Source page 447 · section 462/1965 · approximately 2 minutes
10 - 47
10 - 47
To make sure that the locking bolts do not short-circuit the plates, they are fitted with 3/8" (9 mm) outer diameter /
1/4" (6 mm) inner diameter rubber fuel-hose material.
The end plates receive careful preparation. They are first cleaned of mill-scale by being submerged in
hydrochloric acid and connected to a DC power supply. A scrap piece of stainless steel is connected to the DC
minus and the plate to the DC plus. This is, of course, done in a well-ventilated area and while wearing safety
clothing, gloves and goggles. The cleaning process takes only five minutes or so, and then the plate is rinsed off
with clean water. This process produces a good clean plate surface. The pipe fittings which Bill uses are to the
US "National Pipe Thread" ("NPT") thread pitch but your local thread pitch is just as suitable, especially since Bill
opts to weld the fitting to the outside of the plate as shown here:
The recommended end-plate pipe fittings are:
Bottom fittings: 90O male 1/2" NTP to 1/2" male tubing (2 required)
Top fittings: 1/2" NTP male T-piece to 3/8" male tubing, 90O (2 required)
The Tank/Bubbler pipe fittings are:
Bottom, outer fittings: 1/2" NPT male T-piece, to 3/8" male tubing (2 required)
Bottom, centre fitting: 1/2" NPT male to 1/2" male tubing (1 required)
Top, centre fitting (gas outlet): 1/2" NPT to 3/8" male 90O (1 required)
Top, outer fitting (manual refill): 1/2" NTP plug (1 required)
After the pipe fittings have been welded in place, the parts of the plates which can be seen from the outside are
given a protective coat of paint. This paint avoids the area around both ends of one of the clamping bolts as the
electrical connection is made to that bolt and so it has to be in very good electrical connection with both of the end
plates. The electrical arrangement has the two outside plates connected together and the centre plate used as
the other electrical contact. This produces two separate 6-cell boosters, back to back. The simplified version is
arranged like this:
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.