REJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITY

science · SOURCE BATCH2-006

A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

Open first-party PDF viewer

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

Contents and coverage · All reading editions · Explanatory guides · Source metadata

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Full commentary and investigation questions

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 193 · section 197/1965 · approximately 3 minutes

6 - 1

6 - 1
A Practical Guide to Free-Energy Devices Author: Patrick J. Kelly
Chapter 6: Pulse-Charging Battery Systems

It is possible to draw substantial amounts of energy from the local environment and use that energy to
charge batteries. Not only that, but when this method of charging is used, the batteries gradually get
conditioned to this form of non-conventional energy and their capacity for doing work increases. In addition,
about 50% of vehicle batteries abandoned as being incapable of holding their charge any longer, will
respond to this type of charging and revive fully. This means that a battery bank can be created for almost
no cost.

However, while this economic angle is very attractive, the practical aspect of using batteries for any
significant home application is just not practical. Firstly, lead-acid batteries tend to get acid all over the place
when repeatedly charged, and this is not suited to most home locations. Secondly, it is recommended that
batteries are not discharged more rapidly than a twenty hour period. This means that a battery rated at a
capacity of 80 Amp-hours (AHr) should not be required to supply a current of more than 4 amps. This is a
devastating restriction which pushes battery operation into the non-practical category, except for very minor
loads like lights, TVs, DVD recorders and similar equipment with minimal power requirements.

The main costs of running a home are those of heating/cooling the premises and operating equipment like a
washing machine. These items have a minimum load capacity of just over 2 kW. It makes no difference to
the power requirement if you use a 12-volt, 24-volt or 48-volt battery bank. No matter which arrangement is
chosen, the number of batteries needed to provide any given power requirement is the same. The higher
voltage banks can have smaller diameter wiring as the current is lower, but the power requirement remains
the same.

So, to provide a 2 kW load with power, requires a total current from 12-volt batteries of 2000 / 12 = 167
amps. Using 80 AHr batteries this is 42 batteries. Unfortunately, the charging circuits described below, will
not charge a battery which is powering a load. This means that for a requirement like heating, which is a day
and night requirement, there needs to be two of these battery banks, which takes us to 84 batteries. This is
only for a minimal 2 kW loading, which means that if this is being used for heating, it is not possible to
operate the washing machine unless the heating is turned off. So, allowing for some extra loading like this,
the battery count reaches, perhaps, 126. Ignoring the cost, and assuming that you can find some way to get
over the acid problem, the sheer physical volume of this number of batteries is just not realistic for domestic
installation and use. In passing, you would also need two inverters with a 2.5 kW operating capacity

This brings home the value of devices like the Wang Shum Ho 5 kW permanent magnet motor-generator
which is compact and requires no fuel or batteries to operate. However, the pulsed-charging systems are
important as they show us features of the local energy field and how to tap it.

John Bedini has designed a whole series of pulse-generator circuits, all based on the 1:1 multi-strand
choke coil component disclosed in his patent US 6,545,444

This full section as JSON

Congratulations. You’ve won a support ticket.

Your prize is an email address. No purchase required—but coffee helps keep this place online.

Open a support ticket: azmin@zedec.ai

Support and privacy requests are free. Response times are not guaranteed.

The ceremonial small print

“Due to unusual call volume and support volume, we are experiencing longer than normal wait times for a response.” This is our satirical holding message, not a measured queue report. We offer email support.

America runs on coffee, Britain puts the kettle on, and the opium trade reminds us that empires have had considerably worse business plans.

Donation is optional. No prize draw, purchase verification or guaranteed response is involved. Mandatory legal response duties still apply.

Public-interest research, not a spy drop. We keep 18 U.S.C. § 793 on the reading list—and restricted material off the guest list.

Site support and inquiries are welcome: azmin@zedec.ai. We reserve the right to remain silent, subject to legally required responses.