---
canonical: "https://yogababe.online/reading/BATCH2-006/326"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 326 · 8 - 90 | Rejuvenati"
content_sha256: "ce3da5b5109365afe10f06a5e585a1bb871b7398a9342ec1a55c2d2ccae1ed31"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 316 · section 326/1965 · approximately 5 minutes

## 8 - 90

8 - 90  
grid of the ionisation gauge. Because the gases are under a partial vacuum, the ionisation gauge is able to  
adjust the gas percentages very precisely. (Note: The steps described in the last two paragraphs are  
repeated if the finished gases are rejected in the final quality control step described below).

The next step involves purifying the mixture so that only the five inert gases remain, absorbing any free  
electrons and regulating the electrical charge in the mixture. To do this, the circuit consisting of the following  
components is opened: Branch B44, magnetic coil 267, magnetic coil 269, ionisation head 240, branch B29,  
ionisation head 231, branch B24, ionisation head 219, pump 217, branches B15 and B39, magnetic coil 287  
(see Fig.17D) polariser 289, branch B17, ionising and filtering unit 215, branches B16, B42, and B41, x-ray  
tube 263, branch B21, ionisation head 221, branch B23, magnetic coil 266, branch B25, and mixing  
chamber 261. The gases should complete this circuit at least three times.

The last step required to prepare the mixture for bottling is polarisation of the argon. The circuit required to  
do this consists of the following components: mixing chamber 261, branch B44, magnetic coil 267, magnetic  
coil 269, ionisation head 240, cathode ray tube 265, branch B40, tubing coil 257, branches B49 and B30,  
ionisation head 231, branch B24, ionisation head 219, pump 217, branches B15 and B39, twin parallel  
magnetic coil 287 (see Fig.17D), polariser 289, branch B17, ionising and filtering unit 215, branches B16,  
B42 and B20, ionisation head 229, cathode ray tube 227, magnetic coil 237, ionisation head 221, branch  
B23 and magnetic coil 266. This too is repeated at least three times. The key to the polarisation of argon is  
polariser 289 and twin parallel magnetic coil 287 that encircles it. Polariser 289 is a glass bottle which is  
filled with finely powdered soft iron which can be easily magnetised. The filled bottle is, in effect, the iron  
core of the coils. The iron particles align themselves with the magnetic lines of force, which lines radiate  
from the centre toward the north and south poles. The ionised gas mixture is forced through the magnetised  
iron powder by means of pump pressure and vacuum, thereby polarising the argon gas. Filters 293 and 295  
are disposed as shown in order to filter metallic particles out of the gas.

The mixture is now double-checked by means of spark chamber 251 at atmospheric pressure since the  
fusion reaction in the engine is started at one atmosphere. Because the gases in mixing apparatus 201 are  
at a partial vacuum, sufficient gases must be pumped into spark chamber 251 to attain atmospheric  
pressure. To do this valves V33, V36 and V40A are closed and circulating pump 217 pumps the gases in  
the mixing apparatus via branches B15 and B39A, through check valve V39A into spark chamber 251 until  
the vacuum and pressure gauge 242 indicates that the gases within spark chamber 251 are at atmospheric  
pressure. Valve V34 is then closed. The spark chamber is similar to a cloud chamber. Six or more high  
capacity brass capacitor plates are spaced 1/8" to 1/4" apart in the chamber. A small plastic container holds  
the thorium 232. One side of the chamber is equipped with a thick glass window through which sparks in the  
chamber may be observed. A potential is placed on the brass plates in the chamber and the current flowing  
between the plates is measured. If this current exactly corresponds to the ionisation current, the mixture is  
acceptable. A difference of greater than 5% is not acceptable. A lesser difference can be corrected by  
recirculating the gas in the mixer and particularly through ionisation gauge 255 as previously described in the  
circulation step. A second test is then given the gases that pass the first test. A calculated high frequency  
current is gradually imposed on the spark chamber capacitor plates. This excitation causes neutrons to be  
emitted from the thorium 232 which, if the mixture is satisfactory, can be easily seen as a thin thread of light  
in the chamber. If the mixture is not satisfactory, light discharges cannot be seen and the high frequency  
circuit will short out and turn off before the desired frequency is reached.

To bottle the mixture, valve V33 is opened and valves V36 and V40 are closed. During bottling polariser  
289, twin parallel magnetic coil 287, ionisation unit 215 and ion gauge 255 are electrically energised (all  
electrical circuits are previously de-energised) to improve the stability of the mixture. The prepared gases  
are withdrawn from the mixing apparatus via branches B24 and B16, ionisation unit 215, branch B17, filters  
293 and 295, polariser 289, twin parallel magnetic coil 287, branch B39, ion gauge 255, check valve V39A,  
branch B38 and spark chamber 251. If desired, after bottling the mixer may be exhausted by opening valves  
V12, V13, V14, V23, V24, V29, V32, V57 and V59. Of course, one can also automate the fuel preparation  
process to be continuous so that it would never be necessary to exhaust the gas.

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S00326)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/326) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
