{"id":"BATCH2-006-S00804","document_id":"BATCH2-006","ordinal":804,"source_page":784,"title":"14 - 44","words":661,"text":"14 - 44 \nHow can one readily determine if the water from a well, pump, stream, etc. is safe to drink?  The common\nprocedure is to test the water for bacterial indicators of faecal pollution.  There are two groups of \nindicators which are used.  The first is the coliform bacteria which are used as indicators in developed\ncountries where water is chlorinated.  Coliform bacteria may come from faeces or from plants.  Among\nthe coliform bacteria is the second indicator, Escherichia coli.  This bacterium is present in large numbers\nin human faeces (approximately 100,000,000 per gram of faeces) and that of other mammals.  This is the\nmain indicator used if water is not chlorinated.   A water source containing 100 E. coli per 100 ccs poses \na substantial risk of disease. \n\nThe standard method of testing water for the presence of coliforms and E. coli requires trained personnel\nand a good laboratory facility or field unit which are usually not present in developing countries. Thus, \nwater supplies are almost never tested. \n\nA new approach to testing in developing countries  \nIn 1987, the Colilert MPM Test (CLT) was introduced as the first method which used a defined substrate\ntechnology to simultaneously detect coliforms and E. coli.   The CLT comes as dry chemicals in test tubes\ncontaining two indicator nutrients: one for coliforms and one for E. coli.   The CLT involves adding 10 ml\nof water to a tube, shaking to dissolve the chemicals, and incubating at body temperature for 24 hours.  I \nprefer incubating tubes under my belt against my body.   At night I sleep on my back and use night\nclothes to hold the tubes against my body. \n\nIf no coliform bacteria are present, the water will remain clear.  However, if one or more coliforms are \npresent in the water, after 24 hours their growth will metabolise ONPG and the water will change in colour\nfrom clear to yellow (resembling urine).   If E. coli is among the coliform bacteria present, it will metabolise\nMUG and the tube will fluoresce blue when a battery-operated, long-wave ultraviolet light shines on it, \nindicating a serious health hazard.   I have invited participants at solar box cooker workshops in Sierra\nLeone, Mali, Mauritania, and Nepal to test their home water supplies with CLT.  One hundred and twenty \nparticipants brought in samples.   In all four countries, whether the water was from urban or rural areas,\nthe majority of samples contained coliforms, and at least half of these had E. coli present.  Bacteriological\ntesting of the ONPG and MUG positive tubes brought back from Mali and Mauritania verified the\npresence of coliforms/E. coli in approximately 95% of the samples.  It is likely that soon the Colilert MPN\ntest will be modified so that the test for E. coli will not require an ultraviolet light, and the tube will turn a \ndifferent colour than yellow if E coli is present.  This will make the test less expensive and easier to widely\nuse in developing countries to assess water sources.  \n\nEffect of safe water on diarrhoea in children \nWhat would be the effect if contaminated water could be made safe for drinking by pasteurisation or\nboiling?   One estimate predicts that if in the Philippines, families at present using moderately\ncontaminated wells (100 E. coli per 100 ml) were able to use a high-quality water source, diarrhoea \namong their children would be reduced by over 30%.  Thus, if water which caused a MUG (+) test were\nsolar pasteurised so it would be clear, this would help reduce the chance of diarrhoea, especially in\nchildren. \n\nWater pasteurisation indicator \n\nHow can one determine if heated water has reached 65O C?   In 1988, Dr. Fred Barrett (USDA, retired) \ndeveloped the prototype for the Water Pasteurisation Indicator (WAPI).   In 1992, Dale Andreatta, a\ngraduate engineering student at the University of California, Berkeley, developed the current WAPI.  The\nWAPI is a polycarbonate tube, sealed at both ends, partially filled with a soybean fat which melts at 69O C","notes":[],"attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","human_url":"https://yogababe.online/reading/BATCH2-006/804","reading_context":{"source_metadata":{"id":"BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly","category":"science","source_sha256":"fed8c4e9335b4315832f75096e6a6d89b7052d51ed7bc7e456985917054dc4bd","source_pages":1875,"published_sections":1965,"published_words":742091,"published_source_pages":1842,"withheld_pages":[{"page":221,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":278,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":384,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":478,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":629,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":697,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":732,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":738,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":821,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":825,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":828,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":831,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":832,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":833,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":837,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":841,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":842,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":843,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1512,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1594,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1598,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1673,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1711,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1736,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1740,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1741,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1743,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1744,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1745,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1747,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1765,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1773,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1778,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"}],"redaction_log":[{"page":50,"changes":[{"kind":"email","count":1}]},{"page":97,"changes":[{"kind":"email","count":1}]},{"page":121,"changes":[{"kind":"email","count":1}]},{"page":143,"changes":[{"kind":"email","count":1}]},{"page":192,"changes":[{"kind":"email","count":1}]},{"page":217,"changes":[{"kind":"email","count":1}]},{"page":226,"changes":[{"kind":"email","count":1}]},{"page":349,"changes":[{"kind":"email","count":1}]},{"page":400,"changes":[{"kind":"email","count":1}]},{"page":436,"changes":[{"kind":"email","count":1}]},{"page":532,"changes":[{"kind":"street_address","count":1}]},{"page":573,"changes":[{"kind":"email","count":1}]},{"page":635,"changes":[{"kind":"email","count":1}]},{"page":698,"changes":[{"kind":"email","count":1}]},{"page":740,"changes":[{"kind":"email","count":1}]},{"page":762,"changes":[{"kind":"email","count":8},{"kind":"phone","count":13}]},{"page":772,"changes":[{"kind":"phone","count":1}]},{"page":776,"changes":[{"kind":"phone","count":1}]},{"page":786,"changes":[{"kind":"phone","count":3}]},{"page":788,"changes":[{"kind":"phone","count":2}]}],"status":"attributed reading edition with marked omissions","hold_reason":null,"source_attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","editorial_note":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. Full publishable extracted text is retained in source order; extraction may lose layout. Page-level omissions are listed.","claims_notice":"No clinical efficacy, guilt, covert coordination or sovereign recognition is established by inclusion.","date_published":"2026-11-28","text_method":"PDF text extraction","references":[],"isbn_status":null,"layout_url":"/pdf/BATCH2-006","viewer_url":"/pdf/BATCH2-006"},"overview":{"synopsis":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","executive_summary":[{"topic":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. "}],"coverage":{"source_pages":1875,"published_sections":1965,"status":"attributed reading edition with marked omissions"},"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation."},"editorial_commentary":{"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.","guides":[{"id":"P-BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. ","url":"/packet/P-BATCH2-006"}],"interpretation":"The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding."},"category_notice_html":"<aside class=\"packet-summary\"><strong>Attributed source text—not an independently verified finding.</strong><p>This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. <a href=\"/articles/reading-evidence\">How to read an allegation</a> · <a href=\"/terms\">Editorial standards and corrections</a></p></aside>","editorial_standards":"/terms","interpretation":"Attributed source text, not an independently verified finding. Preserve allegations, limitations, redaction notes and source attribution.","opsec_context":null}}