Bob Boyce uses a specially widened 48-inch belt sander which is good for preparing the plates using 60 or 80 grit.
However, most people don’t have this equipment and do the sanding by hand. Bob stresses that when doing
hand sanding the sandpaper is drawn across the plates in one direction only and not backwards and forwards, as
the backwards stroke always destroys the perfectly good ridges created on the forward stroke. Also, you only
need two strokes in one direction before turning the plate through ninety degrees and completing the sanding of
that face of the plate with just two more strokes (again, with no backstroke). Most people want to sand the
plates far too much and if overdone to a major degree, that can reduce the plate thickness and cause electrolyte
leakage through the slots around the plates. So, to say it again, to sand one face of a plate, use just two strokes
in one direction, turn the plate through ninety degrees and finish that face with just two more strokes, both in the
same direction.
Always wear rubber gloves when handling the plates to avoid getting finger marks on the plates. Wearing these
gloves is very important as the plates must be kept as clean and as grease-free as possible, ready for the next
stages of their preparation.
Any particles created by the sanding process should now be washed off the plates. This can be done with clean
tap water (not city water though, due to all the chlorine and other chemicals added), but only use distilled water for
the final rinse.
Following all the safety precautions for mixing electrolyte (in the Bob Boyce section), prepare a 5% to 10% NaOH
sodium hydroxide / lye solution (50 grams of NaOH in 950 cc water, to 100 g of NaOH in 900 cc of water ) and let
it cool down. Never handle the plates with your bare hands, but always use clean rubber gloves. Wind the plate
material into its spiral shape with two layers of 1/8” (3 mm) spacing material such as leather between the plates
and projecting well beyond one end. Wind the plates into the spiral shape (strictly speaking, a helix shape) and
slide them into a cut length of the plastic tube. The springy plates expand to press against the inside of the plastic
pipe. Pull the spacing material out slightly and start inserting 1/8” x 1/8” five inch long spacers between the
plates. Keep on pulling the spacing sheets out and pushing the spacing strips in until they are inserted the full
length of the plates.
Fill the electrolyser with the NaOH solution until the plates are covered. A voltage is now applied across the
whole set of plates by attaching the leads to the outermost two plates. This voltage should be at least 2 volts per
cell, but it should not exceed 2.5 volts per cell - for four pairs of spirals, this is 8 to 10 volts. Maintain this voltage
across the set of plates for several hours at a time. The current is likely to be 4 amps or more. As this process
continues, the boiling action will loosen particles from the pores and surfaces of the metal. This process produces
hydroxy gas, so it is very important that the gas is not allowed to collect anywhere indoors (such as on ceilings).
After several hours, disconnect the electrical supply and pour the electrolyte solution into a container. Rinse out
the cells thoroughly with distilled water. Filter the dilute NaOH solution through paper towels or coffee filters to
remove the particles. Pour the dilute solution back into the electrolyser and repeat this cleaning process. You
may have to repeat the electrolysis and rinsing process many times before the plates stop putting out particles
into the solution. If you wish, you can use a new NaOH solution each time you cleanse, but please realise that
you can go through a lot of solution just in this cleaning stage if you choose to do it that way. When cleansing is
finished (typically 3 days of cleansing), do a final rinse with clean distilled water.
Now, with thoroughly clean plates, the final conditioning process can be undertaken. Using the same
concentration of solution as in cleansing, fill the electrolyser with this dilute solution. Apply about 2 volts per cell
and allow the unit to run. Remember that very good ventilation is essential during this process. If the current
draw is fairly stable, continue with this conditioning phase continuously for two to three days, adding distilled water
to replace what is consumed. If the solution changes colour or develops a layer of crud on the surface of the
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.