---
canonical: "https://yogababe.online/reading/BATCH2-006/507"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 507 · 10 - 92 | Rejuvenati"
content_sha256: "e77ea366f107e8dba02de2390dd527b41ad92eac2161be822f646fb8b0121aa9"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 492 · section 507/1965 · approximately 5 minutes

## 10 - 92

10 - 92

The one-way valve shown between the two bubblers, is to prevent the water in the bubbler mounted beside the  
electrolyser, being driven into the electrolyser in the event of an explosion in the bubbler mounted beside the  
engine.

Bob Boyce’s Pulsed Electrolyser System  
The following section of this document describes Bob Boyce’s highly efficient pulsed electrolysis system. This  
has been very generously shared freely by Bob so that anyone who wishes may construct one for their own use  
without the payment of a licence fee or royalties. Just before presenting the details, it should be stressed that in  
order to get Bob’s performance of 600% to 1,200% of the Faraday (supposed) maximum gas output, each step  
needs to be carried out carefully exactly as described. Much of the following text is quoted from Bob’s forum  
posts and so should be considered as his copyright, not to be reproduced without his permission.

Your Responsibility:  
If you decide to construct an electrolyser of this, or any other design, you do so wholly on your own responsibility,  
and nobody is in any way liable for any loss or damage, whether direct or indirect, resulting from your actions. In  
other words, you are wholly responsible for what you choose to do. I say again, this document must not be  
construed as an encouragement for you to construct this or any other electrolyser.

Bob’s electrolyser splits water into a mixture of gases, mainly hydrogen and oxygen. That gas mixture, which will  
be referred to as “hydroxy” is highly explosive and must be treated with respect and caution. A fairly small volume  
of hydroxy gas exploded in air is quite liable to cause permanent hearing loss or impairment due to the shock  
waves caused by the explosion. If hydroxy gas is ignited inside a sealed container, then the resulting explosion is  
liable to shatter the container and propel shrapnel-like fragments in all directions. These fragments can cause  
serious injury and every precaution must be taken to ensure that an explosion of that nature never happens. Bob  
uses two bubblers and a one-way valve to protect against this occurrence, and details of these are given in this  
document.

To make the water inside the electrolyser carry the necessary current, potassium hydroxide (KOH) is added to  
distilled water. This is the best electrolyte for an electrolyser of this type. Potassium hydroxide is also known as  
“caustic potash” and it is highly caustic, as is NaOH – sodium hydroxide. Consequently, they both need to be  
handled carefully and kept away from contact with skin, and even more importantly, eyes. If any splashes come  
in contact with you, it is very important indeed that the affected area be immediately rinsed off with large amounts  
of running water and if necessary, the use of vinegar which is acidic.

This electrolyser design uses a toroidal transformer to interface the electronics to the electrolyser cells. It is vital  
that this transformer be used very carefully. Under no circumstances may this transformer be powered up by the  
electronics when connected to anything other than the filled electrolyser cells as they act as a safety buffer.  
When driven by Bob’s electronics, this transformer draws additional energy from the environment. While this is  
very useful for electrolysis, there are sometimes unpredictable energy surges which can generate as much as  
10,000 amps of current. If one of these should occur when the transformer is not connected to the electrolyser  
which is able to soak up this excess, the resulting electrical conditions can be very serious. If you are lucky, it will  
just burn out expensive components. If you are not lucky, it can cause a lightning strike which is liable to hit you.  
For that reason, it is absolutely essential that the toroid transformer is never powered up with the secondary  
winding connected to anything other than the filled electrolyser.

Patenting:  
It should be clearly understood that Bob Boyce, has released this information into the public domain and it has  
been displayed publicly since early in 2006. It is not possible for any part of this information to be made part of  
any patent application anywhere in the world. This prior public disclosure of the information prevents it being  
patented. It is Bob’s intention that this information be freely available to people world-wide. It should also be  
emphasised that all of the quotations of Bob’s words which forms an extensive part of this document, remain the  
copyright of Bob and may not be reproduced for display or sale without his prior written permission.

The Objective:  
This is a “Hydroxy-On-Demand” (“HOD”) system. It is very difficult indeed to generate hydroxy gas fast enough to  
power an internal combustion engined vehicle under all road conditions. Moving from standstill to rapid  
acceleration causes such a massive sudden requirement for additional volumes of hydroxy gas, that it is difficult  
to provide that volume instantly.

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S00507)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/507) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
