---
canonical: "https://yogababe.online/reading/BATCH2-006/1603"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 1603 · A - 677 | Rejuvenati"
content_sha256: "b267a597cd7d55ce5f71e4259367655d18ffa2e9a4e58a366373315ab152bb77"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 1523 · section 1603/1965 · approximately 4 minutes

## A - 677

A - 677

The circuits are interconnected as shown in Fig.1 and to the pulsing core voltage intensifier circuit of Fig.10,  
which, among other things, isolates the water capacitor electrically so that it becomes an electrically isolated  
cavity for the processing of water in accordance with it’s dielectric resonance properties. By reason of this  
isolation, power consumption in the control and driving circuits is minimised when resonance occurs, and current  
demand is minimised as voltage is maximised in the gas production mode of the water capacitor / Fuel Cell.

The reference letters “A” through “M” and “M1” show, with respect to each separate circuit shown, the point at  
which a connection in that circuit is made to another of the circuits shown.

In the invention, the water capacitor is subjected to a duty pulse which builds up in the resonant charging choke  
coil and then collapses. This occurrence allows a unipolar pulse to be applied to the Fuel Cell capacitor. When a  
resonant condition of the circuit is locked-in by the circuit, current leakage is held to a minimum as the voltage  
which creates the dielectric field tends to infinity. Thus, when high voltage is detected upon resonance, the  
phase-lock-loop circuit, which controls the cell driver circuit, maintains the resonance at the detected (or sensed)  
frequency.

The resonance of the water capacitor cell is affected by the volume of water in the cell. The resonance of any  
given volume of water contained in the water capacitor cell is also affected by “contaminants” in the water which  
act as a damper. For example, with a potential difference of 2,000 to 5,000 volts applied to the cell, a current  
spike or surge may be caused by inconsistencies in the water characteristics which cause an out-of-resonance  
condition which is remedied instantaneously by the control circuits.

In the invention, the adjustable frequency generator, shown in Fig.12, tunes in to the resonant condition of the  
circuit which includes the water cell and the water inside it. The generator has a frequency capability of 0 to 10  
KHz and tunes into resonance typically at a frequency of 5 KHz in a typical 3-inch long water capacitor formed  
from a 0.5 inch rod inside a 0.75 inch inside-diameter cylinder. At start up, in this example, current draw through  
the water cell will measure about 25 milliamps; however, when the circuit finds a tuned resonant condition, the  
current drops down to a 1 to 2 milliamp leakage condition.

The voltage to the capacitor water cell increases according to the turns of the winding and the size of the coils, as  
in a typical transformer circuit. For example, if 12 volts is sent to the primary coil of the pulsing core and the  
secondary coil resonant charging choke ratio is 30 to 1, then 360 volts is sent to the capacitor water cell. The  
number of turns is a design variable which controls the voltage of the unipolar pulses sent to the capacitor.

The high-speed switching diode, shown in Fig.10, prevents charge leaking from the charged water in the water  
capacitor cavity, and the water capacitor as an overall capacitor circuit element, i.e. the pulse and charge status of  
the water/capacitor never pass through an arbitrary ground. the pulse to the water capacitor is always unipolar.  
The water capacitor is electrically isolated from the control, input and driver circuits by the electromagnetic  
coupling through the core. The switching diode in the Voltage Intensifier Circuit (Fig.10) performs several  
functions in the pulsing. The diode is an electronic switch which determines the generation and collapse of an  
electromagnetic field to permit the resonant charging choke(s) to double the applied frequency and it also allows  
the pulse to be sent to the resonant cavity without discharging the “capacitor” therein. The diode is, of course,

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S01603)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/1603) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
