REJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITY

science · SOURCE BATCH2-006

A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

Open first-party PDF viewer

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

Contents and coverage · All reading editions · Explanatory guides · Source metadata

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Full commentary and investigation questions

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 112 · section 114/1965 · approximately 4 minutes

3 - 15

3 - 15
5. The device can be started in self-powered mode by briefly applying 9 Volts to the drive coils.
6. The device can be stopped by momentary interruption of the power to the power coils.
7. Conventional instruments operate normally up to an output of 1 kW but stop working above that output
level, with their readings showing zero or some other spurious reading.

Information is limited, but it appears that Floyd’s device was comprised of one or two large ferrite permanent
magnets (grade 8, size 150 mm x 100 mm x 25 mm) with coils wound in three planes mutually at right
angles to each other (i.e. in the x, y and z axes). The magnetisation of the ferrite magnets is modified by
suddenly applying 20,000 Volts from a bank of capacitors (510 Joules) or more to plates on each side of it
while simultaneously driving a 1 Amp 60 Hz (or 50 Hz) alternating current through the energising coil. The
alternating current should be at the frequency required for the output. The voltage pulse to the plates should
be applied at the instant when the ‘A’ coil voltage reaches a peak. This needs to be initiated electronically.

It is said that the powering of the plates causes the magnetic material to resonate for a period of about
fifteen minutes, and that the applied voltage in the energising coil modifies the positioning of the newly
formed poles of the magnet so that it will in future, resonate at that frequency and voltage. It is important
that the voltage applied to the energising coil in this ‘conditioning’ process be a perfect sinewave. Shock, or
outside influence can destroy the ‘conditioning’ but it can be reinstated by repeating the conditioning
process. It should be noted that the conditioning process may not be successful at the first attempt but
repeating the process on the same magnet is usually successful. Once conditioning is completed, the
capacitors are no longer needed. The device then only needs a few milliwatts of 60 Hz applied to the input
coil to give up to 1.5 kW at 60 Hz at the output coil. The output coil can then supply the input coil indefinitely.

The conditioning process modifies the magnetisation of the ferrite slab. Before the process the North pole is
on one face of the magnet and the South pole on the opposite face. After conditioning, the South pole does
not stop at the mid point but extends to the outer edges of the North pole face, extending inwards from the
edge by about 6 mm. Also, there is a magnetic ‘bubble’ created in the middle of the North pole face and the
position of this ‘bubble’ moves when another magnet is brought near it.

The conditioned slab has three coil windings:

1. The ‘A’ coil is wound first around the outer perimeter, each turn being 150 + 100 + 150 + 100 = 500 mm
long (plus a small amount caused by the thickness of the coil former material). It has about 600 turns of 28
AWG (0.3 mm) wire.

2. The ‘B’ coil is wound across the 100 mm faces, so one turn is about 100 + 25 + 100 + 25 = 250 mm (plus
a small amount for the former thickness and clearing coil ‘A’). It has between 200 and 500 turns of 20 AWG
(1 mm) wire.

3. The ‘C’ coil is wound along the 150 mm face, so one turn is 150 + 25 + 150 + 25 = 350 mm (plus the
former thickness, plus clearance for coil ‘A’ and coil ‘B’). It has between 200 and 500 turns of 20 AWG (1
mm) wire and should match the resistance of coil ‘B’ as closely as possible.

Coil ‘A’ is the input coil. Coil ‘B’ is the output coil. Coil ‘C’ is used for the conditioning and for the production
of gravitational effects.

Much of this information and photographs of the original device can be found on the website:
“http://www.intalek.com/Index/Projects/Research/Construction%20of%20the%20Floyd%20Sweet's%20VTA
%20by%20Michael%20Watson.htm” where a paper by Michael Watson gives much practical information.
For example, he states that an experimental set up which he made, had the ‘A’ coil with a resistance of 70
ohms and an inductance of 63 mH, the ‘B’ coil, wound with 23 AWG wire with a resistance of 4.95 ohms and
an inductance of 1.735 mH, and the ‘C’ coil, also wound with 23 AWG wire, with a resistance of 5.05 ohms
and an inductance of 1.78 mH.

This full section as JSON

Congratulations. You’ve won a support ticket.

Your prize is an email address. No purchase required—but coffee helps keep this place online.

Open a support ticket: azmin@zedec.ai

Support and privacy requests are free. Response times are not guaranteed.

The ceremonial small print

“Due to unusual call volume and support volume, we are experiencing longer than normal wait times for a response.” This is our satirical holding message, not a measured queue report. We offer email support.

America runs on coffee, Britain puts the kettle on, and the opium trade reminds us that empires have had considerably worse business plans.

Donation is optional. No prize draw, purchase verification or guaranteed response is involved. Mandatory legal response duties still apply.

Public-interest research, not a spy drop. We keep 18 U.S.C. § 793 on the reading list—and restricted material off the guest list.

Site support and inquiries are welcome: azmin@zedec.ai. We reserve the right to remain silent, subject to legally required responses.