Source page 1050 · section 1081/1965 · approximately 3 minutes
A - 204
A - 204
(6) For 1400 RPM for 2300T coil with 24 gauge wire and 0.5" core:
(a) CM:
0.58v / 2.4 mA = 241.667 ohms = Z
(b) SI:
8.3v / 7.8 mA = 1065.385 ohms = Z
(7) For 400 RPM for 2300T coil with 24 gauge wire and 0.75" core:
(a) CM:
0.23v / 4.2 mA = 54.762 ohms = Z
(b) SI:
0.37v / 7.2 mA = 51.389 ohms = Z
(8) For 1200 RPM for 2300T coil with 24 gauge wire and 0.75" core:
(a) CM:
0.79v / 3.4 mA = 232.353 ohms = Z
(b) SI:
0.43v / 6.9 mA = 207.246 ohms = Z
(9) For 1400 RPM for 2300T coil with 24 gauge wire and 0.75" core:
(a) CM:
0.79v / 3.21 A = 246.875 ohms = Z
(b) SI:
2.1v / 2.7 mA = 777.778 ohms = Z
(10) For 400 RPM for 6000T coil with 28 gauge wire and 0.5" core:
(a) CM:
0.49v / 2 mA = 245 ohms = Z
(b) SI:
5.48v / 0.13 mA = 421.538 ohms = Z
(11) For 1200 RPM for 6000T coil with 28 gauge wire and 0.5" core:
(a) CM:
1.25v / 1.5 mA = 833.333 ohms = Z
(b) SI:
15.04v / 4.1 mA = 3668.293 ohms = Z
(12) For 1400 RPM for 6000T coil with 28 gauge wire and 0.5" core:
(a) CM:
2.08v / 1.1 mA = 1890.909 ohms = Z
(b) SI:
18.76v / 2.5 mA = 7504 ohms = Z
(13) For 400 RPM for 6000T coil with 28 gauge wire and 0.75" core:
(a) CM:
0.64v / 1.7 mA = 376.471 ohms = Z
(b) SI:
7.97v / 7.4 mA = 1077.027 ohms = Z
(14) For 1200 RPM for 6000T coil with 28 gauge wire and 0.75" core:
(a) CM:
2.08v / 1.3 mA = 1600 ohms = Z
(b) SI:
20.4v / 5.6 mA = 3642.857 ohms = Z
(15) For 1400 RPM for 6000T coil with 28 gauge wire and 0.75" core:
(a) CM:
2.28v / 1.2 mA = 1900 ohms = Z
(b) SI:
28.4v / 2.1 mA = 13523.81 ohms = Z
It is noted that, based upon the variations of wire size, core size and number of turns, the following effects take
place:
(a) the smaller the wire size the higher the gains regardless of speed;
(b) the greater the number of turns, generally the higher the gains; and
(c) the smaller the core size the higher the gains.
However, when comparing coils with smaller cores but a higher number of turns, the effects stay about the same.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.