To combat splashing of the electrolyte, a layer of aquarium matting is placed over the tops of the plates. Anti-
slosh matting will act like a sponge and hold electrolyte against the tops of the plates, shorting out the series cells
end to end. So we must make sure that if that sort of filter media is used, it must be kept away from the plates.
Bob uses woven plastic washable air filter media designed for commercial HVAC systems. This comes in sheets
which are 24" x 36" x 1" which are then cut to size. He buys these from the HVAC division of Wholesale Supply
Group, Cleveland TN. As long as you have a good layer of that stiff / coarse filter media over the plates, you can
then fill in above that with a denser media such as polyfill or something similar. This can be found at crafts supply
stores in sheets or loose wads of fibre, as stuffing for bedding or pillows, or it can be got from pet supply stores
where it is supplied as aquarium filter material.
In the diagram above, only a few of the 101 plates are shown, in order to keep the drawing narrow enough to fit
on the page. The plates at each end have a stainless steel strap welded to them in order to allow for simple and
robust electrical connections to be made through the case.
The water supply is arranged to feed equal amounts of water to each cell. The design for this supply pipe has
recently been improved by Ed Holdgate and Tom Thayer and Ed now supplies one along with the precision
housings which he makes for Bob’s design. The new design has a water-supply pipe with very accurately cut
slots in it. The lengths of the slots are directly related to how far along the pipe they are positioned. The objective
is to have the same amount of water coming out of each slot even though the water pressure drops the further
along the pipe the slot is located.
That water supply pipe is then housed in an outer pipe which has a hole drilled in it exactly above each of the
bodies of electrolyte trapped between the plates (a 3/16” spacing):
This water supply pipe arrangement works well in practice and it looks surprisingly like the gas take-off pipe which
has a series of holes drilled along the top of it:
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.