Source page 1402 · section 1463/1965 · approximately 4 minutes
A - 556
A - 556
These results indicate that, when wired as a split-phase motor, the motor rotary velocity varies not as a function of
voltage or current, but as a function of frequency when the phase-splitting capacitance is fixed within a suitable
range, there being an optimum frequency mode for each value of suitable capacitance, with lower values of
capacitance favouring higher frequency modes. For a given frequency and capacitance, the motor rotary velocity
remains essentially constant and independent from voltage and current input, and thus at a plateau. Torque, in
the same circuit arrangement, follows exactly the same pattern as rotary velocity, as a function of input frequency
at a fixed potential. Torque is linearly proportional to rpm in these motors when they are split-phase wired, and
rpm linearly proportional to CW frequency, which makes them ideal for experimentation and determination of
power output computations. Moreover, since these are drag machines, the slip itself determines the rotor currents
and these are susceptible to tuning such that their retardation and relative position in the field can find resonant
modes for varying CW frequency and capacitance.
In the circuit of Fig.17 when using the KS 9303 motor, the inertial damping of the flywheel coupling retards the
motor rotor currents sufficiently to allow them to build up torque, with the entire motor assembly serving as the
preferred sink for all of the energy, mass-free and mass-bound, captured by the receiving coil circuit with a
drawing action established by the motor on the circuit, and providing satisfactory absorption by an inertial damper
of the combined, synchronised, dampened wave impulses, those occurring at a low frequency as a result of the
firing of the PAGD reactor, and those occurring at a higher superimposed frequency -sourced in the transmitter
circuit and picked-up by the receiver plate and coil. The action of each DW impulse train itself generates two
different events: the DC-like auto-electronic-like discontinuity which sets the motor in motion and initiates the rotor
currents, and the AC-like dampened wavetrain which supports the consistency of those rotors. The concentration
of current required to kick-start the motor is provided by the DW impulses of the PAGD reactor, whereas, once the
motor is in motion, and particularly, once it is stabilised by the flywheel, the cumulative action of the higher
frequency DW impulses makes itself felt by accelerating the rotor to an optimum rotary velocity.
For the next series of tests we employed the basic circuit diagram of the improved motor shown in Fig.19. The
transmission station is the typical Tesla transmitter with a line-fed, 60 Hz vibrator stage. At the line input to the
first stage, we place a calibrated AC wattmeter (Weston Model 432), and a Beckman 330B rms ammeter in series
with the hot lead, we set the vibrator stage for 41 clicks, consuming between 28.5W and 35W, depending upon
circumstances yet to be described. This consumption was confirmed by driving the coil from an inverter powered
by a 12 volt battery. The inverter consumes 2.16 watts, and is 90% efficient. The total consumption from the
battery was 42 watts (12V at 3.5A); once the 2.16 watts is deducted and the efficiency taken into account, we
obtain the same 36W (vibrator stage at max., i.e. 47 clicks, in this experiment). The T/R gap is adjusted to 3'', and
2 square foot plates are used. Transmitter and receiver coils are tuned, and so are the plate capacitances, to 250
kHz, also the capacitances of the Function Y circuit connected at the output of the receiving coil.
The rectified voltage and current generated by the transmitter secondary and by the transmitter plate was
ascertained with a coil-tuned wave-divider (Function Y) circuit by loading it with different resistive values. The
results constitute a measure of the mass-bound electrical power output directly from the transmitter apparatus.
The same method was employed to ascertain the voltage, current and power of the mass-bound charges
circulating in the receiving plate and coil circuit. The results are shown in Table 8 below:
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.