REJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITY

science · SOURCE BATCH2-006

A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

Open first-party PDF viewer

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

Contents and coverage · All reading editions · Explanatory guides · Source metadata

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Full commentary and investigation questions

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 1499 · section 1578/1965 · approximately 5 minutes

A - 653

A - 653

The primary coil of the torroid is subject to a 50% duty-cycle pulse. The torroidal pulsing coil provides a voltage
step-up from the pulse generator in excess of five times, although the relative amount of step-up is determined by
pre-selected criteria for a particular application. As the stepped-up pulse enters the first inductor (formed of 100
turns of 24 gauge wire, 1 inch in diameter), an electromagnetic field is formed around the inductor. Voltage is
switched off when the pulse ends, and the field collapses and produces another pulse of the same polarity; i.e.
another positive pulse is formed where the 50% duty-cycle was terminated. Thus, a double pulse frequency is
produced; however, in a pulse train of unipolar pulses, there is a brief time when pulses are not present.

By being so subjected to electrical pulses in the circuit of Fig.2, the water between the capacitor plates
takes on an electrical charge which is increased by a step-charging phenomenon occurring in the water
capacitor.. Voltage continually increases (to about 1000 volts and more) and the water molecules start to
elongate.

The pulse train is then switched off; the voltage across the water capacitor drops to the amount of charge that the
water molecules have taken on, i.e. voltage is maintained across the charged capacitor. The pulse train is then
applied again.

Because a voltage potential applied to a capacitor can perform work, the higher the voltage potential, the more
work is performed by a given capacitor. In an optimum capacitor which is wholly non-conductive, zero current
flow will occur across the capacitor. Thus, in view of an idealised capacitor circuit, the object of the water
capacitor circuit is to prevent electron flow through the circuit, i.e. such as occurs by electron flow or leakage
through a resistive element that produces heat. Electrical leakage in water will occur, however, because of some
residual conductivity and impurities, or ions that may otherwise be present in the water. thus, the water capacitor
is preferably chemically inert. An electrolyte is not added to the water.

In the isolated water bath, the water molecule takes on charge, and the charge increases. The object of the
process is to switch off the co-valent bonding of the water molecule and interrupt the sub-atomic force that binds
the hydrogen and oxygen atoms together to form a molecule, thus causing the hydrogen and oxygen to separate.

Because an electron will only occupy a certain electron shell, the voltage applied to the capacitor affects the
electrical forces inherent in the co-valent bond. As a result of the charge applied by the plates, the applied force
becomes greater than the force of the co-valent bonds between the atoms of the water molecule, and the water
molecule becomes elongated. When this happens, the time share ratio of the electrons between the atoms and
the electron shells, is modified.

In the process, electrons are extracted from the water bath; electrons are not consumed nor are electrons
introduced into the water bath by the circuit, as electrons would be during conventional electrolysis. Nevertheless,
a leakage current through the water may occur. Those hydrogen atoms missing electrons become neutralised
and atoms are liberated from the water. The charged atoms and electrons are attracted to opposite polarity
voltage zones created between the capacitor plates. The electrons formerly shared by atoms in the water co-
valent bond are re-allocated so that neutral elemental gasses are liberated.

In the process, the electrical resonance may be reached at all levels of voltage potential. The overall circuit is
characterised as a “resonant charging choke” circuit which is an inductor in series with a capacitor [SAMS Modern
Dictionary of Electronics, 1984 p.859]. Such a resonant charging choke is on each side of the capacitor. In the
circuit, the diode acts as a switch which allows the magnetic field produced in the inductor to collapse, thereby
doubling the pulse frequency and preventing the capacitor from discharging. In this manner, a continuous voltage
is produced across the capacitor plates in the water bath and the capacitor does not discharge. The water
molecules are thus subjected to a continuously charged field until the breakdown of the co-valent bond occurs.

As noted initially, the capacitance depends on the dielectric properties of the water and the size and separation of
the conductive elements forming the water capacitor.

Example 1
In an example of the circuit of Fig.2 (in which other circuit element specifications are provided above), two
concentric cylinders 4 inches long, formed the water capacitor of the fuel cell in the volume of water. The outside
cylinder was o.75 in outside diameter; the inner cylinder was 0.5 inch in outside diameter. Spacing between the
inside cylinder and the outside cylinder was 0.0625 inch (1.59 mm). Resonance in the circuit was achieved at a
26 volt pulse applied to the primary coil of the torroid at 10khz and a gas mixture of hydrogen, oxygen and
dissolved gasses was given off. The additional gasses included nitrogen and argon from air dissolved in the
water.

This full section as JSON

Congratulations. You’ve won a support ticket.

Your prize is an email address. No purchase required—but coffee helps keep this place online.

Open a support ticket: azmin@zedec.ai

Support and privacy requests are free. Response times are not guaranteed.

The ceremonial small print

“Due to unusual call volume and support volume, we are experiencing longer than normal wait times for a response.” This is our satirical holding message, not a measured queue report. We offer email support.

America runs on coffee, Britain puts the kettle on, and the opium trade reminds us that empires have had considerably worse business plans.

Donation is optional. No prize draw, purchase verification or guaranteed response is involved. Mandatory legal response duties still apply.

Public-interest research, not a spy drop. We keep 18 U.S.C. § 793 on the reading list—and restricted material off the guest list.

Site support and inquiries are welcome: azmin@zedec.ai. We reserve the right to remain silent, subject to legally required responses.