REJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITY

science · SOURCE BATCH2-006

A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

Open first-party PDF viewer

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

Contents and coverage · All reading editions · Explanatory guides · Source metadata

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Full commentary and investigation questions

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 506 · section 521/1965 · approximately 4 minutes

10 - 106

10 - 106
Terminal Block TB1 has 4 connections as follows;

1. DC Input + is connected to the 13.8 V DC power supply positive connection via a 2-amp fuse or circuit breaker.

2. DC Input - is connected to the 13.8 V DC power supply negative connection. If a shorting plug is installed at
J3, this wire is optional.

3. and 4. Ground is connected to the 13.8 V DC power supply negative connection via heavy gauge wire. There
are two wire connection terminals available so that two equal length wires may be used to reduce wire
resistance losses.

Terminal BlockTB2 has 4 connections which are connected as follows:

Gate + is not normally connected when a shorting plug is installed at jumper J2.
Output 1 is connected to the “cold” side of primary 1 of the toroidal transformer.
Output 2 is connected to the “cold” side of primary 2 of the toroidal transformer.
Output 3 is connected to the “cold” side of primary 3 of the toroidal transformer.

The “hot” sides of primaries 1, 2, and 3 are brought together, and connected to the 13.8 V DC power supply
positive connection via heavy-gauge wire and a 60-amp fuse or DC circuit-breaker.

Note: These fuses are for short circuit protection, and are not an indication of system power consumption.

Testing the completed board:
Do NOT connect the PWM3G outputs to a powered transformer until after the unit tests show it to be fully
functional. You may pull the 60-amp fuse out, or trip the DC circuit-breaker, while testing and tuning.

Power up the PWM3G board and check the indicator LEDs for proper operation:

LED 1 - the Channel 1 output - should be lit in normal operation, off if disabled.
LED 2 - the Channel 2 output - should be lit in normal operation, off if disabled.
LED 3 - the Channel 3 output - should be lit in normal operation, off if disabled.

LED 4 - the PWM channel 1 disable - should be off in normal operation, on if disabled.
LED 5 - the PWM channel 2 disable - should be off in normal operation, on if disabled.
LED 6 - the PWM channel 3 disable - should be off in normal operation, on if disabled.

LED 7 - the 12 volt supply - should be lit in normal operation, off when powered down.
LED 8 - the 8 volt supply - should be lit when the power is connected and off when powered down.

If all indicators check out, then start the tuning procedure. If everything checks out ok except the output indicators,
then try tuning first then test again. Failures may indicate component or soldering problems.

Tuning the board:
Adjust all 3 of the "DC" marked (Duty Cycle) potentiometers (R25, R27, R29) fully clockwise, for minimum pulse
width.

Connect a frequency counter or oscilloscope to Jumper J4 pin 1 (Aux Input 3) and adjust the channel 3 "Hz"
marked potentiometer (R28) for a reading of 10.7 KHz.

Connect a frequency counter or oscilloscope to Jumper J4 pin 2 (Aux Input 2) and adjust the channel 2 "Hz"
marked potentiometer (R26) for a reading of 21.4 KHz.

Connect a frequency counter or oscilloscope to Jumper J4 pin 3 (Aux Input 1) and adjust the channel 1 "Hz"
marked potentiometer (R24) for a reading of 42.8 KHz.

Note: If channel 1 shuts down while tuning towards 42.8 KHz, replace U1 with a different brand of NE556 type
timer chip. Many of these chips, like those marked as made in Taiwan, do not fully meet the NE555 spec and will
shut down with the output turned on solid. If this occurs while loaded, the output FET for that channel may be

This full section as JSON

Congratulations. You’ve won a support ticket.

Your prize is an email address. No purchase required—but coffee helps keep this place online.

Open a support ticket: azmin@zedec.ai

Support and privacy requests are free. Response times are not guaranteed.

The ceremonial small print

“Due to unusual call volume and support volume, we are experiencing longer than normal wait times for a response.” This is our satirical holding message, not a measured queue report. We offer email support.

America runs on coffee, Britain puts the kettle on, and the opium trade reminds us that empires have had considerably worse business plans.

Donation is optional. No prize draw, purchase verification or guaranteed response is involved. Mandatory legal response duties still apply.

Public-interest research, not a spy drop. We keep 18 U.S.C. § 793 on the reading list—and restricted material off the guest list.

Site support and inquiries are welcome: azmin@zedec.ai. We reserve the right to remain silent, subject to legally required responses.