Skip to contentREJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITYTranslated introduction guidesTranslate this page without leaving it. First-time translations use the owner's local computer and are then cached for everyone; uncached translations may be unavailable while that helper is offline. Automatic translation may contain errors. Scientific identifiers and numeric data stay unchanged. Verify medical information against the original source.
science · SOURCE BATCH2-006
A Practical Guide to Free-Energy Devices — Patrick J. Kelly
attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.
Source page 1860 · section 1950/1965 · approximately 2 minutes
A - 1014
A - 1014
Fig.20 is similar to Fig.19 except that a second permanent magnet 214 is positioned at a location spaced above the air coil 210. In Fig.20 no voltage is applied across the air coil 210 and therefore the air coil 210 does not have an electro-magnetic field. Thus Fig.20 shows only the combined affect of the fields of the permanent magnets 212 and 214. Since the permanent magnets 212 and 214 are positioned so that their respective north and south poles are close together, there will be a strong attractive force between them at the location of the air coil 210.
Fig.21 is a view similar Fig.20 but with an electric potential applied across the air coil 210 and with the upper permanent magnet 214 displaced to the left relative to its position in Fig.20. Note that in Fig.21 the shape of the electro-magnetic field of the air coil 210 is concentrated and shifted somewhat to the right and upward. This shift of the electro-magnetic field concentrates the magnetic coupling between the magnets 212 and 214 to the left thereby increasing the tendency of the upper permanent magnet 214 to move to the left. A much smaller magnetic coupling occurs between the right end of the permanent magnets 212 and 214 and thus the force tending to move the permanent magnet 214 to the right is much less than the force tending to move it to the left. This is illustrated by the size of the arrows shown in Fig.21.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.