REJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITY

science · SOURCE BATCH2-006

A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

Open first-party PDF viewer

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

Contents and coverage · All reading editions · Explanatory guides · Source metadata

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Full commentary and investigation questions

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 1217 · section 1257/1965 · approximately 3 minutes

A - 371

A - 371
pole pieces 94, 96 due to the resulting magnetic coupling forces. However, if coils 100, 102 are energised to
provide an equal but opposing magnetic flux to that of permanent magnet 92, the result is that the magnetic flux of
permanent magnet 92 is blocked and no magnetic flux traverses the path which includes armature 98 and
therefore no magnetic coupling forces act on armature 98 allowing it to fall away as shown in Fig.6. The
permanent magnet device 90 is useful, although as will become apparent below, it is more advantageous to
provide multiple flux paths rather than one.

In this regard, in Fig.7 a permanent magnet device 110 includes a permanent magnet 112 having pole pieces
114, 116 positioned adjacent the pole faces of it, with armatures 118, 120 completing two low-reluctance paths
130, 132 from pole to pole thereof. Control coils 122, 124 are positioned along path 130 and control coils 126,
128 are positioned along path 132. The two paths provided are assumed to be of equal reluctance. With no coils
energised, the magnetic flux of permanent magnet 112 divides equally along flux path 130 and flux path 132 such
that both armatures 118, 120 are subjected to a magnetic coupling force which holds them in place against pole
pieces 114, 116.

If coils 122, 124 are energised to provide a magnetic flux equal to but opposing the magnetic flux which travels
along flux path 130 from permanent magnet 112 when no coils are energised, the result is that the magnetic flux
of permanent magnet 112 is blocked and no magnetic flux traverses the path which includes armature 118 and
therefore no magnetic coupling forces act on armature 118 allowing it to fall away as shown in Fig.8. Further, the
magnetic flux traversing path 132 will be double that of when no coils are energised and therefore the magnetic
coupling force on armature 120 will be about four (4) times that of when no coils are energised. By energising
coils 126, 128 in an opposing manner a similar result would be achieved such that armature 120 would fall away
and such that the magnetic coupling force on armature 118 would be increased.

If coils 122, 124 are energised to provide a magnetic flux equal to and aiding the magnetic flux which travels along
flux path 130 when no coils are energised, the result is that the control coils couple completely with the magnetic
flux of permanent magnet 112 and no magnetic flux traverses the path which includes armature 120 and therefore
no magnetic coupling forces act on armature 120 allowing it to fall away as shown in Fig.9. Further, the magnetic
flux traversing path 130 will be double that of when no coils are energised and therefore the magnetic coupling
force on armature 118 will be about four (4) times that when no coils are energised. By energising coils 126, 128
in an aiding manner a similar result would be achieved such that armature 118 would fall away and the magnetic
coupling force on armature 120 would be increased.

Based on the foregoing, it is seen that the full magnetic coupling force available from the permanent magnet 112,
can be switched from one path to another path by the application of one half the power it would require for a coil
alone to produce the same magnetic flux along one path. The ability to switch the full magnetic coupling force
easily from one path to another, allows for efficient reciprocating, linear, and rotary motion and power conversion
to be achieved.

This full section as JSON

Congratulations. You’ve won a support ticket.

Your prize is an email address. No purchase required—but coffee helps keep this place online.

Open a support ticket: azmin@zedec.ai

Support and privacy requests are free. Response times are not guaranteed.

The ceremonial small print

“Due to unusual call volume and support volume, we are experiencing longer than normal wait times for a response.” This is our satirical holding message, not a measured queue report. We offer email support.

America runs on coffee, Britain puts the kettle on, and the opium trade reminds us that empires have had considerably worse business plans.

Donation is optional. No prize draw, purchase verification or guaranteed response is involved. Mandatory legal response duties still apply.

Public-interest research, not a spy drop. We keep 18 U.S.C. § 793 on the reading list—and restricted material off the guest list.

Site support and inquiries are welcome: azmin@zedec.ai. We reserve the right to remain silent, subject to legally required responses.