Source page 306 · section 310/1965 · approximately 3 minutes
8 - 80
8 - 80
pulses to the cylinders. Distributor 99 has two wipers 99A and 99B and supplies three pulses to each
cylinder per cycle. Wipers 99A and 99B are 180 degrees out of phase with each other and each operates
to supply pulses to its respective cylinder from TDC to 120 degrees thereafter. More pulses are desirable
and therefore a better distributor arrangement (shown in Fig.14) may be used. The arrangement shown in
Fig.14 includes two ignition coils 101, 103, a simple distributor 105 and a pair of magnetic ignition circuits
107 and 109, described below. Of course many other ignition systems could also be developed. For
example, a single circuit might be used in place of circuits 107, 109, additional induction coils might be
added to the ignition coils to assist in starting or a resistor could be added to the ignition coils to ensure a
constant 40,000 volt output regardless of engine rpm. Also, a solid-state distributor could be used instead of
the mechanical distributor labelled 99.
Referring back to Fig.13A, for engines of more than 1000 hp a high frequency source 95 could be used to
control engine RPM. The output frequency is controlled by a foot pedal similar to an accelerator pedal in a
conventional vehicle. The output frequency varies through a range of from approximately 2.057 MHz to
approximately 27.120 MHz with an output current of approximately 8.4 amps. The speed of engine 11 is
controlled by the output frequency of source 95. The high frequency current, as described below, is directed
to each cylinder in turn by circuitry described below. For engines producing from 300 to 1000 hp (not
shown), a high frequency source having a constant output of 27.120 MHz with a constant current of 3.4
amps which is continually supplied to all cylinders could be used. In this case an autotransformer, such as
that sold under the trade designation Variac by the General Radio Company, controlled by a foot pedal
varies the voltage to each cylinder from 5 to 24 volts DC at 4.5 amps, using power from the batteries or the
alternator. The DC current from the Variac is switched from cylinder to cylinder by two small electronic
switching units which in turn are controlled by larger electronic switching units. For the smallest engines (not
shown), a high frequency generator could supply a constant output of 27.120 MHz with a constant current of
4.2 amps to the cylinders during starting only. Speed control would be achieved by a Variac as described
above which controls the DC voltage supplied to the cylinders in turn within a range of from 5 to 24 volts at a
current of 5.2 amps. In this case, once the engine is running, the full voltage needed to ignite the (smaller)
quantity of gases is obtained from the electrodes in the other cylinder of the pair.
The circuitry of Fig.13A also includes the generator, a voltage regulator and relay 111, five electronic
switching units 113, 115, 117, 119 and 121, electrodes 63 and 65 associated with chamber 41A (hereinafter
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.