---
canonical: "https://yogababe.online/reading/BATCH2-006/167"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 167 · 5 - 22 | Rejuvenati"
content_sha256: "621cdc6a1bcc9571623a811cbf155289eab001ec9a6315e575a8735d5c9d7af3"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 165 · section 167/1965 · approximately 4 minutes

## 5 - 22

5 - 22  
Fig.2 is a horizontal central cross-section of Fig.1

Fig.3 is a diagram of the circuits of the entire system, the generator being shown in section.

I use a core, A, which is closed upon itself – that is to say, of an annular cylindrical or equivalent form – and  
as the efficiency of the apparatus is largely increased by the subdivision of this core, I make it of thin strips,  
plates or wires of soft iron, electrically insulated as far as is practicable. On this core, using any well-known  
method, I wind, say, four coils, B B B’ B’, which I use as primary coils, and for which I use long lengths of  
comparatively fine wire. Over these coils I then wind shorter coils of coarser wire, C C C’ C’, to constitute  
the induced or secondary coils. The construction of this or any equivalent form of converter may be carried  
further, as pointed out above, by enclosing these coils with iron – as, for example, by winding a layer or  
layers of insulated wire over the coils.

The device is provided with suitable binding-posts, to which the ends of the coils are led. The diametrically-  
opposite coils B B and B’ B’ are each connected in series and terminated on the binding-posts 1, 2, 3 and 4.  
The induced coils are connected together in any desired manner. For example, as shown in Fig.3, C C may  
be connected in multiple arc when a quantity current is desired – as for running a group of incandescent  
lamps, D – while C’ C’ may be independently connected in series in a circuit including arc lamps or the like.  
The generator in this system will be adapted to the converter in the manner illustrated. For example, in the  
present case, I use a pair of ordinary permanent or electro magnets, E E, between which is mounted a  
cylindrical armature on a shaft, F, and wound with two coils G and G’. The terminals of these coils are  
connected, respectively, to four insulated contact or collecting rings, H H H’ H’, and the four line circuit-wires  
L connect the brushes K, bearing on these rings, to the converter in the order shown.

Noting the results of this combination, it will be observed that at a given point of time, the coil G is in its  
neutral position and is generating little or no current, while the other coil, G’, is in a position where it exerts  
its maximum effect. Assuming coil G to be connected in circuit with coils B B of the converter, and coil G’  
with coils B’ B’, it is evident that the poles of the ring A will be determined by coils B’ B’ alone; but as the  
armature of the generator revolves, coil G develops more current and coil G’ less, until G reaches its  
maximum and G’ its neutral position. The obvious result will be to shift the poles of the ring A through one  
quarter of its periphery. The movement of the coils through the next quarter of a turn, during which coil G’  
enters a field of opposite polarity and generates a current of opposite direction and increasing strength, while  
coil G, in passing from its maximum to its neutral position, generates a current of decreasing strength and  
same direction as before, causes a further shifting of the poles through the second quarter of the ring. The  
second half-revolution will obviously be a repetition of the same action. By the shifting of the poles of the  
ring A, a powerful dynamic inductive effect on the coils C C’ is produced.

Besides the currents generated in the secondary coils by dynamo-magnetic induction, other currents will be  
set up in the same coils in consequence of any variations in the poles of the ring A. This should be avoided  
by maintaining the intensity of the poles constant, to accomplish which, care should be taken in designing  
and proportioning the generator and in distributing the coils in the ring A and balancing their effects. When

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S00167)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/167) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
