REJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITY

science · SOURCE BATCH2-006

A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

Open first-party PDF viewer

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

Contents and coverage · All reading editions · Explanatory guides · Source metadata

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Full commentary and investigation questions

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 1532 · section 1613/1965 · approximately 4 minutes

A - 686

A - 686
The MLS-HFS shown in Fig.1, is a hydroxyl gas and heat generating system which uses a renewable source of
liquid supply 30 such as water. It uses a computer control program 75 with display interface 95, for the
monitoring, adjusting and controlling of the electronic and hardware apparatus and process logic. The electronic
circuits 102 mounted in driver 100, control the production of the gases and heating while circuit 105 controls the
process and routeing of the hydroxyl gas.

The system consists of a low-pressure hydrolyser cell 120 in Fig.1, a liquid trap 130, an adjustable flow-restriction
valve 135, high-pressure vacuum pump 140, and check valve 142 installed in 140. It also contains a high-
pressure storage tank 150, an alarm/low-pressure cut-off valve 165, gas regulator 160, flashback arrestor 170,
over-pressure safety release valves 125, pressure gauges 128, analogue pressure-sending units 122 installed on
cell 120, and tank 150 at the regulating side of regulator 160. Also, 125 is installed on Compressor 140 high-
pressure output. The computer controller 70, monitor 90, keyboard 80, interface I/O card 72 and software position
pointer 85, are used to control the production process, using electronic driver 100 through it’s PC boards 105 and
their attached control devices. The power to the cell-driving circuits 102, installed in driver 100, is supplied from a
dual three-phase isolated power source 110. The amplitude, signal phases and frequency from this power source
is controlled by signal adjustments coming from the computer 70.

Detailed Description

Sequence of Operation
The system shown in Fig.1 is monitored and controlled by the software program 75, computer 70, monitor 90,
keyboard 80, pointer 85, and display interface 95 in Fig.2.

The software program has five main functions, namely: to purge the system of ambient air, check and test for any
equipment malfunctions, prepare the system for production, monitor and control the current activities of the
production process, and the safety shutdown of the system if alarms are detected.

During the initial installation, and again after any repairs, the total system is purged using the vacuum pump 140,
using manual procedures to ensure that all ambient air has been removed from the system. Before the system is
put into service, the operator can test the operation of the system by using the graphic display. The main
functions of the testing is to ensure that the temperature electronics 131 attached to the hydroxyl cells 120,
transferring compressor 140 and analogue pressure sensors 122 mounted on cells 120, high-pressure tank 150
and the discharge side of regulator 160 used for control and monitoring, are working properly. the operator can
then activate the Run Sequence of the program 75 via the start software button 280 in Fig.2 on graphic display
95.

During the initial startup phase of the system, the computer program will configure the system for the purge
sequence. this sequence allows the vacuum pump 140 to draw down the hydroxyl cells 120 liquid trap 130
coupled to flow-restriction valve 135, to remove all ambient air from them. Once the program has done this and
detected no leaks in the system, it then prepares the system for gas production by switching the gas flow from
cells 120 to high-pressure tank 150 and on to the output flashback protector 170.

The program starts it’s production sequence by turning on the cooling system pump 10 which is submerged in the
liquid bath 30, contained in vessel 20. The cooling liquid is pumped through the cooling jacket 50 which is
attached to the outside of cells 120, through filter 45 and then through an air-cooled radiator 60. Fans attached to
the radiator are turned on for cooling.

Next, the computer turns on the dual three-phase power source 110, which supplies operating power to the
frequency, phase-shifting, signal amplitude and impedance-matching circuits coupled to the hydroxyl generating
cells.

The result of this is just like the operation of a radio transmitter matching it’s signal to the air via the antenna
impedance. Fig.3 shows the relationship of this configuration to arrays 132, water bath 133 and Signals (Fig.5
and Fig.6).

While the power source 110 is operating, the computer 70 is monitoring the pressure 122 and temperature 131 of
hydroxyl cells 120. When the cell pressure reaches a typical level of 5 pounds per square inch, the power source
is turned off and compressor 140 is turned on the pump the gas into pressure tank 150. When the pressure in the
hydroxyl cells 120 is drawn down to near zero, the compressor is turned off and the power to the gas generating
cells is turned back on again, to repeat the cycle.

This full section as JSON

Congratulations. You’ve won a support ticket.

Your prize is an email address. No purchase required—but coffee helps keep this place online.

Open a support ticket: azmin@zedec.ai

Support and privacy requests are free. Response times are not guaranteed.

The ceremonial small print

“Due to unusual call volume and support volume, we are experiencing longer than normal wait times for a response.” This is our satirical holding message, not a measured queue report. We offer email support.

America runs on coffee, Britain puts the kettle on, and the opium trade reminds us that empires have had considerably worse business plans.

Donation is optional. No prize draw, purchase verification or guaranteed response is involved. Mandatory legal response duties still apply.

Public-interest research, not a spy drop. We keep 18 U.S.C. § 793 on the reading list—and restricted material off the guest list.

Site support and inquiries are welcome: azmin@zedec.ai. We reserve the right to remain silent, subject to legally required responses.