A - 584
A - 584
Data from runs 1 through 4 demonstrate that, at these PAGD frequencies, there is no difference between using
fast switching (32 nanoseconds) MUR 860 diodes, or regular 40HFR-120 silicon diodes, in the rectification bridge
of the electrical energy capture circuit, and that the PAGD frequency varies as a function of decreasing air
pressure.
Runs 5 to 14 show that, in general, for the same tube, the single and double diode configurations are the most
efficient, for the same pressure, the diode configuration typically yields some 1.5 to 2 times larger break-even
efficiencies (cp runs 10-11 and 13-14, with runs 5-9, Table 7). The largest accumulations of power are also
registered in the diode mode(s). This trend appears to be a function of the much lower cathodic work-function of
the aluminium plates, than of the tungsten of the axial member utilised as an auxiliary cathode in the triode
configuration. A feature of the data from these 14 different runs is the consistent excess power outputs (column
15, Table 7) and their narrower range (218 to 563%), when compared to those observed with the previous two
methods of experimental analysis.
Run 12, Table 7, shows that the switching on of the electromechanical arm can be performed without entailing a
power loss in the PAGD capture circuit, as previously found for run 5, Table 5, utilising the open circuit voltage
method. In fact, with C4 = 8 microfarads and R4 = 500 ohms, the AC induction motor behaves as an electrical
flywheel (e.g. 2800-3000 rpm for 10 PPS inputs), while the electrical energy capture circuit still registers a
sizeable excess electrical power production (compare runs 11 and 12, Table 7). Runs 13 and 14 illustrate how
the charge pack's state of charge and its inherent capacitance affects both the PAGD frequency and the power
producing efficiency of the entire system: as the charge pack is reduced from 29 to 19 cells, the PAGD generator
adjusts by reducing its frequency logarithmically and, while the charge pack input current is greater than before,
the drive pack loss becomes still larger and the break-even efficiency much lower (by >1/2, from 563% to 228%).
This is because the circuit must translate the naturally larger PAGD amplitude into a larger surplus of output
current, and in this process becomes less efficient.
If the first measurement method employed (the open circuit method) had to make too many theoretical
assumptions about the system's performance under load conditions and hence about its effective charge
capacity, the second approach still had to suppose an invariant discharge time and thus an invariant absolute
charge capacity on the part of the battery systems (charge packs) employed for capture which it approximated by
an operation of integral calculus. With the third method described above, theoretical assumptions were avoided
except that, in these measurements, the actual performance of a given battery in terms of time, time of delivery
and time of capture, was also ignored; no account is taken of the time-dependent modulation of the PAGD
frequency, as effected by certain of the parameters analysed, namely the charge pack state of charge, the
method of sequencing the PAGD runs (continuous vs interrupted) and its concomitant heating effects, and the
state of charge (load voltage and current capacity) of the drive pack. A simple, non-negligible, resistive
measurement of power lost by the drive pack, and an identically non-negligible measurement of the power gained
by the charge pack, for the same experiment and the same singular time of PAGD production, were performed
repeatedly to corroborate the previous three approaches. For this purpose, all experiments were designed as a
continuous series of sequential phases:
1) Before a PAGD run, a resistive discharge was measured across either pack over periods of 1 to 3 hours
(utilising the DP and CP resistances previously reported in the open voltage section) and followed by a 15 to 30
minute open circuit voltage relaxation;
2) Then, the PAGD runs were performed, either continuously or as interrupted, composite sequences, and the
corresponding open circuit relaxation voltage(s) were measured, after the cessation of the integral PAGD run;
3) Finally, resistive discharge measurements, obtained under identical conditions to those recorded before the
PAGD run, were carried out for either pack, followed by concomitant battery voltage relaxation rate
measurements.
Under these experimental conditions, exact power measurements could be taken from an analysis of the actual
battery discharge curves before and after the PAGD run. Based on a comparison of the curve trends of the pre-
run resistive discharge of the drive pack with those of the post-run resistive discharge, the effective power drawn
(DeltaEc) from the withdrawable power capacity of the drive pack incurred during a PAGD run, was ascertained.
This represents the power consumption during the run, and the experimental value thus recorded constitutes the
actual power figure that must be matched for break-even to occur. Hence, the break-even value equals, by
definition, the electrical energy input to the system. Similarly, a comparison of the charge pack pre-run and post-
run resistive discharge curve trends identified the effective power (DeltaErho) added to the withdrawable capacity
of the charge pack. This quantity represents the electrical energy recovered during the run. The relation for the
two quantities is expressed by the break-even efficiency equation:
% = DeltaErho / DeltaEc x 100
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.