Source page 1363 · section 1413/1965 · approximately 5 minutes
A - 517
A - 517
As transformer of the atmospheric electricity, an arrangement is employed which consists of using rotary pairs of
capacitors in which the stator surface B is connected with the main current, while the other A is connected to the
earth pole. These pairs of short-circuited capacitors are caused to rotate and the converted current can be taken
from them via two collector rings and brushes. This current is alternating current with a frequency dependent on
the number of balloons and the rate of revolutions of the rotor. As the alternating current formed in the rotor can
act through coils 10 on the inductor 9, an increase or decrease of the feed current in I can be obtained according
to the direction of the current by back-induction. Current oscillations of uniform rhythm are produced in the coil-
shaped windings of the producer network.
As the ends of this conductor are short-circuited through the regulatable capacitor 19, these rhythms produce
short-circuited undamped oscillations in the energy conductor. The frequency of these oscillations can be altered
at will by adjusting the capacitance of capacitor 19. These currents may also be used as working current via the
conductors II1 and III. By inserting capacitor 20, a connection between these conductors may also be made,
whereby harmonic oscillations of desired wavelength are formed. By this means, quite new effects as regards
current distribution are obtained. The withdrawal of current can even take place without direct wire connection if,
at a suitable point in the interior of the producing network (quite immaterially whether this has a diameter of 1 or
100 km) a coil tuned to these wavelength and of the desired capacity, is firmly or moveably mounted in the aerial
conductor in such a way that its axis is parallel with the axis of the collector coil. In this case, a current is induced
in the producing network, the size of which is dependent on the total capacity and resistance and on the
frequency selected. A future possibility is taking energy from the producer network by radio signals as in addition
to atmospheric electricity, magnetic earth currents and energy from the upper atmosphere may be tapped.
Of course, vacuum tubes may be used to produce undamped oscillations anywhere spark gaps are shown in the
circuits. The separate large-diameter coils of the producer network may be connected to one another through
separate conductors all in parallel or all in series or in groups in series. By regulating the number of oscillations
and the magnitude of the voltage, more or fewer large collector coils of this kind may be used. The coils may also
be divided spirally over the entire section. The coils may be carried out in annular form or in triangular,
quadrangular, hexagonal or octagonal form.
Of course, wires which form guides for the current waves, may be carried from a suitable place to the centre or
also laterally. This is necessary when the currents have to be conducted over mountains and valleys and so forth.
In all these cases, the current must be converted into a current of suitable frequency.
As already mentioned, separate collecting balloons may be directly metallically interconnected a equidistant
stations distributed over the entire country, or may be connected by interpolation of suitable capacitor sets by
means of high voltage conductors. The static electricity is converted through a spark gap into dynamic energy of
high frequency and could then in that form be used as an energy source after special regulation.
According to this invention, in order to increase the collecting effect of the balloon in the aerial collector conductor
or in the earth wire, radiating collectors are used. These consist of either incandescent metal or oxide electrodes
in the form of vacuum grid valves, or electric arcs (mercury or similar electrodes), Nernst lamps, or flames of
various kinds maybe simply connected with the respective conductor.
It is well known that energy can be drawn off from a cathode consisting of an incandescent body opposite an
anode charged with positive electricity (vacuum grid tube). Hitherto however, a cathode was always first directly
placed opposite an anode, and secondly, the system always consisted of a closed circuit.
Now if we dispense with the ordinary ideas in forming light or flame arcs in which a cathode must always stand
directly opposite an anode charged to a high voltage or another body freely floating in the air, or consider the
incandescent cathode to be only a source of unipolar discharge, (which represents group and point discharges in
electro-static machines similar to unipolar discharges), it may be ascertained that incandescent cathodes and less
perfectly, all incandescent radiators, flames and the like, have relatively large current densities and allow large
quantities of electric energy to radiate into open space in the form of electron streams as transmitters.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.