REJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITY

science · SOURCE BATCH2-006

A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

Open first-party PDF viewer

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

Contents and coverage · All reading editions · Explanatory guides · Source metadata

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Full commentary and investigation questions

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 426 · section 441/1965 · approximately 5 minutes

10 - 26

10 - 26
same goes for the oxygen atoms. The monatomic variety of hydrogen has four times the energy and about 1% of
it mixed with air, is capable of powering an engine without using any fossil fuel oil at all.

If the liquid in the electrolyser is distilled water, then almost no current will flow and almost no gas will be
produced. If you add two or three drops of battery acid to the water, the current and gas production increase
enormously. Putting acid in the water is a bad idea as it gets used in the process, the acidity of the water keeps
changing, the current keeps changing, the acid attacks the electrodes and unwanted gasses are given off.
Putting salt in the water, or using seawater, has nearly the same effect with poisonous chlorine gas being given
off. Baking soda is also a bad choice as it gives off carbon monoxide which is a seriously toxic gas, it damages
the electrodes and ends up as sodium hydroxide. Instead of using these additives, it is much better to use a
“catalyst” which promotes the electrolysis without actually taking part in the chemical process. The best of these
are Sodium Hydroxide (“Red Devil lye” in the USA, “caustic soda” in the UK) and even better still, Potassium
Hydroxide (“Caustic Potash”).

The process of electrolysis is most unusual. As the voltage applied to the plates is increased, the rate of gas
production increases (no surprise there). But once the voltage reaches 1.24 volts across the electrolyte between
the electrodes, there is no further increase in gas production with increase in voltage. If the electrolysis cell
produces 1 litre of hydroxy gas per hour with 1.24 volts applied to the electrolyte, then it will produce exactly 1 litre
of hydroxy gas per hour with 12 volts applied to the electrolyte. Even though the input power has been increased
nearly 10 times, the gas output remains unchanged. So it is much more effective to keep the voltage across the
electrolyte to 1.24 volts or some value near that. As there is a small voltage drop due to the material from which
the electrodes are made, in practice the voltage per cell is usually set to about 2 volts for the very best electrode
metal which is 316L-grade stainless steel.

The electrolyser shown here produces six times as much gas for exactly the same input power. This is a serious
gain in efficiency. As all of the cells of this electrolyser are identical, each has approximately 2 volts across it
when a 12 volt battery is used. The amount of gas produced depends directly on the amount of current passing
through the cells. As they are “in series” (connected in a chain), the same current passes through all of them. For
any given battery voltage and electrode spacing, the current is controlled by the amount of catalyst added to the
water. The liquid in the electrolyser cells is called the ‘electrolyte’. In practice, there is a distinct advantage in
having a large surface area for each electrode, and a small spacing between the electrodes of about 3 mm or
1/8”. Do not allow the hydroxy gas produced to escape upwards as shown above, unless you are outdoors as it
will collect on the ceiling and form an explosive mix there.

There is a strong tendency for bubbles of gas to remain on the surface of the electrodes and impede the
electrolysis process. If there were enough bubbles on an electrode, it would not actually touch the electrolyte and
electrolysis would stop altogether. Many methods have been used to minimise this problem. The electrode
plates are normally made from 16 gauge 316L-grade stainless steel and it is recommended that there be between
2 and 4 square inches of plate area on every face of every electrode for each amp of current passing through the
cell. Some people place an ultrasonic transducer underneath the plates to vibrate the bubbles off the plate
surfaces. Archie Blue and Charles Garrett made the engine suck its input air through the electrolyser and relied
on the air drawn through the electrolyte to dislodge the bubbles. Pulling air through the electrolyte is a very bad
idea as the air contaminates the electrolyte. Some people use piezo electric crystals attached to the plates to
vibrate the plates and shake the bubbles free, others use magnetic fields, usually from permanent magnets. The
best method is to treat the electrode plates with cross-hatch scouring, an extensive cleansing process and an
extensive conditioning process. After that treatment, a catalytic layer builds up on the electrodes, doubling their
efficiency and bubbles no longer stick to the electrodes but break away immediately without the need for any form
of additional help.

As indicated in the drawing above, you MUST NOT perform electrolysis with the gas escaping freely, unless you
are out of doors with very good ventilation. Hydrogen and especially hydrogen/oxygen mix gasses are HIGHLY
dangerous, easily ignited and can easily injure or kill you. They must be treated with a high degree of respect.

This full section as JSON

Congratulations. You’ve won a support ticket.

Your prize is an email address. No purchase required—but coffee helps keep this place online.

Open a support ticket: azmin@zedec.ai

Support and privacy requests are free. Response times are not guaranteed.

The ceremonial small print

“Due to unusual call volume and support volume, we are experiencing longer than normal wait times for a response.” This is our satirical holding message, not a measured queue report. We offer email support.

America runs on coffee, Britain puts the kettle on, and the opium trade reminds us that empires have had considerably worse business plans.

Donation is optional. No prize draw, purchase verification or guaranteed response is involved. Mandatory legal response duties still apply.

Public-interest research, not a spy drop. We keep 18 U.S.C. § 793 on the reading list—and restricted material off the guest list.

Site support and inquiries are welcome: azmin@zedec.ai. We reserve the right to remain silent, subject to legally required responses.