reflects the charge accumulation occurring in the charge pack and obtained by capture of energy produced during
PAGD operation, triggered by the energy drawn from the drive pack during load time 2.
As a first approximation of electrical power generated and consumed by the energy conversion system of the
invention, the previous open circuit voltage method is of significance in showing the basic trends involved in
interaction of the operating parameters. However, in all likelihood, it overestimates the actual values of electrical
power consumed and generated, for a variety of reasons. First, it assumes that the relative capacity scale of the
batteries in the drive and charge packs is an absolute charge capacity scale with an invariant maximal charge
retention, which it is not; in fact, the absolute charge capacity is itself a variable subject to several factors, such as
the cycle life, overcharging or undercharged conditions, cell age, residual memory and the rate of charge and
discharge. Hence, the inference of a uniform time scale on the basis of the open circuit voltage/capacity
intercepts may not be warranted. Finally, it does not integrate the open voltage decrease over time, and utilises
the specification load current as the average current over time.
In order to obviate these problems, we resorted to a variety of other measurement methods. First, we proceeded
to compare the closed circuit, preliminary, resistive-load discharge measurements for either charge or drive pack,
under conditions of negligible loss of power, as these measurements were statistical means (n = 9) taken, at
equal intervals, during the first 90 seconds of the load discharge, and obtained both just before the PAGD
production runs (but separated from each PAGD run by an open circuit voltage relaxation of 30 minutes) and just
after the runs (but equally separated by a relaxation of 30 minutes). As an example of the data generated by
such an approach, Fig.14 illustrates the shift of the slopes indicating marginal power loss for the drive pack (from
the closed squares to the open squares) and those indicating gain of power for the charge pack (from the open
circles to the closed circles), in actual total load power values.
Integration of these power measurements over the projected load discharge time, taken from the family of curves
generated on the basis of the manufacturer's load voltage over discharge time specifications, led to a direct
comparison of the new values, as shown in Table 6, with the values presented in Table 5, for the first three
instances introduced. All values of Table 6 were obtained by resistive measurements of power that entailed a
negligible power loss. Table 6 confirms the fundamental equivalence of runs 1 through 3, as already seen from
their corresponding analysis using the open voltage method (see runs 1 to 3, Table 5). This new power estimation
method also confirms the lower loss encountered in run 2 utilising interrupted PAGD operation. While the break-
even efficiencies sensibly doubled using this method, the estimates of actual electrical power consumption
recovery decreased by a 2 to 3-fold factor. Thus this direct load voltage/amperage measurement method of
estimating actual power losses or gains, is a check upon the open voltage method previously utilised.
Direct, instantaneous measurements of the voltage and current characteristics of the PAGD production and
capture phenomena being discussed, were also performed during PAGD runs for diverse sets of conditions,
including all those described in the two previous sections. In Table 7 we show these results for two PAGD
generators having an identical electrode area (128 cm2) and connected to electrical energy capture circuits of
three separate configurations as set forth in Fig.10A, Fig.10B and Fig.10C and column 2, Table 7. In the
configuration of Fig.10C, or double diode configuration, both electrode plates act as cathodes and the axial
member as the anode collector (experiments 1-4, for the H220 device and 13-14, Table 7, for the H34 device). In
the configuration of Fig.10B, or triode configuration, one plate acts as the cathode, the axial member as an
auxiliary cathode and the other plate as a collector (experiments 5-9, Table 7). In the configuration of Fig.10A or
single (plate to plate) diode configuration, the axial member is disconnected, and the polarity of the plates remain
as in the triode configuration (experiments 10-12). All measurements were taken after 1 minute of PAGD
operation of the devices, which were, at the start of each run, at room temperature. All cathodes had been
previously broken in with > 2 x 106 AGD pulses. The open circuit voltage of the charge pack was, for all cases, at
359 to 365 volts, before each test. The direct measurements of the PAGD input and output DC voltages and
currents were obtained as statistical means of 10 second long measurements, and at no time did the standard
error of the plate voltage mean exceed 35 volts.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.