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1673,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1711,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1736,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1740,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1741,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1743,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1744,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1745,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1747,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1765,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1773,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1778,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"}],"redaction_log":[{"page":50,"changes":[{"kind":"email","count":1}]},{"page":97,"changes":[{"kind":"email","count":1}]},{"page":121,"changes":[{"kind":"email","count":1}]},{"page":143,"changes":[{"kind":"email","count":1}]},{"page":192,"changes":[{"kind":"email","count":1}]},{"page":217,"changes":[{"kind":"email","count":1}]},{"page":226,"changes":[{"kind":"email","count":1}]},{"page":349,"changes":[{"kind":"email","count":1}]},{"page":400,"changes":[{"kind":"email","count":1}]},{"page":436,"changes":[{"kind":"email","count":1}]},{"page":532,"changes":[{"kind":"street_address","count":1}]},{"page":573,"changes":[{"kind":"email","count":1}]},{"page":635,"changes":[{"kind":"email","count":1}]},{"page":698,"changes":[{"kind":"email","count":1}]},{"page":740,"changes":[{"kind":"email","count":1}]},{"page":762,"changes":[{"kind":"email","count":8},{"kind":"phone","count":13}]},{"page":772,"changes":[{"kind":"phone","count":1}]},{"page":776,"changes":[{"kind":"phone","count":1}]},{"page":786,"changes":[{"kind":"phone","count":3}]},{"page":788,"changes":[{"kind":"phone","count":2}]}],"status":"attributed reading edition with marked omissions","hold_reason":null,"source_attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","editorial_note":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. Full publishable extracted text is retained in source order; extraction may lose layout. Page-level omissions are listed.","claims_notice":"No clinical efficacy, guilt, covert coordination or sovereign recognition is established by inclusion.","date_published":"2026-11-28","text_method":"PDF text extraction","references":[],"isbn_status":null,"layout_url":"/pdf/BATCH2-006","viewer_url":"/pdf/BATCH2-006"},"overview":{"synopsis":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","executive_summary":[{"topic":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. "}],"coverage":{"source_pages":1875,"published_sections":1965,"status":"attributed reading edition with marked omissions"},"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation."},"editorial_commentary":{"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.","guides":[{"id":"P-BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. ","url":"/packet/P-BATCH2-006"}],"interpretation":"The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding."},"category_notice_html":"<aside class=\"packet-summary\"><strong>Attributed source text—not an independently verified finding.</strong><p>This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. <a href=\"/articles/reading-evidence\">How to read an allegation</a> · <a href=\"/terms\">Editorial standards and corrections</a></p></aside>","editorial_standards":"/terms","interpretation":"Attributed source text, not an independently verified finding. Preserve allegations, limitations, redaction notes and source attribution.","opsec_context":null}}