---
canonical: "https://yogababe.online/reading/BATCH2-006/322"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 322 · 8 - 88 | Rejuvenati"
content_sha256: "2edc398002a10548ce0e5e37d7bc998cdd47f5b402b4a1357c4d8ea3f0ff0acd"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 314 · section 322/1965 · approximately 4 minutes

## 8 - 88

8 - 88

Also shown on Fig.20D is spark chamber 251. Spark chamber 251 includes a small amount of thorium,  
indicated at 377, and a plurality of parallel brass plates 379. When the gases in the mixer reach the proper  
ionisation, the alpha particles emitted by the thorium shown up as flashes of light in the spark chamber.

Turning now to Fig.20B, ionising and filtering unit 215 includes a pair of conductive supports 381 for a  
plurality of conductors 383, said supports and conductors being connected to a voltage source, an insulating  
support 385 for additional conductors 387, and a ZnS screen 388 which emits light when impurities are  
removed from the gaseous fuel mixture. Unit 215 also includes a second set of interleaved conductors  
indicated generally at 389, a cold-cathode tube 391, and an x-ray tube indicated generally at 393. Also  
shown on Fig.20B is an RLC network 395 which has an output on a line 397 which is at 35 V, this voltage  
being supplied to the x-ray tube.

High frequency discharge tube 255 (see Fig.20C) has a conductive electrode 399 at one end to which high  
frequency current is applied to excite the gases in the mixer, and an electrode/heater arrangement 401 at  
the other, a voltage of 45 V being applied to an input 402 of the tube. It is desirable that a small quantity of  
mercury, indicated at 403, be included in tube 225 to promote discharge of the helium gas. Magnetic coils  
237 have disposed therein a pair of generally parallel conductors 405 to which a high frequency signal is  
applied. When gas flows through coils 237 and between parallel conductors 405, therefore, it is subjected  
to the combination of a DC magnetic field from the coil and high frequency waves from the conductors,  
which conductors act as transmitting antennas. The resulting high frequency magnetic field causes the  
atoms to become unstable, which allows the engine to change a given atom's quantum level with much less  
input power than would normally be required. The volume of each gas atom will also be smaller. Also  
shown on Fig.20C is non-directed cathode ray tube 227. The grids of tube 227 are at 145 V, the control  
electrode is at ground, while the anode is at 35 V to 80 V (peak-to-peak). The purpose of non-directed  
cathode ray tube 227 is to add photons to the gas mixture. To generate these photons, tube 227 has a two  
layer ZnS coating indicated generally at 407. Chamber 261, described above, is also shown schematically  
on Fig.20C, along with an RLC network 409.

The power supply for the mixer (see the lower halves of Fig.20E and Fig.20F) also includes two pentodes  
411 and 413, a transformer 415, and a diode tube 417. The control electrode of pentode 411 is at 5 V to 40  
V (peak-to-peak), the grids are at 145 V, the anode is at 100 V, and the cathode is at 8 V to 30 V (peak-to-  
peak). The control electrode of pentode 413 is at 115 V, while its grids and cathode are at -33 V. The anode  
of tube 413 is connected to transformer 415. Also shown on Fig.20E are a relay 419 associated with ion  
gauge 255, and focused x-ray tube 263 associated with ionisation head 240. The upper input to tube 263 is  
at 45 V to 80 V (peak-to-peak).

Turning to Fig.20F, there is shown tubes 265 and 285. Directed cathode ray tube 265 is a pentode  
connected like tube 227. High frequency discharge tube 285 includes a phosphor screen and is connected  
to a high frequency source. Also shown on Fig.20F is a triode 421 with its anode at 30 V, its cathode at  
ground, and its control grid at -60 V; a pentode 423 with its anode at 135 V to 1000 V peak to peak, its  
cathode at ground, its control electrode at 143 V, its grids at 20 V; and a transformer 425. It should be  
understood that various arrangements of electrical components other than those described above could be  
designed to perform the same functions.

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S00322)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/322) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
