Source page 1358 · section 1407/1965 · approximately 3 minutes
A - 512
A - 512
E2. The working circuit, consisting of the capacitors 5 and 6 and a resonance motor or a capacitor motor M, such
as already described, is connected in proximity around the sparking gap section 7. Of course, instead of
connecting the capacitor motor directly, the primary circuit for high frequency oscillatory current may also be
inserted.
The capacitor sets are connected by one pole to the annular conductor R and can be either inductionless (16 and
18) or made as induction capacitors as shown by 21 and 23. The free poles of the inductionless capacitors are
indicated by 17 and 19, and those of the induction capacitors by 22 and 24. As may be seen from the drawings,
all of these poles 17, 22, 19 and 24 may be interconnected in parallel through a second annular conductor without
any fear that thereby the principle of the free pole connection will be lost. In addition to the advantages already
mentioned, the parallel connection also allows an equalisation of the working voltage in the entire collector
network. Suitably calculated and constructed induction coils 25 and 26 may also be inserted in the annular
conductor of the free poles, by means of which, a circuit may be formed in the secondary coils 27 and 28 which
allows current produced in this annular conductor by fluctuations of the charges, to be measured or otherwise
utilised.
According to what has already been stated, separate collector balloons may be connected at equidistant stations
distributed over the whole country, either connected directly with one another metallically or by means of
intermediate suitably connected capacitor sets through high voltage conductors insulated from earth. The static
electricity is converted through a spark gap, into high frequency dynamic electricity which may be utilised as a
source of energy by means of a suitable connection method, various precautions being observed, and with
special regulations. The wires leading from the collector balloons, have up to now been connected through an
annular conductor without this endless connection, which can be regarded as an endless induction coil, being
able to exert any action on the whole conductor system.
It has now been found that if the network conductor connecting the aerial collector balloons with one another, is
not made as a simple annular conductor, but preferably short-circuited in the form of coils over a capacitor set or
spark gap or through thermionic valves, then the total collecting network exhibits quite new properties. The
collection of atmospheric electricity is thereby not only increased but an alternating field may easily be produced
in the collector network. Further, the atmospheric electrical forces showing themselves in the higher regions, may
also be obtained directly by induction. In Fig.26 and Fig.28, a form of construction is shown, on the basis of
which, the further foundations of the method will be explained in more detail.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.