---
canonical: "https://yogababe.online/reading/BATCH2-006/495"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 495 · 10 - 80 | Rejuvenati"
content_sha256: "ec60e2f48539b25bbee9c02a42eadaa662a0801579f7cd16b616dda7db0c41e2"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 480 · section 495/1965 · approximately 5 minutes

## 10 - 80

10 - 80  
Here, the explosion is almost instantaneous and the explosion attempts to force the piston downwards.  
Unfortunately, the crankshaft is trying to drive the piston upwards past the Top Dead Centre (‘TDC’) point, so the  
explosion will not help the engine run. Instead, the explosion will stop the crankshaft rotating, overload the  
crankshaft and connecting rod and produce excessive pressure on the wall of the cylinder.

We do not want that to happen. The solution is to delay the spark until the piston has reached the position in its  
rotation where we want the explosion to take place - that is, in exactly the same place as it did when using petrol  
as a fuel.

In the example above, the spark would be retarded (delayed) from 8 degrees before TDC to 8 degrees after TDC,  
or 16 degrees overall. The spark is ‘retarded’ because it needs to occur later in the rotation of the crankshaft.  
The amount of retardation may vary from engine to engine, but with hydroxy gas, the spark must never occur  
before TDC and it is preferable that the crankshaft has rotated some degrees past TDC so that most of the push  
from the piston goes to turn the crankshaft and as little as possible in compressing the crankshaft.

Waste Spark  
One obvious application for a device such as this is to power a standard electrical generator and use part of the  
generator’s output to power the electrolyser once the generator gets going. While this looks like a good idea,  
there are some practical issues which need to be dealt with.

Firstly, as detailed above, when running an internal combustion engine on hydroxy gas, it is essential to delay the  
spark until several degrees after Top Dead Centre. This may be difficult or impossible to do on some generators,  
so a careful examination of the engine details should be made before buying the generator. It is much easier to  
choose carefully than to be faced with a difficult timing adjustment on an engine which was never intended to  
have the timing adjusted.

Secondly, it is cheaper for the manufacturer to operate the spark from the output shaft of the engine rather than  
taking a linkage from the camshaft of a four-stroke engine. This generates a spark for every revolution of the  
output shaft. But, a four-stroke engine only needs a spark on every second revolution, so the extra spark is not  
needed and so is called a “waste” spark as it is wasted since there is no gas for it to ignite.

This waste spark is harmless when the engine is being run on fossil fuel which needs a spark timing before Top  
Dead Centre. The waste spark is most definitely not harmless when the timing is altered to some degrees after  
Top Dead Centre as needed by hydroxy gas operation. In this instance, when the waste spark occurs, the intake  
valve will be open creating a continuous path to the bubbler, and the waste spark will ignite the gas. It is  
absolutely vital to suppress any waste spark, and that is seldom an easy thing to do.

The spark timing needs to be mechanically linked to the position of the cam shaft, with either a contact on the cam  
shaft or a valve, or a 2:1 gearing down of the drive shaft as no electronic circuit can distinguish one particular  
pulse from a long row of identical pulses. It is easy to build an electronic circuit to suppress every second spark,  
but there is no way of knowing which spark to suppress. Pick the wrong spark and you instantly blow the gas  
supply. All the sparks look the same so you have a 50% chance of picking the wrong spark to suppress, so a  
contact or sensor on the cam shaft or a valve is essential whether or not an electronic circuit is used. An  
alternative is to take the timing from an external shaft, geared down to half the speed of the drive shaft as that is  
essentially a replication of the cam shaft.

So, when considering what generator to buy, you need to check the electrical power output, the noise level, the  
timing adjustment and if there is a waste spark and how easy it would be to avoid it.

Handling the electrolyte  
This electrolyser design uses potassium hydroxide solution in the electrolyser itself and fresh water in the water  
tank as the potassium hydroxide is a true catalyst which assists the electrolysis process but does not get used up  
in the reaction. Potassium hydroxide is a strong caustic material and considerable care needs to be taken when  
preparing it. Here is the safety advice given by Bob Boyce, who is a most experienced and able builder of high-  
efficiency electrolysers and his instructions should be followed carefully in every respect when handling potassium  
hydroxide and preparing stainless steel for use in an electrolyser:

Mixing Potassium Hydroxide Solution  
Potassium hydroxide is also known as “caustic potash” and it is highly caustic. Consequently, it needs to be  
handled carefully and kept away from contact with skin, and even more importantly, eyes. If any splashes come  
in contact with you, it is very important indeed that the affected area be immediately rinsed off with large amounts  
of running water and if necessary, the use of vinegar which is acidic.

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S00495)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/495) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
