{"id":"BATCH2-006-S01501","document_id":"BATCH2-006","ordinal":1501,"source_page":1432,"title":"A - 586","words":698,"text":"A - 586 \n\nFinally, an example of the correlation between the drive pack PAGD load voltage and the charge pack PAGD \ncharging voltage, as a function of the duration of the intervening PAGD run between resistive discharge \nmeasurements, is shown in Fig.21, for the PAGD run corresponding to group 4 of Table 8. \n\nUsing the same pulse generator with H200 Al 128 cm2 plates, in a double diode configuration, and the same \ncircuit values (but with CP = 23 cells), three experiments were conducted at different PAGD frequencies, as a \nfunction of varying air pressure.   Analysis of driver pack losses and charge pack gains by the extensive load \ndischarge measurement method, as described before, led to the determination of the gross and net gains \n(respectively, without and with losses included) per pulse, in milliwatt-hour, for each frequency, as well as of the \ngross and net power gains per second of PAGD operation. The results are shown in Table 9.  Even though the \ngross and net gains of power per pulse were observed to increase with decreasing frequency, the gross power \ngain per unit time increased with increasing frequency.  However, this last trend does not necessarily translate \ninto a higher net gain per unit time, because the losses in the driver pack (not shown) also increase significantly \nwith PAGD frequency.   These losses are in all probability related to more energy retention by the plasma at \nhigher frequencies when plasma extinction becomes incomplete.   We expect net gains to reach optimal \nthresholds for any given type of circuit configuration set of values and pulse generator dimensions. \n\nCertain additional observations made during experiments with the double diode configuration of Fig.10A may \nassist in understanding of the invention. \n\n1) Replacing residual air with argon gas leads to higher PAGD frequencies, as noted by us when utilising a 128 \ncm2 H200 AC plate pulse generator in the double diode configuration (V = 575).   At 1 Torr, the pulsation rate \nwent from 20 PPS in air to 1300-1400 PPS in argon.   With 29 12V cells in the charge pack, input currents ceased \nto flow into it.   Under these conditions, the tube potential across the plates decreased and the drop across the \ninput resistor increased.   The value of E (= V/d) became smaller (gap size = 3 cm from plate to axial anode \ncollector), as the extinction voltage decreased. \n\n2) With frequencies of 400 PPS, the currents flowing into the charge pack fell to zero.  Replacing a fast-recovery \ntype HFR 120 (1200v, 40A) diode bridge by a type MUR 860 (600v, 8A) diode bridge had no effect. When the \namplitude of plate potential oscillations falls below the potential of the charge pack, there is also a tendency to \nproduce arc discharges.  For output currents from the vacuum pulse generator to enter the charge pack, the \nnumber of cells must be reduced so that the potential of the charge pack is low enough to admit the transduced \ncurrents.   A reduction from 29 to 23 cells allowed currents of 250 mA to enter the CP, and further reduction to 19 \ncells doubled these currents (per polarity arm). \n\n3) Our observations show that it suffices under these conditions (CP of 19 cells) to increase the vacuum, so that \nthe frequency decreases, and the plate potential and the charge pack input currents increase.  At 0.1 Torr, the \ncurrents reached 1A DC per plate, and at 0.05 Torr, 2A DC \n\nThe interconnection between these factors indicates that the extinction voltage is a function of the PAGD \nfrequency: the higher the PAGD frequency, the lower the extinction voltage, until empirical (in distinction from \npredicted) VAD field values are reached.   As a consequence, the start voltage of the charge pack must be \nadjusted, by varying the number of cells composing it, so that it lies below the lowest extinction voltage of the \nPAGD, for any given geometry and gap distance. \n\nSecondly, as the ion plasma is made more rarefied, the frequency of the emissions decreases, but the peak \nvalues of the output voltage and current per pulse increase.   The slower the PAGD and the more rarefied the \natmosphere, the higher is the output energy produced by the system relative to the input energy. ","notes":[],"attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","human_url":"https://yogababe.online/reading/BATCH2-006/1501","reading_context":{"source_metadata":{"id":"BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly","category":"science","source_sha256":"fed8c4e9335b4315832f75096e6a6d89b7052d51ed7bc7e456985917054dc4bd","source_pages":1875,"published_sections":1965,"published_words":742091,"published_source_pages":1842,"withheld_pages":[{"page":221,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":278,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":384,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":478,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":629,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":697,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":732,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":738,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":821,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":825,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":828,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":831,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":832,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":833,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":837,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":841,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":842,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":843,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1512,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1594,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1598,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1673,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1711,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1736,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1740,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1741,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1743,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1744,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1745,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1747,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1765,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1773,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1778,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"}],"redaction_log":[{"page":50,"changes":[{"kind":"email","count":1}]},{"page":97,"changes":[{"kind":"email","count":1}]},{"page":121,"changes":[{"kind":"email","count":1}]},{"page":143,"changes":[{"kind":"email","count":1}]},{"page":192,"changes":[{"kind":"email","count":1}]},{"page":217,"changes":[{"kind":"email","count":1}]},{"page":226,"changes":[{"kind":"email","count":1}]},{"page":349,"changes":[{"kind":"email","count":1}]},{"page":400,"changes":[{"kind":"email","count":1}]},{"page":436,"changes":[{"kind":"email","count":1}]},{"page":532,"changes":[{"kind":"street_address","count":1}]},{"page":573,"changes":[{"kind":"email","count":1}]},{"page":635,"changes":[{"kind":"email","count":1}]},{"page":698,"changes":[{"kind":"email","count":1}]},{"page":740,"changes":[{"kind":"email","count":1}]},{"page":762,"changes":[{"kind":"email","count":8},{"kind":"phone","count":13}]},{"page":772,"changes":[{"kind":"phone","count":1}]},{"page":776,"changes":[{"kind":"phone","count":1}]},{"page":786,"changes":[{"kind":"phone","count":3}]},{"page":788,"changes":[{"kind":"phone","count":2}]}],"status":"attributed reading edition with marked omissions","hold_reason":null,"source_attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","editorial_note":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. Full publishable extracted text is retained in source order; extraction may lose layout. Page-level omissions are listed.","claims_notice":"No clinical efficacy, guilt, covert coordination or sovereign recognition is established by inclusion.","date_published":"2026-11-28","text_method":"PDF text extraction","references":[],"isbn_status":null,"layout_url":"/pdf/BATCH2-006","viewer_url":"/pdf/BATCH2-006"},"overview":{"synopsis":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","executive_summary":[{"topic":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. "}],"coverage":{"source_pages":1875,"published_sections":1965,"status":"attributed reading edition with marked omissions"},"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation."},"editorial_commentary":{"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.","guides":[{"id":"P-BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. ","url":"/packet/P-BATCH2-006"}],"interpretation":"The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding."},"category_notice_html":"<aside class=\"packet-summary\"><strong>Attributed source text—not an independently verified finding.</strong><p>This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. <a href=\"/articles/reading-evidence\">How to read an allegation</a> · <a href=\"/terms\">Editorial standards and corrections</a></p></aside>","editorial_standards":"/terms","interpretation":"Attributed source text, not an independently verified finding. Preserve allegations, limitations, redaction notes and source attribution.","opsec_context":null}}