{"id":"BATCH2-006-S01719","document_id":"BATCH2-006","ordinal":1719,"source_page":1639,"title":"A - 793","words":624,"text":"A - 793 \n\nTABLE 2 - The micro-organism count \n\nTime \n(minutes) \nBacteria count/ml \nMold colony count/ml \n0 \n3,400 \n37,000 \n20 \n1,300 \n17,000 \n40 \n90 \n10 \n\nThe favour and colour of the fruit drink had not changed after the test.  The bacteria sterilisation is 97.5% and that \nof mold colony has been sterilised more than 99%.  This has given proof that the under-liquid plasma has the \nsame capability as those operated in a gaseous environment. \n\nThe time for the treatment could be reduced by providing forced circulation of the liquid and increasing the \nelectrode size.  Sterilisation of drinking water imposes no limit on the temperature.  Higher voltage input for better \nplasma glow discharge spreading over larger and multiple electrodes should be able to remove all harmful \nchemical substance, bacteria, biological matter and microbial matter, thus meeting the municipal requirement for \ndrinking water. \n\nREDUCTION OF METAL OXIDE \nOne trial experiment to reduce TiO2 back to Titanium metal has been attempted with little success.  It was found \nthat in the X-ray diffraction test, minor traces of titanium nitride and titanium monoxide (TiO) were found.  In the \nexperiment, only a minor electrolyte of 0.05% KOH with 25% methanol added to the distilled water was used to \nincrease the production of hydrogen.  The applied voltage was fixed at 1,850 V and the current fluctuated in the \nrange of 200 mA to 500 mA.  Ultrasonic radiation up to 40 KHz was also provided through an ultrasonic bath.  The \ntemperature recorded in the bath liquid rose from 46OC to 75OC at the end of the 60 minute test.  The fine TiO2 \nwith was suspended with ultrasonic radiation, in the bath liquid in colloidal form, showing as a milky white colour, \nwhich gradually became a milky yellow colour towards the end of the experiment.  The bath liquid also became \nviscous. \n\nThe X-ray refractive “d” value of TiO2 were: \n\nBefore the experiment: 3.512, 1.892, 2.376 but after the experiment there were two new groups of “d” \nmeasurements not seen before the experiment: \na:  2.089, 1.480, 2.400 \nb:  2.400, 2.329, 2.213 \nThis indicates a new material, positioned between TiO and n-Ti3N2-x. \n\nThis experiment indicates that a change did happen to the TiO2, possibly because of the limited voltage and \ncurrent available as input, which could not provide the intensity of plasma discharge needed to effect the \nreduction process properly.  Higher concentration of either HCl or H2SO4 should be use as reagent demonstrated \nin the following chemical reaction and in the same time serving as electrolyte.  The horizontal reactor is not a \nsuitable piece of equipment to undertake such experiment; it is adopted merely for convenience.   A wire-in-tube \nand tube-in-tube reactor would be a suitable candidate, which would keep the metal oxide exposed to plasma \ndischarge throughout the whole of the duration of the experiment.  Further, more hydrogen or CO gases produced \nduring the process may be passed back to the reactor to enhance the reaction.  (Methane is a suitable gas for this \ntype of reduction process, as both hydrogen and CO gas will be produced to enhance the reaction).  The following \nare the chemical formula, which suggested by transforming TiO2 to either TiCl4 or TiOSO4 as a soluble ionic \ncompound, will facilitate its reduction with prolong exposure to active atomic hydrogen under the influence of a \nplasma catalytic environment. \n\nTiO2 + 4HCl → TiCl4 + 2H2O,  \nTiCl4 + 4H → Ti + 4HCl. \nTiO2 + H2SO4 → TiO(SO4) + H2O,  \nTiO(SO4) + 4H → Ti + H2SO4 + H2O \nWhere TiCl4 is readily produced by an established process from ilmenite. \n\nSimilarly, aluminium oxide Al2O3 can first be transformed to AlCl3, which is soluble ionic compound, ready to be \nextracted by electro-deposition enhanced with plasma-reduction and plasma-electroplating process: \n\nAl2O3 + 6HCl → 2AlCl3 + 3H2O,","notes":[],"attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","human_url":"https://yogababe.online/reading/BATCH2-006/1719","reading_context":{"source_metadata":{"id":"BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly","category":"science","source_sha256":"fed8c4e9335b4315832f75096e6a6d89b7052d51ed7bc7e456985917054dc4bd","source_pages":1875,"published_sections":1965,"published_words":742091,"published_source_pages":1842,"withheld_pages":[{"page":221,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":278,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":384,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":478,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":629,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":697,