---
canonical: "https://yogababe.online/reading/BATCH2-006/1499"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 1499 · A - 585 | Rejuvenati"
content_sha256: "ae9092ee2199576b0040c2c03c415b13c7e14cd92974b9f9d86935e9a4b3d324"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 1431 · section 1499/1965 · approximately 5 minutes

## A - 585

A - 585

If the break-even efficiency is less than 100%, then the apparatus registers a net loss in electrical energy in the  
CP with respect to the DP. Conversely, if the efficiency exceeds 100%, then there is a net gain in electrical  
energy in the CP, as compared to that lost in the DP. For purposes of this analysis, a limit to the minimum  
withdrawable capacity was placed, from experiment and in agreement with the load current curves of the  
manufacturer, at 115 W for the driver pack (average current of 0.250 A, minimum current of 0.230 A), and at 90 W  
for the charge pack (average current of 0.375 A, minimum current of 0.334 A), as a function of both their total cell  
size (respectively, 46:29) and the difference in the resistive loads employed for the discharge measurements. All  
cathodes had been broken in, as described before.

The results obtained with this fourth method, for six selected experiments with three diverse types of devices  
(using different electrode plate areas, gap lengths, and electrode work-functions), configured both in the triode or  
the (single) diode (e.g. Fig.10B) arrangements, at the indicated pressures, are presented in Table 8. In all cases,  
a net excess of combined battery pack charge, expressed as electrical watt hours, is registered (columns 8 and  
10, Table 8) and the break-even efficiencies are all >100% (column 10). Experimental groups 1 and 2 again  
demonstrate that, for the same cathode, the interrupted PAGD sequence method of group 2 (1 minute of PAGD  
function, followed by a 15 minute relaxation, and so on) yields a higher break-even efficiency because of the lower  
losses registered with this minimal plate heating method (column 10, Table 8). Group 3 of Table 8, shows that  
the PAGD power production efficiency is also higher for a lower work-function cathode material (H220 vs H34),  
being subjected to PAGD auto-electronic conditions at a 4-fold lower pressure than the control groups 1 and 2;  
however, the lower pressure depresses the frequency and, together with the interrupted PAGD sequencing  
method, it also lowers the loss, causing an actually much larger break-even value than registered for the previous  
two groups. Groups 4 and 5 exemplify the dual effect of lowering both the plate area and the gap distance: the  
former affects the PAGD event frequency, whereas the latter affects the PAGD amplitude, and thus the capture  
efficiency of the charge pack. Despite a cathodic work-function practically and operationally identical to that of  
groups 1 and 2, these smaller plate area and shorter gap devices utilised in groups 4 and 5, yield 3- to 6-fold  
lower net power outputs, as well as lower break-even efficiencies, than the former groups, at the same pressure.  
Finally, group 6 exemplifies the results obtained for the plate diode configuration, where the frequency is lower (no  
triggering role for the axial member), and a higher loss leads to the lower break-even efficiency, comparable to  
that of the lower area and shorter gap groups 4 and 5.

In order to verify the discharge curve lengths employed in these analyses and experimentally establish the actual  
charge capacity of the battery packs, calibration resistive discharges, between the maximum charge state and the  
minimum limits chosen, were performed for each pack with their respective discharge resistances R2 and R3 (see  
Fig.9). These discharge calibration curves were plotted for half maximal charge values shown in Fig.15A and  
Fig.15B, and from the curve produced, we have determined the total half-charge capacities of each battery pack  
to be 1.033 kWh (100%=2.066 kWh) for the drive pack and 660 WHr (100%=1.320 kWh) for the charge pack.  
Based upon the corresponding maximal (100%) capacity values, we determined the actual percentages of the  
relative charge capacities shown in column 5, Table 8, which correspond to the experimental values obtained.  
We also noted that the curves plotted showed two quite distinct time linear slopes, the slope of the delivery of  
power per time unit steepening very markedly at the approach to the limits of the permissible withdrawable  
capacity, occurring at 115 W into R2, and 90 W into R3.

The pre-PAGD run and post-PAGD run, drive and charge pack discharge curves corresponding to groups 3 and  
6, respectively for triode and plate diode configurations, in Table 8, are shown in Fig.16 (drive pack) and 17  
(charge pack), for group 3, and in Fig.18 (drive pack) and Fig.19 (charge pack), for group 6. In all cases, the  
open symbols represent the pre-PAGD run discharge curves, whereas the closed symbols represent the post-  
PAGD run discharge curves.

As a further check on these values, a videographic, millisecond analysis of the singular power simultaneities  
occurring at both ends of the system (drive and charge packs) was performed for various 10 second samples of  
diverse PAGD runs. A typical example is shown in Fig.20, which is a sample of the PAGD run designated as 6 in  
Table 8. While the drive pack DC wattage spent as input to PAGD production varied from 36.6 to 57.82 watts, by  
a factor of 1.6 times, the DC wattage entering the charge pack as captured PAGD output varied more  
pronouncedly by a factor of 2.7 times, from 146.4 to 399.6 watts (all meters were in the same selected ranges of  
voltage and current) with the semi-periodic, intermittent character of each singular emission, though within  
specific, ascertainable ranges for both amplitude and current outputs.

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S01499)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/1499) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
