---
canonical: "https://yogababe.online/reading/BATCH2-006/1364"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 1364 · A - 471 | Rejuvenati"
content_sha256: "66497892bab42e519b593ec186608af61dc8f385463c793b1b01654dcccbce0a"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 1317 · section 1364/1965 · approximately 5 minutes

## A - 471

A - 471  
claim to have the highest power-per-pound ratio of any battery. See Table 1 below for comparisons among the  
various batteries. What is lost in the cost translation is the fact that NiMH batteries yield nearly twice the  
performance (energy density per weight of the battery) than do conventional lead-acid batteries. A major  
drawback to the NiMH battery is the very high self-discharge rate of approximately 5% to 10% per day. This  
would make the battery useless in a few weeks. The Ni-Cad battery and the lead-acid battery also have self-  
discharge but it is in the range of about 1% per day and both contain hazardous materials such as acid or highly  
toxic cadmium. The Ni-Z and the NiMH batteries contain potassium hydroxide and this electrolyte in moderate  
and high concentrations is very caustic and will cause severe burns to tissue and corrosion to many metals such  
as beryllium, magnesium, aluminium, zinc, and tin.

Another factor that must be considered when making a battery comparison is the recharge time. Lead-acid  
batteries require a very long recharge period, as long as 6 to 8 hours. Lead-acid batteries, because of their  
chemical makeup, cannot sustain high current or voltage continuously during charging. The lead plates within the  
battery heat rapidly and cool very slowly. Too much heat results in a condition known as "gassing" where  
hydrogen and oxygen gases are released from the battery's vent cap. Over time, gassing reduces the  
effectiveness of the battery and also increases the need for battery maintenance, i.e., requiring periodic de-  
ionised or distilled water addition. Batteries such as Ni-Cad and NiMH are not as susceptible to heat and can be  
recharged in less time, allowing for high current or voltage changes which can bring the battery from a 20% state  
of charge to an 80% state of charge in just 20 minutes. The time to fully recharge these batteries can be more  
than an hour. Common to all present day batteries is a finite life, and if they are fully discharged and recharged  
on a regular basis their life is reduced considerably.

SUMMARY OF THE INVENTION  
In accordance with the illustrated preferred embodiment, the present invention provides a unique electrical-  
energy-storage unit that has the capability to store ultra high amounts of energy.

One aspect of the present invention is that the materials used to produce the energy-storage unit, EESU, are not  
explosive, corrosive, or hazardous. The basis material, a high-permittivity calcined composition-modified barium  
titanate powder is an inert powder and is described in the following references: S. A. Bruno, D. K. Swanson, and I.  
Burn, J. Am Ceram. Soc. 76, 1233 (1993); P. Hansen, U.S. Pat. No. 6,078,494, issued Jun. 20, 2000. The most  
cost-effective metal that can be used for the conduction paths is nickel. Nickel as a metal is not hazardous and  
only becomes a problem if it is in solution such as in deposition of electroless nickel. None of the EESU materials  
will explode when being recharged or impacted. Thus the EESU is a safe product when used in electric vehicles,  
buses, bicycles, tractors, or any device that is used for transportation or to perform work. It could also be used for  
storing electrical power generated from solar voltaic cells or other alternative sources for residential, commercial,  
or industrial applications. The EESU will also allow power averaging of power plants utilising SPVC or wind  
technology and will have the capability to provide this function by storing sufficient electrical energy so that when  
the sun is not shinning or the wind is not blowing they can meet the energy requirements of residential,  
commercial, and industrial sites.

Another aspect of the present invention is that the EESU initial specifications will not degrade due to being fully  
discharged or recharged. Deep cycling the EESU through the life of any commercial product that may use it will  
not cause the EESU specifications to be degraded. The EESU can also be rapidly charged without damaging the  
material or reducing its life. The cycle time to fully charge a 52 kWH EESU would be in the range of 4 to 6  
minutes with sufficient cooling of the power cables and connections. This and the ability of a bank of EESUs to  
store sufficient energy to supply 400 electric vehicles or more with a single charge will allow electrical energy  
stations that have the same features as the present day gasoline stations for the ICE cars. The bank of EESUs  
will store the energy being delivered to it from the present day utility power grid during the night when demand is  
low and then deliver the energy when the demand hits a peak. The EESU energy bank will be charging during  
the peak times but at a rate that is sufficient to provide a full charge of the bank over a 24-hour period or less.  
This method of electrical power averaging would reduce the number of power generating stations required and  
the charging energy could also come from alternative sources. These electrical-energy-delivery stations will not  
have the hazards of the explosive gasoline.

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S01364)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/1364) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
