canonical: "https://yogababe.online/reading/BATCH2-006/1287"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 1287 · A - 401 | Rejuvenati"
content_sha256: "0e4b5a9456911706e8e843cebc636beaa2c3d83f0d82eff73d0dd868dd3400f9"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 1247 · section 1287/1965 · approximately 3 minutes

## A - 401

A - 401

With continuous flux paths the static flux from the permanent magnet or magnets is useless. However, if the  
static flux of the permanent magnet confined to the flux paths were modified to be time varying it would have utility  
for electromagnetic induction devices for power conversion like transformers and power inverters. However, the  
same basic method for controlling the flux of a permanent magnet to provide linear and rotary motion can also be  
applied to time varying the static flux from the permanent magnet. The construction shown in Fig.45X utilises four  
control coils and a single permanent magnet while the construction shown in Fig.45A uses two control coils and  
two permanent magnets. The flux that would normally be supplied by a primary winding is supplied by the static  
flux of the permanent magnet or magnets and the control coils convert this static flux into a time varying flux in a  
novel way. Both arrangements use two secondary coils, the secondary coils are placed in the region of the  
continuous flux path that would be occupied by an armature or rotor in the linear or rotary arrangements. The  
regions of the flux paths that perform work are the same in all cases.

In all cases the control coils can either be wired in series or parallel and the secondary coils can be either wound  
in series or parallel. More than one secondary coil or secondary coils with multiple taps can be placed in the  
working regions and further multiple flux paths can be utilised with one or more secondary coils placed in each of  
the working regions. This is made obvious by the disclosures of the linear and rotary devices herein and based  
on the fact that the working regions of the flux paths are identical.

Fig.45X and Fig.45A also show the paths of the static flux of the permanent magnet or magnets when no current  
is flowing in the control coils. In the arrangement shown in Fig.45X the flux from the single permanent magnet  
divides between the two working areas of the flux path. In the arrangement of Fig.45A all of the flux of one of the  
permanent magnets passes through one of the working regions and all of the flux of the second permanent  
magnet passes through the other working region. Each of the working regions in both cases are occupied by  
secondary coils.

Fig.45Y and Fig.45B show the control coils energised with the polarity shown with respect to the polarity of the  
permanent magnet or magnets included. In Fig.45Y the opposing coil, blocks the passage of flux from the  
permanent magnet, and the aiding coil couples with the flux of the permanent magnet and therefore all of the flux  
of the permanent magnet passes through one working region as shown. In Fig.45B the opposing side of the coil  
blocks the passage of flux from the permanent magnet on the opposing side of the coil and the aiding side of the

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S01287)

---