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":732,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":738,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":821,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":825,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":828,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":831,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":832,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":833,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":837,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":841,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":842,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":843,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1512,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1594,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1598,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1673,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1711,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1736,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1740,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1741,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1743,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1744,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1745,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1747,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1765,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1773,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"},{"page":1778,"reason":"Potential weapon-specific material requires selective review; not in searchable edition"}],"redaction_log":[{"page":50,"changes":[{"kind":"email","count":1}]},{"page":97,"changes":[{"kind":"email","count":1}]},{"page":121,"changes":[{"kind":"email","count":1}]},{"page":143,"changes":[{"kind":"email","count":1}]},{"page":192,"changes":[{"kind":"email","count":1}]},{"page":217,"changes":[{"kind":"email","count":1}]},{"page":226,"changes":[{"kind":"email","count":1}]},{"page":349,"changes":[{"kind":"email","count":1}]},{"page":400,"changes":[{"kind":"email","count":1}]},{"page":436,"changes":[{"kind":"email","count":1}]},{"page":532,"changes":[{"kind":"street_address","count":1}]},{"page":573,"changes":[{"kind":"email","count":1}]},{"page":635,"changes":[{"kind":"email","count":1}]},{"page":698,"changes":[{"kind":"email","count":1}]},{"page":740,"changes":[{"kind":"email","count":1}]},{"page":762,"changes":[{"kind":"email","count":8},{"kind":"phone","count":13}]},{"page":772,"changes":[{"kind":"phone","count":1}]},{"page":776,"changes":[{"kind":"phone","count":1}]},{"page":786,"changes":[{"kind":"phone","count":3}]},{"page":788,"changes":[{"kind":"phone","count":2}]}],"status":"attributed reading edition with marked omissions","hold_reason":null,"source_attribution":"Supplied archival document; original authorship and rights remain. Source statements are not automatically independently verified findings.","editorial_note":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. Full publishable extracted text is retained in source order; extraction may lose layout. Page-level omissions are listed.","claims_notice":"No clinical efficacy, guilt, covert coordination or sovereign recognition is established by inclusion.","date_published":"2026-11-28","text_method":"PDF text extraction","references":[],"isbn_status":null,"layout_url":"/pdf/BATCH2-006","viewer_url":"/pdf/BATCH2-006"},"overview":{"synopsis":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","executive_summary":[{"topic":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. "}],"coverage":{"source_pages":1875,"published_sections":1965,"status":"attributed reading edition with marked omissions"},"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation."},"editorial_commentary":{"evidence_checks":"Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.","guides":[{"id":"P-BATCH2-006","title":"A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide","summary":"A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.","evidence_and_limits":"An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design. ","url":"/packet/P-BATCH2-006"}],"interpretation":"The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding."},"category_notice_html":"<aside class=\"packet-summary\"><strong>Attributed source text—not an independently verified finding.</strong><p>This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. <a href=\"/articles/reading-evidence\">How to read an allegation</a> · <a href=\"/terms\">Editorial standards and corrections</a></p></aside>","editorial_standards":"/terms","interpretation":"Attributed source text, not an independently verified finding. Preserve allegations, limitations, redaction notes and source attribution.","opsec_context":null}}