Source page 1641 · section 1721/1965 · approximately 4 minutes
A - 795
A - 795
The gas trap or chamber should be of a suitable size. If the gas trap or chamber is too big, then the trapped gas
is too thick which requires a much higher voltage for discharge breakdown and prolongs the time of each cycle of
discharge. It becomes difficult to maintain rapid cyclical steady glow discharge. The perforated covering plate, is
also an important part of the electrode structure, concentrating the current density. The thickness of the
perforated plate and the size of the gas trapping chamber should be carefully controlled so that the electrode
spacing gap is not unduly wide as that also influences the voltage requirement. The size and disposition of
perforated holes can be determined by trial and error. Wide electrode spacing increase the voltage input
requirement and unsuitably close electrode spacing will cause early occurrence of plasma arcing with high current
surge and generation of temperatures which will damage the electrodes and their attachments.
The power unit should be of adequate power rating. The electric breakdown is highly dependent on the high
voltage supply. If the rating of the power supply unit is inadequate, it could easily be damaged during sudden the
high current surge caused at cyclical electric breakdown. There will be no plasma discharge if the power input is
inadequate.
The electrolytic liquid should have suitable conductivity, not too low nor too high. Voltage cannot be easily raised
between two electrodes the liquid has high conductivity and no plasma discharge will be generated unless there is
a high voltage input. The discharging electrode may be fully encapsulated inside a bubble barrier, but high
conductivity liquid allows the current to pass through the bubble-liquid interface which in turn, also prevents the
voltage rising high enough. If the conductivity of the liquid is too low, then the bubble barrier forms a complete
dielectric barrier which requires a much higher inception voltage to cause electric breakdown or discharge and at
the same time, the passage of current becomes too low which results in a low current density which also
influences the occurrence of discharge. A much higher breakdown voltage (discharging voltage) creates electric
arcing in gaseous condition which is no longer considered non-thermal under-liquid plasma discharge.
CONCLUSIONS
1. Gas layer or bubbles form the dielectric barrier that provide the environment for building up the discharge
voltage and gaseous space for plasma discharge to take place. High voltage and relatively low current input is
characteristic of under-liquid plasma.
2. With the characteristic high voltage and low current requirement, the under-liquid plasma can be generated
over a wide range of liquids. The electrolyte liquid can be acidic, alkaline or a solution of salts. Liquids containing
conducting impurities or a mixture of organic compounds may also serve as electrolyte such as the case of tape
water and fruit drinks.
3. There are a number of factors which would affect the generating of under-liquid plasma such as voltage,
current density, configuration of electrodes, area of electrode surface, electrode gap spacing, electrolytic physical
and chemical properties, gas retaining and trapping arrangement, provision of plasma enhancement, ultrasonic
cavitations, pulsed power supply, ambient temperature and reactor construction. This appears complicated, but
the experiments undertaken have demonstrated that all the mentioned factors can be manipulated to achieve
generation of stable non-thermal plasma at one atmosphere of pressure.
4. Plasma is the fourth state of matter. It has been widely employed in the field of chemical, electronic, materials
and energy industries. Plasma generated under-liquid plasma has its own intrinsic characteristics and
advantages, which have already proved to be a useful tool for plasma electroplating or deposition of both metallic
and non-metallic materials. It will find its application in the plasma-assisted water electrolysis for hydrogen
production; reformation of hydrogen rich compounds or hydrocarbon fuel (gas and liquid); decontamination of both
liquid and gas pollution discharges containing persistent harmful chemicals, dissolved heavy metals and organic
and biological contaminants; sterilisation of fruit drinks, potable water supply; and reduction of material oxide such
as oxide ores, metal oxide as an alternative method metal refinement. It is probable that the proposed under-
liquid plasma generation, and this established basic scientific information, would form the basis for further
refinements leading to the practical new applications put forward in this patent application.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.