Skip to contentREJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITYTranslated introduction guidesTranslate this page without leaving it. First-time translations use the owner's local computer and are then cached for everyone; uncached translations may be unavailable while that helper is offline. Automatic translation may contain errors. Scientific identifiers and numeric data stay unchanged. Verify medical information against the original source.
science · SOURCE BATCH2-006
A Practical Guide to Free-Energy Devices — Patrick J. Kelly
attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.
Source page 1829 · section 1917/1965 · approximately 2 minutes
A - 983
A - 983
Fig.5 shows the state of the switch assembly when rotor shaft 10 has rotated approximately 180 degrees from the position shown in Fig.4. When the switch assembly is in the state shown in Fig.5, D.C. power supply 64 has its positive and negative terminals connected electrically by contact fingers 66 and 68 to contact plates 59 and 60, respectively. Contact finger 70, shown contacting plate 60, connects terminal 72 of solenoid 74 electrically to the negative terminal of the power supply 64 through contact finger 68 and contact plate 60. Contact finger 80, shown contacting plate 59, connects terminal 78 of solenoid 74 electrically to the positive terminal through contact finger 66 and contact plate 59. Contact finger 76, axially aligned with contact plate 62 and offset axially from contact plate 60, remains connected to terminal 78 of solenoid 74. In this way, the polarity of the solenoid 74 changes cyclically as the rotor 10 rotates through each one-half revolution.
Fig.6 shows in cross-section, the cylinder 58 which is aligned with and driven by the rotor shaft 10, a contact finger 70, and the contact plates 59 – 62 of the switching assembly, which rotate with the rotor shaft and cylinder about the axis 11 .
As Fig.7 illustrates, axially spaced arms 82 are supported on a stub shaft 71, preferably made of Teflon or another self-lubricating material, to facilitate the pivoting of the arms about the axis of the shaft 71. Each contact finger 66, 68, 70, 76 and 80 is located at the end of a arm 82, and tension springs 84, secured to each arm 82, urge the contact fingers 66, 68, 70, 76 and 80 continually toward engagement with the contact plates 59 – 62.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.