---
canonical: "https://yogababe.online/reading/BATCH2-006/45"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 45 · 1 - 27 | Rejuvenati"
content_sha256: "5198eb8ec11f39cc55bd64b9add58902230f96bd725fbe8b470f40ed4649e373"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 43 · section 45/1965 · approximately 4 minutes

## 1 - 27

1 - 27

Shown here is the situation when one of the top magnets 54 has rotated to be above one of the coils 26  
which is not yet powered up. The South pole of magnet 54 is attracted to the North pole which is the entire  
upper face of magnet 24 as shown by the three arrows. If a voltage is applied to coil 26, then this magnetic  
coupling is disrupted and altered. If any torque is developed as a result of the coil being powered up, then it  
will be developed to either side of the coil 26. If coil 26 is not powered up, then there will be full attraction  
between magnets 24 and 54 and no rotational force will be produced. You will notice that there are two  
rotating magnets (an even number) and seven coils (an odd number) so when one of the rotor magnets is  
above a coil, then the other isn’t. This staggering of the two positions is essential for generating rotational  
torque.

This diagram shows a piece from both sides of the rotor disc, to explain the operation of the coils. On the left,  
magnet 56 overlaps coil 32 and coil 34. Coil 32 is powered up and this breaks the magnetic link on the left  
hand side of magnet 56. But, coil 34 is not powered up, so the attraction between magnet 56 and the disc  
magnet under the coils remains. Even though this attraction is at a downward angle, it creates a push on the  
rotor, driving it towards the right as shown by the red arrow.

While this is happening, the situation around the other side of the rotor disc, is shown on the right. Here,  
magnet 54 is above coil 36 and that coil is not powered up, so there is no resulting drive in either direction.  
The adjacent coil 38 is also not powered up and so has no effect on the rotation. This method of operation is  
very close to that of the motor design of Robert Adams described in the next chapter. It is important to  
understand that this method of operation is nothing like that of the John Bedini pulsers where the rotation of a  
disc is caused by the electrical pulse applied to a coil. Instead, here, the coil acts as a magnetic shield, being  
provided with the minimum possible power to do its job. The coil is, in effect, a shield which has no moving  
parts, and so is a very clever mechanism for overcoming the tendency for the rotor magnets locking on to the  
stator magnets and preventing rotation.

At any moment, six of the seven coils are inactive, so in effect, just one coil is powered. This is not a major  
current drain. It is important to understand that the power of this motor is provided by the permanent  
magnets pulling towards each other. Each of the two magnets applies a horizontal pull on the rotor every  
seventh of a turn, that is, every 51.1 degrees in the rotation. As the coils are an uneven number, the rotor  
gets a magnetic pull every 25.5 degrees in the rotation, first from one rotor magnet and then from the other  
rotor magnet.

It follows then, that the power of the motor can be increased by adding more magnets. The first step in this  
search for additional power is to add a second disc magnet and coils on the other side of the rotor, so that  
there is a second pull on the magnet. This has the added advantage that it balances the downwards pull of  
the first disc magnet with an upward pull, giving an enhanced and balanced horizontal thrust as shown here:

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S00045)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/45) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
