Source page 1230 · section 1270/1965 · approximately 2 minutes
A - 384
A - 384
Pole piece 444 includes five path portions 448A-448E which extend beyond the edge of the north pole face of
permanent magnet 442 to one side of it and at respective positions along it’s length, and it has path portion 448A-
448E each with a control coil 450A-450E positioned around them. Pole piece 446 includes one portion 452
extending beyond the edge of the south pole face of permanent magnet 442 to the one side of it, and this portion
452 extends along the entire length of permanent magnet 442. A number of armatures 454 define a path of
relative movement between permanent magnet control component 440 and such armatures 454, and by providing
timed energisation of given control coils 450A-450E such relative movement can be achieved.
The sequence of side views depicted in Figs.18C-18E illustrate such relative movement,
with coils 450A, 450C and 450E being energised in an opposing manner simultaneously in Fig.18C,
with coils 450A and 450D being energised simultaneously in an opposing manner in Fig.18D, and
with coils 450B and 450D being energised simultaneously in an opposing manner in Fig.18E.
In Fig.18C, magnetic flux will only flow along path portions 448B and 448C of pole piece 444 causing resultant
magnetic coupling forces depicted by arrows 456, 458 which act to move permanent magnet control component
440 to the left, assuming armatures 454 are fixed. Similarly, due to the timing of subsequent coil energisation
resultant magnetic forces depicted by arrows 460, 462 in Fig.18D and arrows 464, 466 in Fig.18E act to continue
movement of permanent magnet control component 440 to the left. Thus, if permanent magnet control
component 440 were fixed to a device or structure, controlled movement of the device or structure along the path
defined by armatures 454 could be achieved. Conversely, if permanent magnet control component 440 were
fixed and armatures 454 were located on a device or structure, controlled movement of the device or structure
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.