---
canonical: "https://yogababe.online/reading/BATCH2-006/1701"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 1701 · A - 776 | Rejuvenati"
content_sha256: "a1dc5272ceec28d2bba70461bc4165ed54726bc60c59381dc91c8e03946090ff"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 1622 · section 1701/1965 · approximately 5 minutes

## A - 776

A - 776  
Ultrasonic cavitations in liquid (sonic-technology) will enhance the plasma formation and the catalytic reactions  
that benefit a number of under-liquid plasma applications.

The under-liquid plasma requires an input of DC or AC voltage in the range from 350V up to 3000V and current  
density ranging from 1 Amp to 3 Amp per cm2 in dealing with a large range of liquid media. The specific voltage  
and current requirement for a given application depends very much on the chemical and physical properties of  
electrolytic liquid as well as those factors mentioned above.

The under-liquid plasma method according to the current invention, can operate at atmospheric pressure and  
ambient temperature. However, an external pressure less than one atmosphere or over one atmosphere with  
higher temperatures does not deter the generation of plasma in the bubbles. A higher temperature in the liquid  
also means more active gas molecules within the bubbles, which can benefit plasma formation.

Non-thermal plasma generated in a liquid according to the present invention, has advantages over known types of  
plasma discharge, for example in gas, under water plasma arc and pulse power electric discharge, these being:

It requires only simple electrolytic cells to be the reactor to perform such discharge. There is little erosion to  
the electrodes and wider range of electrode materials can be chosen such as stainless steel, graphite,  
aluminium and good conductive materials which are resistance to chemical erosion. The polarity of the  
electrode can be reverted if necessary to compensate the lost of electrode materials if so desired.

It works under one atmospheric pressure and ambient temperature. The liquid electrolyte will be primary  
source of materials for the chemical and physical reaction take part in the process. There are number of ways  
that bubbles can be produced within the electrolytic cell. Gas can also be introduced to the reactor where  
plasma catalytic and dissociation is taking place.

It is a low-temperature system as the plasma discharge is non-thermal. Any excessive or undesirable high  
temperature can be lowered by increasing the circulation rate of the liquid which can lose its temperature  
through heat exchange. Heat generated can be recovered as secondary energy.

The electrolyte (liquid) will serve as extension of the conducting electrodes in contact with the gases or vapour  
trapped inside the bubbles. The air gap between two electrodes is reduced to the thickness of the gas bubbles or  
air pocket which thus enables plasma discharge at a much lower voltage and current compared with other plasma  
discharge systems. Plasma glow discharge, according to the present invention, can be initiated under conditions  
of a voltage as low as 350V and the current ranging from 50 mA to 800 mA. Extra energy is not required in  
splitting the water molecules to transient bubbles as in the other underwater electrical discharge system which  
requires voltage not less than 5 to 6 KV, and very high current over 200 A in pulsed supply. Plasma discharge will  
also take place in gas pockets or bubbles away from the electrode as long as the electric field strength is sufficient  
to cause such discharge.

The electrolyte also serves as a confinement of gas generated within the system, or purposely introduced gas of  
known properties, instead of ordinary air which may lead to production of unwanted NOx for example. Noble gas  
such as argon is not necessary to enhance the initiation of glow discharge sometime required in the air discharge  
system.

The electrolyte also serves as a conductor and passage for the transportation of ionised species and transmission  
of electrons. The ionised atoms and molecules deriving from the electrolyte will be collected in their respective  
electrodes in the form of gas or material deposit. These ionised species are either serving as a reduction or  
oxidation agent in their respective half-cell. Since the gas ions produced during the discharge migrate to their  
respective poles to be collected individually, hydrogen gas and oxygen gas can be collected separately.

The gas and vapour molecules and atoms inside the bubble which undergo plasma glow discharge are ionised,  
excited or dissociated to produce the very active species for reduction, oxidation, and the forming of neutral or  
radical species which in turn react with the chemical elements present in the gas and liquid interface aligning  
bubbles wall. The large number of bubbles generated near the electrodes and in the nearby liquid, come into  
contact with a much larger volume of liquid nad so provides effective treatment, breakdown, transformation of  
chemicals, organic matter or elements which have been targeted.

Liquid is a good medium for transmitting ultrasonic waves. Sonic-excitation is beneficial for the dissociation of  
materials and extermination of microbes and it aids the breakdown and local melting of colloidal solids during  
impact which also enhances the plasma oxide reduction process. The generated ultrasonic cavitations may be  
fully utilised to work in conjunction with the under-liquid plasma discharge. An ultrasonic cavity is micro in size  
and uniformly distributed in the entire liquid volume. The cavities are a high vacuum which contain liquid vapour  
and gas, and these favour plasma discharge. The high temperature and pressure reaching 10,000OK and a

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S01701)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/1701) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
