Source page 1436 · section 1508/1965 · approximately 4 minutes
A - 590
A - 590
extinguishing and self-starting, under the conditions we have defined. Furthermore, we have also identified a
novel and unexpected dependency of the periodic pulse rate upon the cathode area. This indicates the presence
of field emission control parameters heretofore unsuspected. It is likely that field fluctuations of the polarised pre-
breakdown field is responsible for eliciting the particular localisations of the auto-electronic emission foci, as well
as what imparts, in a lens-like fashion, the distorted field energy needed for electron surface release. In this
sense, external, electrical or magnetic field fluctuations (e.g. motion of static charges or of constant magnetic
fields) induced by us at pre-breakdown potentials, provoked PAGD emissions and breakdown at these levels.
In general, VAD studies have shown that, for large area electrodes, microgeometry, adsorbed gas layers and gas
impurity contents of the cathode play a role in modulating field emission. In our PAGD studies, the interactions at
the cathode surface and across the cathode potential drop are clearly modulated by:
(1) the nature of residual gases, as shown by our air vs Argon studies;
(2) their pressure,
(3) electrode conditioning,
(4) work-function and
(5) cumulative pulse count, amongst others.
The plasma, in leak-controlled or low pressure PAGD devices, has both residual gas and metallic vapour
substrates. In devices initially closed at high to very high vacua (diffusion pump pressures), the major residual
substrate, whose presence increases with time of operation, is the metallic vapour released from the cathode and
not impacted on to the envelope walls or the anode. It has been previously shown for externally (magnetically or
electrostatically) pulsed plasma accelerators, that the amount of residual gas or vapour left in the inter-electrode
space diminishes with increasing number of consecutive discharges and a growing amount of electrode-insulator
absorption of gas. The effect of such removal of residual gas or vapour is to decrease the vacuum of a sealed
envelope. With high vacuum sealed PAGD generators we have observed that prolonged operation and sputter-
induced mirroring of the envelope causes a progressive disappearance of the discharge, as the voltage potential
needed to trigger it also increases. At the thermocouple, low frequency pulsed abnormal glow discharges can
also be seen to increase the vacuum significantly. These results suggest instead the presence of a pumping
mechanism in the PAGD which is somewhat analogous to that of sputter ion pumps, where collision of ionised
gas molecules with the cathode is responsible for the sputtering of cathode material that either combines with the
gas substrate (`gettering` action) or `plasters over` the inert gas molecules on to the anode (a process known as
`ion burial`). These are the two basic pressure reducing actions of sputtered getter atoms, in ion pumps.
However, in ion sputter pumps, the initiation of the cycle is a function of the presence of high velocity electrons in
the high field plasma of the glow discharge, which are necessary to ionise the gas substrate molecules; also, the
getter material typically has a high work-function for field emission. Hence, the sputtering is due to the secondary
impact of plasma positive ions at the cathode, after plasma ionisation has occurred in the inter-electrode space.
Altogether different is the mechanism of spontaneous, primary electron emission from the cathode, which is
characteristic of the low field PAGD: here, the sputtering is caused by the electronic emission itself and attendant
metallic vaporisation processes. By artificially confining the firing foci to a part of the cathode, we have shown in
the single diode configuration how the PAGD induced sputtering is associated with the cathode auto-electronic
emission mechanism, rather than with the abnormal cathode glow per se, given the localisation of sputtering on to
the emission region of the plate, despite its overall cathode glow saturation.
These observations would thus seem to corroborate the hypothesis of a progressive vacuum increase with the
cumulative number of emitted pulses, were it not for the fact that experiments performed with leak controlled
devices (reported here and in previous studies) show that, when the negative pressure is maintained by balanced
leak admission of air or argon, pulse rates still decrease with cumulative pulse count, and do so neither as a
function of an increase in vacuum, nor as a function of envelope mirroring (unless this is so extensive as to
establish envelope conduction), but rather as a function of processes (generally referred to as conditioning)
inherent to the electrodes, specifically, to the cathode. We have further shown that, for such altered emitter
states, the pressure of the vessel must be increased, not because of an increasing vacuum (precluded by the
controlled gas leak), but because of the effect that residual gases may have in modulating the low field PAGD
emission.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.