---
canonical: "https://yogababe.online/reading/BATCH2-006/526"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 526 · 10 - 111 | Rejuvenati"
content_sha256: "359201117d0896df21e397e7b1cfea9765524adef007680e194187813d228725"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 511 · section 526/1965 · approximately 5 minutes

## 10 - 111

10 - 111  
Please note that every winding starts by passing over the toroid, proceeds in a counter-clockwise direction, and  
finishes by passing under the toroid. Every winding is created in this way and the quality of workmanship is very  
important indeed when making these windings. Each winding needs to be tight and positioned exactly with turns  
touching each other in the centre of the toroid and positioned on the outer edge with exactly equal spaces  
between each turn. Your construction work has to be better than that of a commercial supplier and needs to  
reach the quality demanded by the military, which would cost thousands of dollars for each toroid if it were to be  
made up for you by professionals.

The three primaries need to be wound on top of the tape wrapping which covers the secondary winding. These  
three windings are spaced out equally around the toroid, that is, at 120 degree centres. The leads of the  
secondary winding exit through the gap between two of the primary windings. The primary windings are held in  
place with beeswax, and then tightly taped. The primaries may need more than a single layer, and they are  
wound with the same direction of winds as the secondary, and the same care for even winding spacing as the  
secondary needed. Tape the entire core well with tightly-stretched PVC electrical tape after winding, to ensure  
that the primary windings do not move and then add an outer layer of winding tape. Bob uses the 1P802YE type  
on 3" rolls, both the 1" and 2" widths from:  
[http://www.lodestonepacific.com/distrib/pdfs/tape/1p802.pdf](http://www.lodestonepacific.com/distrib/pdfs/tape/1p802.pdf)

This is where the generic information ends. The exact details of the primary windings must be determined from  
the operational characteristics of the cells. This means that you must build, cleanse and condition your cells prior  
to making the operational measurements. This is done as follows: After full plate cleansing as described earlier,  
condition the plates until the cell stack reaches at least 150% but ideally 200% or more of Faraday’s maximum  
power efficiency (2.34 Watt-Hours per Litre per Hour). Then, allow the cell stack to cool to room temperature.  
The cell stack is then powered up with a variable-voltage power supply and the voltage adjusted until the cell  
current is exactly 2 amps. Write down the voltage needed to give this 2 amp current flow, and do it promptly  
before the cell starts to warm up again.

The objective here is to have the complex waveform generated by the electronics, produce voltages of about 25%  
of this measured voltage, so divide your measured voltage by four. The output from the electronics board is about  
12.5 volts, so divide again by 12.5 to get the turns-ratio for the toroidal transformer. This is normally in the range  
of 3.0 to 3.5 and that means that the secondary winding needs to have that times as many turns in it as each  
primary winding does.

For example, (and example only) say your measured voltage happens to be 155 volts. Then the turns ratio would  
be 155 divided by 4 which is 38.75, and then divide that by 12.5 which gives 3.1 which is the turns ratio. If your  
secondary winding has, say, 134 turns in it, then the number of turns in each of the three primary windings would  
be 134 / 3.1 which is 43.23 turns. Round this upwards to give 44 turns.

If the number of turns which you use is off by one turn, then the tuning of the electronics board can compensate  
for it. If the number of primary turns is off by two turns, then it is possible that you might just be able to  
compensate for the error by tuning the board, but it is unlikely that you will. If the number of turns is three or more  
away from the optimum number calculated, then the impedance of the primary windings will be too far out for the  
board to tune it.

Normally, the diameter of the wire used in the primaries will be greater than that of the secondary because it will  
be driven by a much lower voltage and so will need a much higher current, but that is not the case here. Now that  
you have cleansed and conditioned the plates in your electrolyser, power up your inverter with your vehicle engine  
running at 2000 rpm or so, and measure the DC current taken by the inverter. This is the level of current which  
the primary windings have to carry, so the wire size can be selected from this measurement. Each primary  
winding is pulsed, so it is not carrying current all of the time, also, the final primary current is the sum of the three  
pulsing signals, so a reduction can be allowed for that. While the wire diameter for the primary windings of each  
toroidal transformer need to be calculated separately, a common diameter turns out to be AWG #20 (21 SWG).  
The wire length for the primaries will be greater per turn as the turns are now being made over the secondary  
winding. Forty-eight turns of #20 wire are likely to require at least thirty-five feet and that is for each of the three  
windings, assuming that all turns can be laid flat side-by-side. If it is necessary to make each a two-layer winding,  
then the wire length will increase further.

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S00526)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/526) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
