A - 478
A - 478
Calculation of minimum amount of (CH3)4NOH
required for 100 g of the precursor mixture
Precursor
FW
Wt %
Wt %/FW
Reactant
base
multiplier
Mol of base
required
Ba(NO3)2
261.34
48.09898
0.184048
2
0.368095
Ca(NO3)2.4H2O
236.15
1.81568
0.007689
2
0.015377
Nd(NO3)3.6H2O
438.35
0.21065
0.000481
3
0.001442
Y(NO3)3.4H2O
346.98
0.15300
0.000441
3
0.001323
Mn(CH3COO)2.4H2O
245.08
0.10806
0.000441
2
0.000882
ZrO(NO3)2
231.23
7.34097
0.031747
2
0.063495
[CH3CH(O—)COONH4]2Ti (OH)2
294.08
42.27266
0.143745
2
0.287491
Total:
100.00000
0.738105
Reactant strong base
(CH3)4NOH
91.15
Note: The weight of (CH3)4NOH required is accordingly a minimum of
(0.738105 mol) (91.15 g/mol) = 67.278 g for 100 g of the precursor mixture.
Tetramethylammonium hydroxide (CH3)4NOH is a strong base.
Coating of Aluminium Oxide on Calcined Modified Barium Titanate Powder
Barium titanate BaTiO3
FW 233.19
d 6.080 g/cm3
Aluminium oxide Al2O3
FW 101.96
d 3.980 g/cm3
Precursor, aluminium nitrate nonahydrate, as selected from the reference: Sigma-Aldrich Corp., "Handbook of
Fine Chemicals and Laboratory Equipment", 2000-2001. Al(NO3)3.9H2O FW 3.75.13
For Calcined Aluminium Oxide (Al2O3) Coating of 100 Angstrom units Thickness on Calcined Modified Barium
Titanate Powder 100 Angstrom units = 10-6 cm 1.0 m2 = 104 cm2
area thickness of Al2O3 coating volume (104 cm2/g)(10-6 cm) = 10-2 cm3/g - - - of calcined powder
Al(NO3)3.9H2O (FW 375.13)(2)=750.26
Al2O3 FW 101.96=101.96
750.26/101.96=7.358
For an aluminium oxide (Al2O3) coating of 100 Angstrom units thickness on calcined modified barium titanate
powder with particle volume of 1.0 μm3, 39.8 mg of Al2O3 are required per g of this powder, corresponding to
292.848 mg of the aluminium nitrate nonahydrate [Al(NO3)3.9H2O] precursor required per g of this powder.
Coating of Calcium Magnesium Aluminosilicate Glass on Aluminium Oxide Coated
Calcined Modified Barium Titanate Powder
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.