Terminal Block TB1 has 4 connections as follows;
1. DC Input + is connected to the 13.8 V DC power supply positive connection via a 2-amp fuse or circuit breaker.
2. DC Input - is connected to the 13.8 V DC power supply negative connection. If a shorting plug is installed at
J3, this wire is optional.
3. and 4. Ground is connected to the 13.8 V DC power supply negative connection via heavy gauge wire. There
are two wire connection terminals available so that two equal length wires may be used to reduce wire
resistance losses.
Terminal BlockTB2 has 4 connections which are connected as follows:
Gate + is not normally connected when a shorting plug is installed at jumper J2.
Output 1 is connected to the “cold” side of primary 1 of the toroidal transformer.
Output 2 is connected to the “cold” side of primary 2 of the toroidal transformer.
Output 3 is connected to the “cold” side of primary 3 of the toroidal transformer.
The “hot” sides of primaries 1, 2, and 3 are brought together, and connected to the 13.8 V DC power supply
positive connection via heavy-gauge wire and a 60-amp fuse or DC circuit-breaker.
Note: These fuses are for short circuit protection, and are not an indication of system power consumption.
Testing the completed board:
Do NOT connect the PWM3G outputs to a powered transformer until after the unit tests show it to be fully
functional. You may pull the 60-amp fuse out, or trip the DC circuit-breaker, while testing and tuning.
Power up the PWM3G board and check the indicator LEDs for proper operation:
LED 1 - the Channel 1 output - should be lit in normal operation, off if disabled.
LED 2 - the Channel 2 output - should be lit in normal operation, off if disabled.
LED 3 - the Channel 3 output - should be lit in normal operation, off if disabled.
LED 4 - the PWM channel 1 disable - should be off in normal operation, on if disabled.
LED 5 - the PWM channel 2 disable - should be off in normal operation, on if disabled.
LED 6 - the PWM channel 3 disable - should be off in normal operation, on if disabled.
LED 7 - the 12 volt supply - should be lit in normal operation, off when powered down.
LED 8 - the 8 volt supply - should be lit when the power is connected and off when powered down.
If all indicators check out, then start the tuning procedure. If everything checks out ok except the output indicators,
then try tuning first then test again. Failures may indicate component or soldering problems.
Tuning the board:
Adjust all 3 of the "DC" marked (Duty Cycle) potentiometers (R25, R27, R29) fully clockwise, for minimum pulse
width.
Connect a frequency counter or oscilloscope to Jumper J4 pin 1 (Aux Input 3) and adjust the channel 3 "Hz"
marked potentiometer (R28) for a reading of 10.7 KHz.
Connect a frequency counter or oscilloscope to Jumper J4 pin 2 (Aux Input 2) and adjust the channel 2 "Hz"
marked potentiometer (R26) for a reading of 21.4 KHz.
Connect a frequency counter or oscilloscope to Jumper J4 pin 3 (Aux Input 1) and adjust the channel 1 "Hz"
marked potentiometer (R24) for a reading of 42.8 KHz.
Note: If channel 1 shuts down while tuning towards 42.8 KHz, replace U1 with a different brand of NE556 type
timer chip. Many of these chips, like those marked as made in Taiwan, do not fully meet the NE555 spec and will
shut down with the output turned on solid. If this occurs while loaded, the output FET for that channel may be
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.