---
canonical: "https://yogababe.online/reading/BATCH2-006/531"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 531 · 10 - 115 | Rejuvenati"
content_sha256: "18d4e1ec135ce8faa0aeaa96a90a31a810d0b50adebabe22a0bb1a95b0b26ec6"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 515 · section 531/1965 · approximately 3 minutes

## 10 - 115

10 - 115

Supplying the Water:  
The potassium hydroxide is not used up when the electrolyser is operated. A small amount leaves the  
electrolyser in the form of vapour but this is washed out of the gas in the first bubbler. Two bubblers are used, the  
first is located beside the electrolyser and connected to it via a one-way valve. The second bubbler is located  
close to the engine. From time to time, the water in the bubblers is poured back into the electrolyser and that  
prevents the loss of any potassium hydroxide. Not only does this conserve the potassium hydroxide, but it also  
protects the engine as potassium hydroxide has a very bad effect inside the engine itself.

The overall water system is like this in broad outline, omitting the electrical safety devices:

A probe inside the electrolyser senses when the average level of the electrolyte has dropped and powers up the  
water pump to inject more water into the electrolyser. The rate of gas production is so high with the pulsed  
system that the electrolyte level is place at about half the plate height. That is some three inches below the tops  
of the plates. Because of this violent action, the water-level sensor needs to be operated from the electrolyte  
outside the plates where the surface of the electrolyte does not move so violently.

A serious issue with an electrolyser of this type is dealing with water loss. As the plates have to be spaced  
closely together and the since the electrolyte between the cells is effectively isolated from the electrolyte in the  
other cells, driving a mile down the road is liable to lower the water level by half an inch (say, one centimetre). It  
is essential to keep replacing the water which is used.

Two things have to be dealt with:

1\. Sensing when the electrolyte level has fallen, and  
2\. Creating some device for getting extra water into each cell

Simple electronics provides the answer to sensing the level of the electrolyte, and a windscreen-washer water  
pump can be used to inject the additional water.

A sensor for the water in the cells can be on just one cell. If the water level of any one cell falls below the level in  
the other cells, then the gas produced in that cell will be slightly less than the other cells, so it will lose less water  
until the water levels match again. Also, Bob recommends cutting the slots which hold the plates, 3 ten  
thousandths of an inch (0.0003” or 0.0075 mm) larger than the actual thickness of the metal plates. This  
effectively blocks electrical leakage between adjacent cells but does allow a very gradual migration of electrolyte  
between the cells to help maintain an even electrolyte surface across the cell.

The water-level sensor can be just one stiff stainless steel wire run down each side of any cell. These wires  
should be insulated to make sure that they do not short-circuit to either (or both) of the plates on each side of  
them. They should be set so that their tips are at the intended surface level of the electrolyte.

If the electrolyte level drops below the tip of the wire sensors, then the resistance between the wires will fall,  
indicating that more water is needed. This can switch the water pump on, which will raise the water level until the  
electrolyte level reaches the tip of the wire again. A possible circuit for doing this is shown here:

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S00531)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/531) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
