canonical: "https://yogababe.online/reading/BATCH2-006/528"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 528 · 10 - 112 | Rejuvenati"
content_sha256: "0e835059360fa40d71edd2a70a0fb5ca1a640489b97442bb0439e01859238871"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 512 · section 528/1965 · approximately 4 minutes

## 10 - 112

10 - 112

Power Limits:  
At the present time, the largest available iron-powder toroid commercially available is the Micrometals 6.5" unit.  
This sets the upper power limit for a Bob Boyce design electrolyser at 32 square inches of plate area. Bob’s  
present design uses six inch square plates, but the electrolyte level is maintained at just three inches and some  
area is effectively lost where the plates enter the walls and base of the housing. This 101-plate unit, when built  
with precision and conditioned and tuned correctly, can generate 50 lpm continuously and short bursts of up to  
100 lpm. That is about one litre per minute of hydroxy gas per cell. This should be sufficient to run an internal  
combustion engine with a one litre engine capacity, but engines vary so much, that there can be no rule of thumb  
for the gas production rate needed for a given engine size.

The optimum operating voltage for his 101-plate electrolyser has been established by Bob as being 1.5 volts per  
cell. However, the power limitation of the 6.5 inch toroid does not prevent the voltage being raised. So, if we opt  
for using a 220 volt inverter rather than the 110 volt one already described, then the number of cells can be  
doubled. This extends the case from about twenty inches in length to around forty inches. This might be suitable  
for use with vehicles up to two litre engine capacity and the unit can be located on the flatbed of a truck or the  
boot (trunk) of a car or beside a generator if it is being used to power an electrical generator. Electrical generator  
engines are usually incredibly inefficient with an overall efficiency of as little as 10% when the generator is  
considered. Consequently, running a generator on hydroxy gas alone is by no means as easy as it looks on the  
surface. If an electrolyser is installed in a vehicle, it is very important that no pipe carrying hydroxy gas is routed  
through any passenger area and a bubbler positioned close to the engine. The number one priority must always  
be safety.

Bob Boyce says: "I use a GE whole house water filter housing from Home Depot as the housing, costing just  
under $20. Inside it, I use an Ace Hardware 1 micron sediment filter element, which I force-submerge and soak in  
water for a few days prior to use. A pack of two costs just under $10. Do not be tempted to use the 5-15 micron  
sediment filters sold by both Home Depot and Ace Hardware for a few dollars less. Saving money here is  
NOT the right place to try to be cheap as the very health of your engine may rely on this filter if anything happens  
to your bubbler."

Increased gas output can be got by increasing the width of the plates while maintaining the plate area covered by  
the electrolyte. One possibility is to make the plates nine inches wide and keeping the electrolyte at a four-inch  
depth, giving thirty-six square inches of plate area. The plate size would then be 9” x 6” or any other height up to  
9” x 9”.

The reason why a Boyce electrolyser can give 1,200% of the maximum possible gas output determined by  
Michael Faraday, is that this unit pulls in large amounts of additional power from the environment. So, the vehicle  
electrics is used primarily to power the pulsed toroidal circuitry which taps this energy, and the conversion of  
water to hydroxy gas is performed primarily by energy drawn from the environment.

Plate surface preparation is very important and is described in detail. However, the way that the plates operate  
when used for straight DC electrolysis is quite different from the way that they operate when being used in high-  
efficiency pulsed-mode: