Source page 1643 · section 1723/1965 · approximately 5 minutes
A - 797
A - 797
space either in the metal electrode or in the covering materials, capable of retaining gas while at the same time
having the mechanism to concentrate the current density to a localised discharge point. This leads to a wide
variety of designs and choice of materials to satisfy plasma discharge requirement.
In order to avoid recombination of H+ and H2 with OH ions and reverting back to water, the hydrogen atoms after
regaining their lost electrons through contacting the cathode should be allowed to escape quickly from the area
which abounds with other oxidation species and radicals. This has greatly influenced the productivity of hydrogen
gas. If H+ and OH is allowed to recombined, despite of the apparent bubble boiling in the reactor very little gas
can be collected and the temperature in the reactor rises quickly which could well be the exothermic effect of
recombination of H+ and OH.
The hydrogen produced is collected separately from the oxygen. Since the produced hydrogen gas contains a
fair amount of water vapour, the hydrogen gas is collected by passing it through a water chiller or other known
method, so that the measured gas volume is at room temperature with minimum water vapour content.
The basic plasma assisted electrolysis cell or reactor can be produced in modular form which can be mounted
side by side and placed inside a single electrolytic tank with their respective power and output gas collected to
form a major production unit. Several reactor types can be employed for the production of hydrogen. Rod or wire
in tube reactor, tube in tube reactor, single or multiple cell reactors are also suitable for the plasma assisted water
electrolysis. The gas retaining and current concentrating cover will be affixed on the cathode electrode facing the
anode electrode. A horizontal reactor whose cathode has a gas-retaining cover can be placed on top of an anode
which is separated by a diaphragm and the hydrogen gas will then collect in isolation.
The introduction of ultrasonic cavitations into the electrolytic liquid is easy since the electrolysis bath is also the
ultrasonic bath and ultrasonic transducers can be attached to the bath externally. A mixture of sonic frequency
should be used to avoid any occurrence of a dead sonic zone. The introduction of sonic excitation through
cavitations enhances the production performance of plasma-assisted electrolysis.
Pulsed high-voltage DC supply with single polarity square wave from 5 KHz up to 100 KHz has been found to be
beneficial for generating plasma at a much reduced voltage.
The distinct advantage of the under-liquid plasma enables ionised species migrate to the respective half cell and
electrodes which will avoid and minimise re-mixing of the produced hydrogen and oxygen causing a reversion to
water again and creating a hazardous, explosive condition. The oxygen is considered as a by- product which can
be collected for use or it can be channelled to the combustion chamber if hydrogen is used as direct fuel for a
combustion engine.
Water is the primary source material for hydrogen production, being economically available and of unlimited
supply. It is a completely clean source material that produces no unwanted by-products.
The anode may be gradually losing its materials due to electro transportation, but if so, it will be a very slow
process. In practice the polarity of electrodes can be reversed which reverses the materials transportation and
deposition. Conductor materials which are inert to electro-chemical corrosion are a good choice to serve as
electrodes.
A chemically conductive reagent may be added to water to increase its conductivity and a foaming agent added to
enhance generation of bubbles. The electrolyte can be of acidic or alkaline base. The concentration of the
electrolyte should be maintained at a steady level for best results. High electrolyte concentration increases liquid
conductivity as well as productivity of gas bubbles but it might prevent the rising voltage required for discharge as
the current flow between electrode will not be inhibited by the presence of bubbles. However, a very low
concentration of electrolyte will favour dielectric breakdown of bubbles, as a lesser current will be carried by the
liquid medium inbetween the bubbles. It has been found that either acidic or alkaline electrolyte with 0.02%
concentration work extremely well in maintaining steady glow discharge with DC voltage ranging from 350 V to
1,800 V and a current from 100 mA to 800 mA.
Tap water has been used without adding any conducting reagent and it often works unexpected well, most likely
due to present of impurity and high pH, in the plasma-assisted electrolysis where steady glow discharge occurs at
around 450 V to 900 V and current around 200 mA to 350 mA. The power input requirement varies in
accordance to electrode spacing, electrode and reactor configuration, electrolyte concentration and the structure
of gas retaining arrangement. Again other plasma assisted method such as pulsed power input and ultrasonic
cavitations etc. also help to lower the power input requirement.
The process is in general, conducted at one atmosphere pressure. An increase of pressure will slow down
upward movement of the bubbles and raise the temperature of the electrolyte. Some increase in temperature in
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.