canonical: "https://yogababe.online/reading/BATCH2-006/484"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 484 · 10 - 68 | Rejuvenati"
content_sha256: "1b3d440282bf4e4883bb23fa2e9c44b69e6f9804f17dfe4a56cc7aadab00bd65"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 468 · section 484/1965 · approximately 5 minutes

## 10 - 68

10 - 68  
8\. A crimping tool and some crimp connectors.  
9\. A multimeter (preferably a digital one) with a DC voltage measuring range of 0 to 15 volts or so.  
10\. (Optional) a magnifying glass of x4 or higher magnification (for very close examination of the soldering)

Soldering  
Many electronic components can be damaged by the high temperatures they are subjected to when being  
soldered in place. I personally prefer to use a pair of long-nosed pliers to grip the component leads on the upper  
side of the board while making the solder joint on the underside of the board. The heat running up the component  
lead then gets diverted into the large volume of metal in the pair of pliers and the component is protected from  
excessive heat. On the same principle, I always use an Integrated Circuit socket when soldering a circuit board,  
that way, the heat has dissipated fully before the IC is plugged into the socket. It also has the advantage that the  
IC can be replaced without any difficulty should it become damaged.

If you are using CMOS integrated circuits in any construction, you need to avoid static electricity. Very high levels  
of voltage build up on your clothes through brushing against objects. This voltage is in the thousands of volts  
range. It can supply so little current that it does not bother you and you probably do not notice it. CMOS devices  
operate on such low amounts of current that they can very easily be damaged by your static electricity. Computer  
hardware professionals wear an earthing lead strapped to their wrists when handling CMOS circuitry. There is no  
need for you to go that far. CMOS devices are supplied with their leads embedded in a conducting material.  
Leave them in the material until you are ready to plug them into the circuit and then only hold the plastic body of  
the case and do not touch any of the pins. Once in place in the circuit, the circuit components will prevent the  
build up of static charges on the chip.

Soldering is an easily-acquired skill. Multi-cored solder is used for electronic circuit soldering. This solder wire  
has flux resin contained within it and when melted on a metal surface, the flux removes the oxide layer on the  
metal, allowing a proper electrical and mechanical joint to be made. Consequently, it is important that the solder  
is placed on the joint area and the soldering iron placed on it when it is already in position. If this is done, the flux  
can clean the joint area and the joint will be good. If the solder is placed on the soldering iron and then the iron  
moved to the joint, the flux will have burnt away before the joint area is reached and the resulting joint will not be  
good.

A good solder joint will have a smooth shiny surface and pulling any wire going into the joint will have no effect as  
the wire is now solidly incorporated into the joint. Making a good solder joint takes about half a second and  
certainly not more than one second. You want to remove the soldering iron from the joint before an excessive  
amount of heat is run into the joint. It is recommended that a good mechanical joint be made before soldering  
when connecting a wire to some form of terminal (this is often not possible).

The technique which I use, is to stand the solder up on the workbench and bend the end so that it is sloping  
downwards towards me. The lead of the component to be soldered is placed in the hole in the strip-board and  
gripped just above the board with long-nosed pliers. The board is turned upside down and the left thumb used to  
clamp the board against the pliers. The board and pliers are then moved underneath the solder and positioned so  
that the solder lies on the copper strip, touching the component lead. The right hand is now used to place the  
soldering iron briefly on the solder. This melts the solder on the joint, allowing the flux to clean the area and  
producing a good joint. After the joint is made, the board is still held with the pliers until the joint has cooled down.

Nowadays, the holes in the strip-board are only 1/10 inch (2.5 mm) apart and so the gaps between adjacent  
copper strips is very small indeed. If you solder carefully, there should be no problem. However, I would  
recommend that when the circuit board is completed, that you use a magnifying glass to examine the strip side of  
the board to make quite sure that everything is perfectly ok and that solder does not bridge between the copper  
strips anywhere. Before powering up the circuit, double-check that all of the breaks in the copper strips have  
been made correctly. Here is a possible layout for the components on the strip-board:

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S00484)

---