Source page 1215 · section 1255/1965 · approximately 3 minutes
A - 369
A - 369
In Fig.2 a device 40 having the same magnetic flux producing member 12 with magnetic poles 14 and 16 is
shown. Pole pieces 42 and 44 are positioned adjacent respective pole faces 14 and 16 to provide two paths, as
opposed to one above, for the magnetic flux of member 12. In particular, pole piece 42 includes a first path
portion 46 extending beyond a perimeter of north pole face 14 in one direction and a second path portion 48
extending beyond the perimeter of north pole face 14 in another direction. Similarly, pole piece 44 includes a first
path portion 50 extending beyond the perimeter of south pole face 16 in one direction and a second path portion
52 extending beyond the perimeter of south pole face 16 in another direction. Each pole piece path portion 46,
48, 50, 52 includes a respective end face. A first armature 54 which can be positioned adjacent to the end faces
of pole piece path components 48 and 52 provides a first magnetic flux path 56 and a second armature 58 is
which can be positioned adjacent the end faces of pole piece path components 46 and 50 provides a second
magnetic flux path 60. If the flux carrying area along flux paths 56 and 60 is the same as the flux carrying area
along flux path 32 of Fig.1, the magnetic flux density along each flux path 56 and 60 will be one-half the magnetic
flux density along flux path 32 of Fig.1 because the same amount of flux is split between two like paths. The
effect of dividing a given amount of magnetic flux along two like flux paths instead of it passing along just one flux
path can be seen by examining the holding force on armature 54 as compared to the holding force on armature
26 of Fig.1. As already noted the magnetic flux density along path 56 will be one-half that along flux path 32 and
thus the total holding force FT54 can be determined as:
It is therefore seen that dividing the same amount of magnetic flux along two flux paths rather than along one flux
path reduces the magnetic holding or coupling force on an armature to one-fourth rather than one-half as might
have been expected. This unexpected magnetic holding or coupling force differential, resulting from multiple flux
paths, can provide advantageous properties in linear, reciprocating, and rotary motion devices.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.