---
canonical: "https://yogababe.online/reading/BATCH2-006/1009"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 1009 · A - 135 | Rejuvenati"
content_sha256: "80018d9d18009e0d657be56d84a65b138b0348f170c06f73d79ec095e8b791ba"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 981 · section 1009/1965 · approximately 4 minutes

## A - 135

A - 135  
start of a cycle are shown to correspond to the above description with reference to Fig.18. Accordingly, the coil  
and capacitor combinations 213/216, 214/217 and 215/218 are shown connected with their gap terminals,  
respectively, 223/224, 226/227 and 229/230. On the rotor coil and capacitor connection, three separate discs  
291, 292 and 293 are shown, each with a single gap terminal. The discs 291 - 293 are rotated so as to position  
their respective gap terminals 201a, 201b and 201c, at 120 degree increments, with the 0 degrees position  
corresponding to the 0 degrees position of U-gap terminal 222 on disc 230.

Representative gap terminals are shown about the peripheries of discs 230, 291 - 293 to indicate clearly how, as  
the discs turn in unison, the gap alignments correspond so that three rotor coils always line up with three stator  
coils at 120 degree intervals about the rotary path, producing an alignment every 40 degrees, there being nine  
stator coils. Thus, there are three simultaneous discharges into stator coils and three into rotor coils at each 40  
degree position. Nine positions displaced 40 degrees apart provide a total of 27 discharge points for capacitors  
into the rotor coils and 27 discharge points for capacitors into the stator coils in one revolution of the rotor.

It will be understood that, as illustrated in Fig.17 and Fig.18, nine individual electromagnet coils are shown in the  
stator and three in the rotor, in order to show in its simplest form, how the three rotor electromagnets are stepped  
forward from alignment with three of the stator electromagnets, when the appropriate spark gaps are in alignment,  
to effect the discharge of capacitors through juxtaposed pairs of rotor/stator electromagnets. The repulsion  
moves the rotor electromagnet from the stator electromagnet to the next alignment position 40 degrees further on.  
In the interval, until another rotor electromagnet, 120 degrees removed, is aligned with the stator electromagnet  
which had just been pulsed, the associated capacitor is recharged. Thus, the rotor moves from one position to  
the next, with capacitor discharges occurring each 40 degrees of rotation, a total of nine per revolution. It should  
be obvious that, with other rotor/stator combinations, the number of electromagnet coincidences and spark-gap  
discharges will vary. For example, with the coil pairs shown in Figs 4 through 8, a total of 27 discharges will  
occur. Although there are 18 stator electromagnets and 3 rotor electromagnets, the discharge pattern is  
determined by the specific spark gap arrangement.

The rotor/stator configuration of Fig.5 and Fig.8, involving the major and minor pairs of electromagnets, such as  
85a and 104a (the terms “minor” and “major” referring to the difference in size of the elements), include nine pairs  
of electromagnets in the stator, such as 104a, with three electromagnet pairs of the rotor, such as 85a. Because  
of the 13.33 degree separation between the major and minor electromagnets in the rotor pair 85a, with the same  
separation of minor and major electromagnets of the stator pair 104a, the sequence of rotation and discharge  
described above, with respect to the illustrative example of Fig.5, involves the following:  
1\. A minor element 117 of stator pair 104a is aligned with the minor element 91 of rotor pair 85a. On the  
discharge, this moves the rotor ahead 13.33 degrees.  
2\. the major rotor element 122 of the pair 85a, now is aligned with the major stator element 120b of the next stator  
electromagnet pair, in the stator array as shown in Fig.6. On the discharge, the rotor moves ahead 13.33  
degrees.  
3\. This brings the minor rotor electromagnet 91 into alignment with the major stator electromagnet 120b of pair  
104d, and the major electromagnet 122 (just discharged) of pair 85a into alignment with minor electromagnet  
117b of pair 104d, and the rotor spark gap elements into alignment with a different position of gap elements  
connected with capacitors not discharged in the previous position of the rotor. It should be remembered at this  
point that it is the positioning of a rotatable spark gap array, similar to that illustrated in Fig.17 and Fig.18, which  
controls the time of discharge of capacitors connected to these gap terminals. Therefore, any electromagnet can  
be energised twice, successively, from separate capacitors as the rotor brings appropriate gap terminals into  
alignment with the coil terminals of a particular electromagnet.

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S01009)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/1009) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
