Source page 513 · section 529/1965 · approximately 2 minutes
10 - 113
10 - 113
With straight DC-electrolysis, the bubbles of hydroxy gas form on the face of the plates and break away, helped
by the thousands of microscopic, sharp-peaked mountains created on the face of every plate by the two-direction
scoring with sandpaper. With the pulsed technique, the hydroxy bubbles form in the electrolyte itself, between
the plates and give the visual impression of the electrolyte boiling.
It should be realised that with the large gas volumes produced with the 101-plate and 201-plate electrolysers, that
a considerable pipe diameter is needed to carry the gas, and even more importantly, the two bubblers used need
to be a considerable size. It is important that the bubbles streaming up through the water in the bubbler do not
form a continuous column of hydroxy gas as that could carry a flame straight through the bubbler and defeat the
protection which it normally provides. A good technique to combat this and improve the scrubbing of electrolyte
fumes out of the gas, is to put a large number of small holes in the sides of the pipe carrying the gas down into the
water in the bubbler. This creates a large number of smaller bubbles and is much more effective.
Connecting the Electrics:
Bob has specified that the primary windings are connected between the board outputs and the positive supply for
the board like this:
In the above diagram, two 200-volt 470 microfarad capacitors are used to smooth the pulsing DC waveform
coming from the diode bridge. Their inclusion will have a considerable effect on the waveform. It is important to
include heavy-duty chokes (coils) in both sides of the high voltage power supply and in the 13.8 volt positive lead
coming from the vehicle electrics. The recommended choke cores are the MicroMetals T157-45 and these are
wound with 15 turns of AWG #16 (SWG 18) enamelled copper wire, through it is perfectly ok to wind these chokes
on laminated iron pieces taken from the frame of an old mains power transformer. These fifteen turns give an
inductance of 29.5 microhenrys.
If all is well and the 20-amp contact-breaker (or fuse) is not tripped, the electrical power passes through to the
gas-pressure switch mounted on the electrolyser. If the gas production rate is greater than the engine
requirement and as a result, the gas pressure inside the electrolyser gets above 5 psi. then the gas pressure
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.